Cargando…
QuEChERS-同位素内标-高效液相色谱-串联质谱法测定动物源性食品中植物生长调节剂类农药残留
As among the most widely used pesticides in agriculture, plant growth regulators (PGRs) have a positive influence on plants. However, the overuse of PGRs may induce toxicity in food and even be hazardous to human health. Numerous studies have investigated the presence and residues of PGRs on vegetab...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Editorial board of Chinese Journal of Chromatography
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9404141/ https://www.ncbi.nlm.nih.gov/pubmed/34677016 http://dx.doi.org/10.3724/SP.J.1123.2021.01029 |
_version_ | 1784773562886782976 |
---|---|
author | DAI, Wei LI, Qiao ZHU, Ming LIANG, Yixin CAI, Qiu WANG, Mian LI, Jie LIU, Kangshu WANG, Xingning |
author_facet | DAI, Wei LI, Qiao ZHU, Ming LIANG, Yixin CAI, Qiu WANG, Mian LI, Jie LIU, Kangshu WANG, Xingning |
author_sort | DAI, Wei |
collection | PubMed |
description | As among the most widely used pesticides in agriculture, plant growth regulators (PGRs) have a positive influence on plants. However, the overuse of PGRs may induce toxicity in food and even be hazardous to human health. Numerous studies have investigated the presence and residues of PGRs on vegetables and fruits. Animal-derived foods are one of the most dominant food sources providing nutrients to fulfil the daily dietary intake, and could also be potentially contaminated by PGRs. However, there is little information on PGR residues in animal-derived foods. Standardization also lacks among the techniques for PGR determination in animal-derived foods, thereby restricting the further establishment of pesticide usage and food safety regulations. Therefore, in this study, a rapid and effective method for analyzing chlormequat chloride, thidiazuron, and paclobutrazol in animal-derived food samples was established. The method primarily involves high performance liquid chromatography-tandem mass spectrometry combined with the use of isotope-labeled internal standards. The extraction and clean-up procedures were based on the QuEChERS method. The analytes were extracted from pork, beef, chicken, pork liver, egg, and milk samples using acetonitrile, followed by 4 g anhydrous magnesium sulfate (MgSO(4)), and 1 g sodium chloride (NaCl). The supernatant was removed using a mixture of 50 mg N-propyl ethylenediamine (PSA), 50 mg octadecyl silane (C18), and 150 mg MgSO(4), and then passed through a 0.22 μm membrane filter before determination. The Agilent ZORBAX Eclipse Plus C18 column (150 mm×3.0 mm, 1.8 μm) was used to separate the analytes under a gradient elution program, with acetonitrile and 5 mmol/L ammonium acetate solution as mobile phases. The analytes were detected by mass spectrometry using the positive and negative electrospray ionization modes under the multiple reaction monitoring mode. Matrix-matched calibration combined with internal standards was used to quantify the PGRs. The linear regression correlation coefficients (r(2)) for the PGRs were all greater than 0.990 in the corresponding linear concentration ranges. Chlormequat chloride, thidiazuron, and paclobutrazol showed good linearities in the range of 0.1-100 μg/L for the egg and pork liver samples and 0.1-50 μg/L for the pork, beef, and chicken samples. For the milk samples, thidiazuron and paclobutrazol showed good linearities in the range of 0.05-10 μg/L, while chlormequat chloride showed linearity in the range of 0.05-5 μg/L. The limit of detection (LOD) and limit of quantification (LOQ) for each PGR were based on the signal-to-noise (S/N) ratios. Under optimal conditions, the LODs ranged from 0.01 μg/kg to 0.1 μg/kg, where the LOD was defined as the amount of the tested compound that generated an S/N ratio higher than 3. In addition, the LOQs were in the range of 0.5-5 μg/kg, with an S/N ratio higher than 10. The precision and accuracy were evaluated by recovery experiments. At the LOQ, twice the LOQ, and 10 times the LOQ, the mean recoveries were in the range of 70.0%-117.4%, and the relative standard deviations (RSDs) ranged from 0.8% to 16.1%. The results indicated that the proposed method is accurate and reliable. This method is a modification of the QuEChERS method, and is advantageous owing to its simplicity and high sensitivity. The use of matrix-matching calibration curves and internal standards can eliminate matrix interference, thereby increasing the accuracy of the method. This method satisfies the testing requirements for chlormequat chloride, thidiazuron, and paclobutrazol residues in animal-derived foods, and is promising for the determination of other PGRs or other types of pesticides in animal-derived foods. |
format | Online Article Text |
id | pubmed-9404141 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Editorial board of Chinese Journal of Chromatography |
record_format | MEDLINE/PubMed |
spelling | pubmed-94041412022-09-14 QuEChERS-同位素内标-高效液相色谱-串联质谱法测定动物源性食品中植物生长调节剂类农药残留 DAI, Wei LI, Qiao ZHU, Ming LIANG, Yixin CAI, Qiu WANG, Mian LI, Jie LIU, Kangshu WANG, Xingning Se Pu Articles As among the most widely used pesticides in agriculture, plant growth regulators (PGRs) have a positive influence on plants. However, the overuse of PGRs may induce toxicity in food and even be hazardous to human health. Numerous studies have investigated the presence and residues of PGRs on vegetables and fruits. Animal-derived foods are one of the most dominant food sources providing nutrients to fulfil the daily dietary intake, and could also be potentially contaminated by PGRs. However, there is little information on PGR residues in animal-derived foods. Standardization also lacks among the techniques for PGR determination in animal-derived foods, thereby restricting the further establishment of pesticide usage and food safety regulations. Therefore, in this study, a rapid and effective method for analyzing chlormequat chloride, thidiazuron, and paclobutrazol in animal-derived food samples was established. The method primarily involves high performance liquid chromatography-tandem mass spectrometry combined with the use of isotope-labeled internal standards. The extraction and clean-up procedures were based on the QuEChERS method. The analytes were extracted from pork, beef, chicken, pork liver, egg, and milk samples using acetonitrile, followed by 4 g anhydrous magnesium sulfate (MgSO(4)), and 1 g sodium chloride (NaCl). The supernatant was removed using a mixture of 50 mg N-propyl ethylenediamine (PSA), 50 mg octadecyl silane (C18), and 150 mg MgSO(4), and then passed through a 0.22 μm membrane filter before determination. The Agilent ZORBAX Eclipse Plus C18 column (150 mm×3.0 mm, 1.8 μm) was used to separate the analytes under a gradient elution program, with acetonitrile and 5 mmol/L ammonium acetate solution as mobile phases. The analytes were detected by mass spectrometry using the positive and negative electrospray ionization modes under the multiple reaction monitoring mode. Matrix-matched calibration combined with internal standards was used to quantify the PGRs. The linear regression correlation coefficients (r(2)) for the PGRs were all greater than 0.990 in the corresponding linear concentration ranges. Chlormequat chloride, thidiazuron, and paclobutrazol showed good linearities in the range of 0.1-100 μg/L for the egg and pork liver samples and 0.1-50 μg/L for the pork, beef, and chicken samples. For the milk samples, thidiazuron and paclobutrazol showed good linearities in the range of 0.05-10 μg/L, while chlormequat chloride showed linearity in the range of 0.05-5 μg/L. The limit of detection (LOD) and limit of quantification (LOQ) for each PGR were based on the signal-to-noise (S/N) ratios. Under optimal conditions, the LODs ranged from 0.01 μg/kg to 0.1 μg/kg, where the LOD was defined as the amount of the tested compound that generated an S/N ratio higher than 3. In addition, the LOQs were in the range of 0.5-5 μg/kg, with an S/N ratio higher than 10. The precision and accuracy were evaluated by recovery experiments. At the LOQ, twice the LOQ, and 10 times the LOQ, the mean recoveries were in the range of 70.0%-117.4%, and the relative standard deviations (RSDs) ranged from 0.8% to 16.1%. The results indicated that the proposed method is accurate and reliable. This method is a modification of the QuEChERS method, and is advantageous owing to its simplicity and high sensitivity. The use of matrix-matching calibration curves and internal standards can eliminate matrix interference, thereby increasing the accuracy of the method. This method satisfies the testing requirements for chlormequat chloride, thidiazuron, and paclobutrazol residues in animal-derived foods, and is promising for the determination of other PGRs or other types of pesticides in animal-derived foods. Editorial board of Chinese Journal of Chromatography 2021-11-08 /pmc/articles/PMC9404141/ /pubmed/34677016 http://dx.doi.org/10.3724/SP.J.1123.2021.01029 Text en https://creativecommons.org/licenses/by/4.0/本文是开放获取文章,遵循CC BY 4.0协议 https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Articles DAI, Wei LI, Qiao ZHU, Ming LIANG, Yixin CAI, Qiu WANG, Mian LI, Jie LIU, Kangshu WANG, Xingning QuEChERS-同位素内标-高效液相色谱-串联质谱法测定动物源性食品中植物生长调节剂类农药残留 |
title | QuEChERS-同位素内标-高效液相色谱-串联质谱法测定动物源性食品中植物生长调节剂类农药残留 |
title_full | QuEChERS-同位素内标-高效液相色谱-串联质谱法测定动物源性食品中植物生长调节剂类农药残留 |
title_fullStr | QuEChERS-同位素内标-高效液相色谱-串联质谱法测定动物源性食品中植物生长调节剂类农药残留 |
title_full_unstemmed | QuEChERS-同位素内标-高效液相色谱-串联质谱法测定动物源性食品中植物生长调节剂类农药残留 |
title_short | QuEChERS-同位素内标-高效液相色谱-串联质谱法测定动物源性食品中植物生长调节剂类农药残留 |
title_sort | quechers-同位素内标-高效液相色谱-串联质谱法测定动物源性食品中植物生长调节剂类农药残留 |
topic | Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9404141/ https://www.ncbi.nlm.nih.gov/pubmed/34677016 http://dx.doi.org/10.3724/SP.J.1123.2021.01029 |
work_keys_str_mv | AT daiwei quecherstóngwèisùnèibiāogāoxiàoyèxiāngsèpǔchuànliánzhìpǔfǎcèdìngdòngwùyuánxìngshípǐnzhōngzhíwùshēngzhǎngdiàojiéjìlèinóngyàocánliú AT liqiao quecherstóngwèisùnèibiāogāoxiàoyèxiāngsèpǔchuànliánzhìpǔfǎcèdìngdòngwùyuánxìngshípǐnzhōngzhíwùshēngzhǎngdiàojiéjìlèinóngyàocánliú AT zhuming quecherstóngwèisùnèibiāogāoxiàoyèxiāngsèpǔchuànliánzhìpǔfǎcèdìngdòngwùyuánxìngshípǐnzhōngzhíwùshēngzhǎngdiàojiéjìlèinóngyàocánliú AT liangyixin quecherstóngwèisùnèibiāogāoxiàoyèxiāngsèpǔchuànliánzhìpǔfǎcèdìngdòngwùyuánxìngshípǐnzhōngzhíwùshēngzhǎngdiàojiéjìlèinóngyàocánliú AT caiqiu quecherstóngwèisùnèibiāogāoxiàoyèxiāngsèpǔchuànliánzhìpǔfǎcèdìngdòngwùyuánxìngshípǐnzhōngzhíwùshēngzhǎngdiàojiéjìlèinóngyàocánliú AT wangmian quecherstóngwèisùnèibiāogāoxiàoyèxiāngsèpǔchuànliánzhìpǔfǎcèdìngdòngwùyuánxìngshípǐnzhōngzhíwùshēngzhǎngdiàojiéjìlèinóngyàocánliú AT lijie quecherstóngwèisùnèibiāogāoxiàoyèxiāngsèpǔchuànliánzhìpǔfǎcèdìngdòngwùyuánxìngshípǐnzhōngzhíwùshēngzhǎngdiàojiéjìlèinóngyàocánliú AT liukangshu quecherstóngwèisùnèibiāogāoxiàoyèxiāngsèpǔchuànliánzhìpǔfǎcèdìngdòngwùyuánxìngshípǐnzhōngzhíwùshēngzhǎngdiàojiéjìlèinóngyàocánliú AT wangxingning quecherstóngwèisùnèibiāogāoxiàoyèxiāngsèpǔchuànliánzhìpǔfǎcèdìngdòngwùyuánxìngshípǐnzhōngzhíwùshēngzhǎngdiàojiéjìlèinóngyàocánliú |