Cargando…
Dual-layer spectral detector computed tomography parameters can improve diagnostic efficiency of lung adenocarcinoma grading
BACKGROUND: It is difficult to distinguish the pathological grade of lung adenocarcinoma (LUAD) with traditional computed tomography (CT). The aim of this study was to assess tumor differentiation by dual-layer spectral detector CT combined with morphological parameters. METHODS: In this prospective...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
AME Publishing Company
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9403580/ https://www.ncbi.nlm.nih.gov/pubmed/36060598 http://dx.doi.org/10.21037/qims-22-2 |
_version_ | 1784773409030275072 |
---|---|
author | Mu, Ronghua Meng, Zhuoni Guo, Zixuan Qin, Xiaoyan Huang, Guangyi Yang, Xuri Jin, Hui Yang, Peng Zhang, Xiaodi Zhu, Xiqi |
author_facet | Mu, Ronghua Meng, Zhuoni Guo, Zixuan Qin, Xiaoyan Huang, Guangyi Yang, Xuri Jin, Hui Yang, Peng Zhang, Xiaodi Zhu, Xiqi |
author_sort | Mu, Ronghua |
collection | PubMed |
description | BACKGROUND: It is difficult to distinguish the pathological grade of lung adenocarcinoma (LUAD) with traditional computed tomography (CT). The aim of this study was to assess tumor differentiation by dual-layer spectral detector CT combined with morphological parameters. METHODS: In this prospective study, a total of 67 patients with pathologically diagnosed LUAD were enrolled: 39 patients in the well- and moderately-differentiated group (14 and 25 patients, respectively) and 28 patients in the poorly-differentiated group. Morphological parameters, non-enhanced CT number, double-enhanced CT number, effective atomic number, monoenergetic CT images (40 and 70 keV), iodine density, and thoracic aorta iodine density of tumors were measured. The slope of the spectral curve and normalized iodine density were calculated. The diagnostic efficiency of the spectral parameters alone, and the combined spectral and morphological parameters were obtained by statistical analysis. RESULTS: The morphological signs of LUAD (the vessel convergence sign, bronchus encapsulated air sign, and liquefactive necrosis) were higher in the poorly-differentiated group than in the well–moderately-differentiated group (57.1% vs. 30.8%, 40.0%; 60.7% vs. 28.2%, 32.0%; 64.3% vs. 28.2%, 24.0%; all P<0.05). There were significant differences in normalized iodine density (arterial phase: 0.10±0.04 vs. 0.12±0.05, 0.13±0.04; venous phase: 0.31±0.07 vs. 0.39±0.17, 0.40±0.17) among the poorly-differentiated group and moderately-differentiated group as well as the well-differentiated group (all P<0.05). Receiver operating characteristic (ROC) curves of the poorly-differentiated group and well–moderately-differentiated group showed that the normalized iodine density had the best diagnostic efficiency in the arterial phase, with an area under the curve (AUC) of 0.817, sensitivity of 92.9%, and specificity of 82.1% (P<0.001). The AUC increased to 0.916 when the morphological parameters were included, and sensitivity and specificity were 96.4% and 82.1% (P<0.001), respectively. CONCLUSIONS: The parameters of dual-layer spectral detector CT can help discriminate the pathological grade of LUAD. Among the spectral parameters, the normalized iodine density in the arterial phase has the best diagnostic efficiency, and the combination of spectral and morphological parameters improves the pathological grading of LUAD. |
format | Online Article Text |
id | pubmed-9403580 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | AME Publishing Company |
record_format | MEDLINE/PubMed |
spelling | pubmed-94035802022-09-01 Dual-layer spectral detector computed tomography parameters can improve diagnostic efficiency of lung adenocarcinoma grading Mu, Ronghua Meng, Zhuoni Guo, Zixuan Qin, Xiaoyan Huang, Guangyi Yang, Xuri Jin, Hui Yang, Peng Zhang, Xiaodi Zhu, Xiqi Quant Imaging Med Surg Original Article BACKGROUND: It is difficult to distinguish the pathological grade of lung adenocarcinoma (LUAD) with traditional computed tomography (CT). The aim of this study was to assess tumor differentiation by dual-layer spectral detector CT combined with morphological parameters. METHODS: In this prospective study, a total of 67 patients with pathologically diagnosed LUAD were enrolled: 39 patients in the well- and moderately-differentiated group (14 and 25 patients, respectively) and 28 patients in the poorly-differentiated group. Morphological parameters, non-enhanced CT number, double-enhanced CT number, effective atomic number, monoenergetic CT images (40 and 70 keV), iodine density, and thoracic aorta iodine density of tumors were measured. The slope of the spectral curve and normalized iodine density were calculated. The diagnostic efficiency of the spectral parameters alone, and the combined spectral and morphological parameters were obtained by statistical analysis. RESULTS: The morphological signs of LUAD (the vessel convergence sign, bronchus encapsulated air sign, and liquefactive necrosis) were higher in the poorly-differentiated group than in the well–moderately-differentiated group (57.1% vs. 30.8%, 40.0%; 60.7% vs. 28.2%, 32.0%; 64.3% vs. 28.2%, 24.0%; all P<0.05). There were significant differences in normalized iodine density (arterial phase: 0.10±0.04 vs. 0.12±0.05, 0.13±0.04; venous phase: 0.31±0.07 vs. 0.39±0.17, 0.40±0.17) among the poorly-differentiated group and moderately-differentiated group as well as the well-differentiated group (all P<0.05). Receiver operating characteristic (ROC) curves of the poorly-differentiated group and well–moderately-differentiated group showed that the normalized iodine density had the best diagnostic efficiency in the arterial phase, with an area under the curve (AUC) of 0.817, sensitivity of 92.9%, and specificity of 82.1% (P<0.001). The AUC increased to 0.916 when the morphological parameters were included, and sensitivity and specificity were 96.4% and 82.1% (P<0.001), respectively. CONCLUSIONS: The parameters of dual-layer spectral detector CT can help discriminate the pathological grade of LUAD. Among the spectral parameters, the normalized iodine density in the arterial phase has the best diagnostic efficiency, and the combination of spectral and morphological parameters improves the pathological grading of LUAD. AME Publishing Company 2022-09 /pmc/articles/PMC9403580/ /pubmed/36060598 http://dx.doi.org/10.21037/qims-22-2 Text en 2022 Quantitative Imaging in Medicine and Surgery. All rights reserved. https://creativecommons.org/licenses/by-nc-nd/4.0/Open Access Statement: This is an Open Access article distributed in accordance with the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 International License (CC BY-NC-ND 4.0), which permits the non-commercial replication and distribution of the article with the strict proviso that no changes or edits are made and the original work is properly cited (including links to both the formal publication through the relevant DOI and the license). See: https://creativecommons.org/licenses/by-nc-nd/4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) . |
spellingShingle | Original Article Mu, Ronghua Meng, Zhuoni Guo, Zixuan Qin, Xiaoyan Huang, Guangyi Yang, Xuri Jin, Hui Yang, Peng Zhang, Xiaodi Zhu, Xiqi Dual-layer spectral detector computed tomography parameters can improve diagnostic efficiency of lung adenocarcinoma grading |
title | Dual-layer spectral detector computed tomography parameters can improve diagnostic efficiency of lung adenocarcinoma grading |
title_full | Dual-layer spectral detector computed tomography parameters can improve diagnostic efficiency of lung adenocarcinoma grading |
title_fullStr | Dual-layer spectral detector computed tomography parameters can improve diagnostic efficiency of lung adenocarcinoma grading |
title_full_unstemmed | Dual-layer spectral detector computed tomography parameters can improve diagnostic efficiency of lung adenocarcinoma grading |
title_short | Dual-layer spectral detector computed tomography parameters can improve diagnostic efficiency of lung adenocarcinoma grading |
title_sort | dual-layer spectral detector computed tomography parameters can improve diagnostic efficiency of lung adenocarcinoma grading |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9403580/ https://www.ncbi.nlm.nih.gov/pubmed/36060598 http://dx.doi.org/10.21037/qims-22-2 |
work_keys_str_mv | AT muronghua duallayerspectraldetectorcomputedtomographyparameterscanimprovediagnosticefficiencyoflungadenocarcinomagrading AT mengzhuoni duallayerspectraldetectorcomputedtomographyparameterscanimprovediagnosticefficiencyoflungadenocarcinomagrading AT guozixuan duallayerspectraldetectorcomputedtomographyparameterscanimprovediagnosticefficiencyoflungadenocarcinomagrading AT qinxiaoyan duallayerspectraldetectorcomputedtomographyparameterscanimprovediagnosticefficiencyoflungadenocarcinomagrading AT huangguangyi duallayerspectraldetectorcomputedtomographyparameterscanimprovediagnosticefficiencyoflungadenocarcinomagrading AT yangxuri duallayerspectraldetectorcomputedtomographyparameterscanimprovediagnosticefficiencyoflungadenocarcinomagrading AT jinhui duallayerspectraldetectorcomputedtomographyparameterscanimprovediagnosticefficiencyoflungadenocarcinomagrading AT yangpeng duallayerspectraldetectorcomputedtomographyparameterscanimprovediagnosticefficiencyoflungadenocarcinomagrading AT zhangxiaodi duallayerspectraldetectorcomputedtomographyparameterscanimprovediagnosticefficiencyoflungadenocarcinomagrading AT zhuxiqi duallayerspectraldetectorcomputedtomographyparameterscanimprovediagnosticefficiencyoflungadenocarcinomagrading |