超高效液相色谱-静电场轨道阱高分辨质谱法测定硝苯地平中痕量基因毒性杂质

A method based on ultra high performance liquid chromatography-electrostatic field orbitrap high resolution mass spectrometry (UHPLC-Orbitrap HRMS) was established for the determination of genotoxic impurities 2, 6, and 12 in nifedipine. After extraction with methanol, the sample was injected into t...

Descripción completa

Detalles Bibliográficos
Autores principales: GUO, Changchuan, TAN, Huijie, LIU, Qi, GONG, Tengfei, WANG, Xue, WANG, Chenglin, XU, Yuwen
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Editorial board of Chinese Journal of Chromatography 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9404017/
https://www.ncbi.nlm.nih.gov/pubmed/35243836
http://dx.doi.org/10.3724/SP.J.1123.2021.06008
_version_ 1784773516024872960
author GUO, Changchuan
TAN, Huijie
LIU, Qi
GONG, Tengfei
WANG, Xue
WANG, Chenglin
XU, Yuwen
author_facet GUO, Changchuan
TAN, Huijie
LIU, Qi
GONG, Tengfei
WANG, Xue
WANG, Chenglin
XU, Yuwen
author_sort GUO, Changchuan
collection PubMed
description A method based on ultra high performance liquid chromatography-electrostatic field orbitrap high resolution mass spectrometry (UHPLC-Orbitrap HRMS) was established for the determination of genotoxic impurities 2, 6, and 12 in nifedipine. After extraction with methanol, the sample was injected into the UHPLC-Orbitrap HRMS system for analysis. An ACE EXCEL(TM) 3 C18-AR column (150 mm×4.6 mm, 3 μm) was used for chromatographic separation. The mobile phase was methanol-0.1% formic acid aqueous solution (65:35, v/v). The flow rate was 0.6 mL/min, while the column temperature and autosampler temperature were set as 35 ℃ and 8 ℃, respectively. The divert valve switching technique was used to protect the mass spectrometer. The six-way valve was set to divert the eluent of 7.5-11.6 min to waste and the rest of the eluent into the mass spectrometer. The Orbitrap mass spectrometer was coupled with the UHPLC system by an electrospray ion (ESI) source. The sheath gas and auxiliary gas flow rates were 60 and 20 arb (arbitrary units), respectively. The spray voltage was 3.5 kV, while the capillary temperature and auxiliary gas heater temperature were set as 350 ℃ and 400 ℃, respectively. The positive ion parallel reaction monitoring (PRM) scanning mode was adopted, and the mass spectral resolution was set to 35000 FWHM. The accurate masses of the [M+H](+) precursor ions of impurities 2, 6, and 12 were m/z 347.1230, 361.1026, and 347.1230, respectively. The accurate masses of the extracted [M+H](+) fragment ions of impurities 2, 6, and 12 were m/z 315.0968, 298.1069, and 315.0968, respectively. The normalized collision energies (NCEs) were optimized to 10%, 42%, and 10% for impurities 2, 6, and 12, respectively. The external standard method was utilized for quantitative analysis. The established method was validated in detail by investigating the specificity, linear range, limit of detection (LOD), limit of quantification (LOQ), recovery, precision, and stability. This method had good specificity, and the solvent did not interfere with the determination of impurities. The peak areas of impurities 2, 6, and 12 as well as their concentrations showed good linear relationships in the ranges of 0.2-100 ng/mL, with all correlation coefficients (r)≥0.9998. The recoveries of impurities 2, 6, and 12 at three levels (low, medium, and high) were in the range of 96.9%-105.0%, while the RSDs were between 1.21% and 5.12%. The LODs were 0.05 ng/mL and the LOQs were 0.2 ng/mL for all three impurities. This analytical method was used to determine impurities 2, 6, and 12 in three batches of nifedipine samples. Impurity 6 was not detected in the three batches, but impurities 2 and 12 were detected in all the three samples, and the detection amount was within the limit. The developed method is sensitive, fast, accurate, and easy to operate. It can provide a reference for the quality control of nifedipine by pharmaceutical companies and extend strong technical support for the supervision by drug regulatory authorities.
format Online
Article
Text
id pubmed-9404017
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Editorial board of Chinese Journal of Chromatography
record_format MEDLINE/PubMed
spelling pubmed-94040172022-09-14 超高效液相色谱-静电场轨道阱高分辨质谱法测定硝苯地平中痕量基因毒性杂质 GUO, Changchuan TAN, Huijie LIU, Qi GONG, Tengfei WANG, Xue WANG, Chenglin XU, Yuwen Se Pu Articles A method based on ultra high performance liquid chromatography-electrostatic field orbitrap high resolution mass spectrometry (UHPLC-Orbitrap HRMS) was established for the determination of genotoxic impurities 2, 6, and 12 in nifedipine. After extraction with methanol, the sample was injected into the UHPLC-Orbitrap HRMS system for analysis. An ACE EXCEL(TM) 3 C18-AR column (150 mm×4.6 mm, 3 μm) was used for chromatographic separation. The mobile phase was methanol-0.1% formic acid aqueous solution (65:35, v/v). The flow rate was 0.6 mL/min, while the column temperature and autosampler temperature were set as 35 ℃ and 8 ℃, respectively. The divert valve switching technique was used to protect the mass spectrometer. The six-way valve was set to divert the eluent of 7.5-11.6 min to waste and the rest of the eluent into the mass spectrometer. The Orbitrap mass spectrometer was coupled with the UHPLC system by an electrospray ion (ESI) source. The sheath gas and auxiliary gas flow rates were 60 and 20 arb (arbitrary units), respectively. The spray voltage was 3.5 kV, while the capillary temperature and auxiliary gas heater temperature were set as 350 ℃ and 400 ℃, respectively. The positive ion parallel reaction monitoring (PRM) scanning mode was adopted, and the mass spectral resolution was set to 35000 FWHM. The accurate masses of the [M+H](+) precursor ions of impurities 2, 6, and 12 were m/z 347.1230, 361.1026, and 347.1230, respectively. The accurate masses of the extracted [M+H](+) fragment ions of impurities 2, 6, and 12 were m/z 315.0968, 298.1069, and 315.0968, respectively. The normalized collision energies (NCEs) were optimized to 10%, 42%, and 10% for impurities 2, 6, and 12, respectively. The external standard method was utilized for quantitative analysis. The established method was validated in detail by investigating the specificity, linear range, limit of detection (LOD), limit of quantification (LOQ), recovery, precision, and stability. This method had good specificity, and the solvent did not interfere with the determination of impurities. The peak areas of impurities 2, 6, and 12 as well as their concentrations showed good linear relationships in the ranges of 0.2-100 ng/mL, with all correlation coefficients (r)≥0.9998. The recoveries of impurities 2, 6, and 12 at three levels (low, medium, and high) were in the range of 96.9%-105.0%, while the RSDs were between 1.21% and 5.12%. The LODs were 0.05 ng/mL and the LOQs were 0.2 ng/mL for all three impurities. This analytical method was used to determine impurities 2, 6, and 12 in three batches of nifedipine samples. Impurity 6 was not detected in the three batches, but impurities 2 and 12 were detected in all the three samples, and the detection amount was within the limit. The developed method is sensitive, fast, accurate, and easy to operate. It can provide a reference for the quality control of nifedipine by pharmaceutical companies and extend strong technical support for the supervision by drug regulatory authorities. Editorial board of Chinese Journal of Chromatography 2022-03-08 /pmc/articles/PMC9404017/ /pubmed/35243836 http://dx.doi.org/10.3724/SP.J.1123.2021.06008 Text en https://creativecommons.org/licenses/by/4.0/本文是开放获取文章,遵循CC BY 4.0协议 https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Articles
GUO, Changchuan
TAN, Huijie
LIU, Qi
GONG, Tengfei
WANG, Xue
WANG, Chenglin
XU, Yuwen
超高效液相色谱-静电场轨道阱高分辨质谱法测定硝苯地平中痕量基因毒性杂质
title 超高效液相色谱-静电场轨道阱高分辨质谱法测定硝苯地平中痕量基因毒性杂质
title_full 超高效液相色谱-静电场轨道阱高分辨质谱法测定硝苯地平中痕量基因毒性杂质
title_fullStr 超高效液相色谱-静电场轨道阱高分辨质谱法测定硝苯地平中痕量基因毒性杂质
title_full_unstemmed 超高效液相色谱-静电场轨道阱高分辨质谱法测定硝苯地平中痕量基因毒性杂质
title_short 超高效液相色谱-静电场轨道阱高分辨质谱法测定硝苯地平中痕量基因毒性杂质
title_sort 超高效液相色谱-静电场轨道阱高分辨质谱法测定硝苯地平中痕量基因毒性杂质
topic Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9404017/
https://www.ncbi.nlm.nih.gov/pubmed/35243836
http://dx.doi.org/10.3724/SP.J.1123.2021.06008
work_keys_str_mv AT guochangchuan chāogāoxiàoyèxiāngsèpǔjìngdiànchǎngguǐdàojǐnggāofēnbiànzhìpǔfǎcèdìngxiāoběndepíngzhōnghénliàngjīyīndúxìngzázhì
AT tanhuijie chāogāoxiàoyèxiāngsèpǔjìngdiànchǎngguǐdàojǐnggāofēnbiànzhìpǔfǎcèdìngxiāoběndepíngzhōnghénliàngjīyīndúxìngzázhì
AT liuqi chāogāoxiàoyèxiāngsèpǔjìngdiànchǎngguǐdàojǐnggāofēnbiànzhìpǔfǎcèdìngxiāoběndepíngzhōnghénliàngjīyīndúxìngzázhì
AT gongtengfei chāogāoxiàoyèxiāngsèpǔjìngdiànchǎngguǐdàojǐnggāofēnbiànzhìpǔfǎcèdìngxiāoběndepíngzhōnghénliàngjīyīndúxìngzázhì
AT wangxue chāogāoxiàoyèxiāngsèpǔjìngdiànchǎngguǐdàojǐnggāofēnbiànzhìpǔfǎcèdìngxiāoběndepíngzhōnghénliàngjīyīndúxìngzázhì
AT wangchenglin chāogāoxiàoyèxiāngsèpǔjìngdiànchǎngguǐdàojǐnggāofēnbiànzhìpǔfǎcèdìngxiāoběndepíngzhōnghénliàngjīyīndúxìngzázhì
AT xuyuwen chāogāoxiàoyèxiāngsèpǔjìngdiànchǎngguǐdàojǐnggāofēnbiànzhìpǔfǎcèdìngxiāoběndepíngzhōnghénliàngjīyīndúxìngzázhì