Cargando…

高效液相色谱法测定氧化型染发产品中40种染发剂

Oxidative hair dye products have always been one of the key concerns in cosmetic supervision. The various aromatic amine and phenol dyes used in such products have different degrees of sensitization and toxicities. Therefore, it is necessary to establish a rapid and accurate method for the determina...

Descripción completa

Detalles Bibliográficos
Autores principales: ZUO, Xue, DI, Zheng, DU, Yong, YANG, Ling, ZHANG, Rong, WU, Guoqing
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Editorial board of Chinese Journal of Chromatography 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9404089/
https://www.ncbi.nlm.nih.gov/pubmed/34677017
http://dx.doi.org/10.3724/SP.J.1123.2020.11020
_version_ 1784773542955450368
author ZUO, Xue
DI, Zheng
DU, Yong
YANG, Ling
ZHANG, Rong
WU, Guoqing
author_facet ZUO, Xue
DI, Zheng
DU, Yong
YANG, Ling
ZHANG, Rong
WU, Guoqing
author_sort ZUO, Xue
collection PubMed
description Oxidative hair dye products have always been one of the key concerns in cosmetic supervision. The various aromatic amine and phenol dyes used in such products have different degrees of sensitization and toxicities. Therefore, it is necessary to establish a rapid and accurate method for the determination of various dyes. A high performance liquid chromatography (HPLC) method was developed for the determination of 40 dyes in oxidative hair dye products, and the method was optimized in terms of mobile phase type, column temperature, detection wavelength, and extraction solvent concentration. The sample pretreatment method was as follows: weighed 0.5 g sample accurately, added to 10 mL of sodium bisulfite solution containing 70% ethanol, extracted by ultrasonication for 15 min, added to 25 mL of the sodium bisulfite solution. Chromatographic separation was carried out on a Waters Atlantis(®) T3 MV Kit column (250 mm×4.6 mm, 5 μm) by gradient elution. To protect the column, the sample solution was filtered using a syringe filter with a 0.45-μm membrane before injection. The mobile phase was 0.02 mol/L ammonium acetate aqueous solution (containing 4% acetonitrile) and acetonitrile. The column temperature was varied between 30 ℃ and 35 ℃ during the separation. The dyes were detected using a photodiode array detector. The detection wavelength of 31 dyes was 235 nm, and that of the other nine dyes was 280 nm. The external standard method was used for quantitative analysis. The results showed that the 40 dyes could be separated well. All the dyes had good linearities in their own concentration ranges, with correlation coefficients (r) exceeding 0.999. The limits of detection (LODs) of the 40 dyes ranged from 5 to 168 μg/g, and the limits of quantification (LOQs) ranged from 16 to 504 μg/g. The average spiked recoveries at three levels (2.5, 5.0, and 10 mg/g) of the 40 dyes ranged from 81.4% to 109.6%, with relative standard deviations (RSDs) less than 5%. The stability of each dye in the standard solutions was good within 24 h, with RSDs ranging from 0.2% to 2.2%. To demonstrate the applicability of the method, 12 batches of commercial oxidative hair dye products from different manufacturers were analyzed. In total, 24 kinds of dyes were detected in the 12 batches of samples, and the contents of these dyes ranged from 0.01% to 2.83%. The method greatly increased the types of dyes detected by a single chromatography step, especially the permitted dyes (36 types). Compared with the standard method of Safety and Technical Standards for Cosmetics (2015 edition), this method replenished 13 permitted dyes: 1-hydroxyethyl 4,5-diaminopyrazole sulfate, hydroxyethyl-p-phenylenediaminesulfate, tetraaminopyrimidine sulfate, 2,6-dihydroxyethylaminotoluene, 2-amino-6-chloro-4-nitrophenol, 2-methyl-5-hydroxyethylaminophenol, 3-nitro-p-hydroxyethylaminophenol, 4-hydroxypropylamino-3-nitrophenol, 5-amino-4-chloro-o-cresol, 5-amino-6-chloro-o-cresol, HC yellow No. 2, hydroxybenzomorpholine, and hydroxyethyl-2-nitro-p-toluidine. The sensitivity and accuracy of the results could ensure and the detection efficiency could be improved through validation of the method. The developed method is suitable for the determination of various dyes in oxidative hair dye products and can provide an effective technical means for the supervision of such products.
format Online
Article
Text
id pubmed-9404089
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Editorial board of Chinese Journal of Chromatography
record_format MEDLINE/PubMed
spelling pubmed-94040892022-09-14 高效液相色谱法测定氧化型染发产品中40种染发剂 ZUO, Xue DI, Zheng DU, Yong YANG, Ling ZHANG, Rong WU, Guoqing Se Pu Articles Oxidative hair dye products have always been one of the key concerns in cosmetic supervision. The various aromatic amine and phenol dyes used in such products have different degrees of sensitization and toxicities. Therefore, it is necessary to establish a rapid and accurate method for the determination of various dyes. A high performance liquid chromatography (HPLC) method was developed for the determination of 40 dyes in oxidative hair dye products, and the method was optimized in terms of mobile phase type, column temperature, detection wavelength, and extraction solvent concentration. The sample pretreatment method was as follows: weighed 0.5 g sample accurately, added to 10 mL of sodium bisulfite solution containing 70% ethanol, extracted by ultrasonication for 15 min, added to 25 mL of the sodium bisulfite solution. Chromatographic separation was carried out on a Waters Atlantis(®) T3 MV Kit column (250 mm×4.6 mm, 5 μm) by gradient elution. To protect the column, the sample solution was filtered using a syringe filter with a 0.45-μm membrane before injection. The mobile phase was 0.02 mol/L ammonium acetate aqueous solution (containing 4% acetonitrile) and acetonitrile. The column temperature was varied between 30 ℃ and 35 ℃ during the separation. The dyes were detected using a photodiode array detector. The detection wavelength of 31 dyes was 235 nm, and that of the other nine dyes was 280 nm. The external standard method was used for quantitative analysis. The results showed that the 40 dyes could be separated well. All the dyes had good linearities in their own concentration ranges, with correlation coefficients (r) exceeding 0.999. The limits of detection (LODs) of the 40 dyes ranged from 5 to 168 μg/g, and the limits of quantification (LOQs) ranged from 16 to 504 μg/g. The average spiked recoveries at three levels (2.5, 5.0, and 10 mg/g) of the 40 dyes ranged from 81.4% to 109.6%, with relative standard deviations (RSDs) less than 5%. The stability of each dye in the standard solutions was good within 24 h, with RSDs ranging from 0.2% to 2.2%. To demonstrate the applicability of the method, 12 batches of commercial oxidative hair dye products from different manufacturers were analyzed. In total, 24 kinds of dyes were detected in the 12 batches of samples, and the contents of these dyes ranged from 0.01% to 2.83%. The method greatly increased the types of dyes detected by a single chromatography step, especially the permitted dyes (36 types). Compared with the standard method of Safety and Technical Standards for Cosmetics (2015 edition), this method replenished 13 permitted dyes: 1-hydroxyethyl 4,5-diaminopyrazole sulfate, hydroxyethyl-p-phenylenediaminesulfate, tetraaminopyrimidine sulfate, 2,6-dihydroxyethylaminotoluene, 2-amino-6-chloro-4-nitrophenol, 2-methyl-5-hydroxyethylaminophenol, 3-nitro-p-hydroxyethylaminophenol, 4-hydroxypropylamino-3-nitrophenol, 5-amino-4-chloro-o-cresol, 5-amino-6-chloro-o-cresol, HC yellow No. 2, hydroxybenzomorpholine, and hydroxyethyl-2-nitro-p-toluidine. The sensitivity and accuracy of the results could ensure and the detection efficiency could be improved through validation of the method. The developed method is suitable for the determination of various dyes in oxidative hair dye products and can provide an effective technical means for the supervision of such products. Editorial board of Chinese Journal of Chromatography 2021-11-08 /pmc/articles/PMC9404089/ /pubmed/34677017 http://dx.doi.org/10.3724/SP.J.1123.2020.11020 Text en https://creativecommons.org/licenses/by/4.0/本文是开放获取文章,遵循CC BY 4.0协议 https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Articles
ZUO, Xue
DI, Zheng
DU, Yong
YANG, Ling
ZHANG, Rong
WU, Guoqing
高效液相色谱法测定氧化型染发产品中40种染发剂
title 高效液相色谱法测定氧化型染发产品中40种染发剂
title_full 高效液相色谱法测定氧化型染发产品中40种染发剂
title_fullStr 高效液相色谱法测定氧化型染发产品中40种染发剂
title_full_unstemmed 高效液相色谱法测定氧化型染发产品中40种染发剂
title_short 高效液相色谱法测定氧化型染发产品中40种染发剂
title_sort 高效液相色谱法测定氧化型染发产品中40种染发剂
topic Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9404089/
https://www.ncbi.nlm.nih.gov/pubmed/34677017
http://dx.doi.org/10.3724/SP.J.1123.2020.11020
work_keys_str_mv AT zuoxue gāoxiàoyèxiāngsèpǔfǎcèdìngyǎnghuàxíngrǎnfāchǎnpǐnzhōng40zhǒngrǎnfājì
AT dizheng gāoxiàoyèxiāngsèpǔfǎcèdìngyǎnghuàxíngrǎnfāchǎnpǐnzhōng40zhǒngrǎnfājì
AT duyong gāoxiàoyèxiāngsèpǔfǎcèdìngyǎnghuàxíngrǎnfāchǎnpǐnzhōng40zhǒngrǎnfājì
AT yangling gāoxiàoyèxiāngsèpǔfǎcèdìngyǎnghuàxíngrǎnfāchǎnpǐnzhōng40zhǒngrǎnfājì
AT zhangrong gāoxiàoyèxiāngsèpǔfǎcèdìngyǎnghuàxíngrǎnfāchǎnpǐnzhōng40zhǒngrǎnfājì
AT wuguoqing gāoxiàoyèxiāngsèpǔfǎcèdìngyǎnghuàxíngrǎnfāchǎnpǐnzhōng40zhǒngrǎnfājì