Cargando…

大体积直接进样-超高效液相色谱-三重四极杆质谱法测定水中7大类42种抗生素残留

Antibiotics are emerging contaminants that have recently attracted attention. They have been detected in natural water and pose health concerns owing to potential antibiotic resistance. Antibiotics are ubiquitous in aquatic environments, with a wide spectrum and trace levels. It is difficult to dete...

Descripción completa

Detalles Bibliográficos
Autores principales: SUN, Huijing, LI, Peiwen, ZHANG, Beibei, CHEN, Huiming
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Editorial board of Chinese Journal of Chromatography 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9404143/
https://www.ncbi.nlm.nih.gov/pubmed/35362681
http://dx.doi.org/10.3724/SP.J.1123.2021.08010
_version_ 1784773563655389184
author SUN, Huijing
LI, Peiwen
ZHANG, Beibei
CHEN, Huiming
author_facet SUN, Huijing
LI, Peiwen
ZHANG, Beibei
CHEN, Huiming
author_sort SUN, Huijing
collection PubMed
description Antibiotics are emerging contaminants that have recently attracted attention. They have been detected in natural water and pose health concerns owing to potential antibiotic resistance. Antibiotics are ubiquitous in aquatic environments, with a wide spectrum and trace levels. It is difficult to detect all types of antibiotics with completely different physicochemical properties. Solid phase extraction (SPE) is a common sample preparation procedure. For a fast and high-throughput continuous on-line analysis of these emerging contaminants, a method for the determination of 42 antibiotics (grouped into seven categories: sulfonamides, fluoroquinolones, lincosamides, macrolides, tetracyclines, cephalosporins, and chloramphenicols) in environmental water was developed based on ultra high performance liquid chromatography combined with tandem mass spectrometry (UHPLC-MS/MS) involving large volume direct injection without sample enrichment and cleanup. The collected water samples were filtered through a 0.22-μm filter membrane, their pH levels were adjusted to 6.0-8.0 after adding Na(2)EDTA, and then the solutions were mixed with an internal standard. The addition of Na(2)EDTA contributed to the release of tetracyclines and fluoroquinolones from the metal chelate. Improved recoveries were observed for all the compounds when the pH of the aqueous solution was set at 6.0-8.0. The optimized UHPLC conditions were as follows: chromatographic column, Phenomenex Kinetex C18 column (50 mm×30 mm, 2.6 μm); mobile phase, acetonitrile and 0.1% (v/v) formic acid aqueous solution; flow rate, 0.4 mL/min; injection volume, 100 μL. In the UHPLC-MS/MS experiment, chloramphenicol, thiamphenicol, and florfenicol were analyzed in the negative ionization scheduled multiple reaction monitoring mode (scheduled-MRM), while the other 39 antibiotics were analyzed in the positive scheduled-MRM mode. This acquisition method improved the response of each target compound by dividing the time of the analysis test cycle and scanning the ion channels of chromatographic peaks at different time periods. The ionspray voltage was set at 5500 and -4500 V in positive and negative modes, respectively. The source temperature for both ionization modes was set at 500 ℃, which was optimized to improve the sensitivity. Instrumental parameters like collision energy and declustering potential were also optimized. Good linearity was observed for all the tested antibiotics, with a correlation coefficient (r) greater than 0.995. The method detection limits (MDLs) were 0.015-3.561 ng/L. The average recoveries ranged from 80.1% to 125%, while the relative standard deviations (RSDs) were between 0.8% and 12.2%. The method was successfully applied to the determination of 10 source water samples and 5 tap water samples. Twelve antibiotics, viz. sulfachloropyridazine, sulfadiazine, sulfamethazine, sulfamethoxazole, sulfisomidine, clindamycin, lincomycin, roxithromycin, clarithromycin, erythromycin, thiamphenicol, and forfenicol, were detected in the 10 water samples with a detection frequency of 100%. The total antibiotic content in each sample ranged from not detected to 80.3 ng/L. Lincosamides and chloramphenicols were the predominant antibiotics in the water samples, with contents in the ranges of 3.83-13.7 and 4.23-33.6 ng/L, respectively. Therefore, the large volume direct injection method exhibited good performance in terms of MDL and recovery compared to standard methods and those reported previously. Compared with traditional pretreatment methods, the large volume direct injection method is simpler, more rapid, more precise, and more accurate. It is a viable alternative to SPE, and can be used for the determination of the 42 antibiotics at trace levels in cleaner water bodies, such as surface water, groundwater, and tap water.
format Online
Article
Text
id pubmed-9404143
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Editorial board of Chinese Journal of Chromatography
record_format MEDLINE/PubMed
spelling pubmed-94041432022-09-14 大体积直接进样-超高效液相色谱-三重四极杆质谱法测定水中7大类42种抗生素残留 SUN, Huijing LI, Peiwen ZHANG, Beibei CHEN, Huiming Se Pu Articles Antibiotics are emerging contaminants that have recently attracted attention. They have been detected in natural water and pose health concerns owing to potential antibiotic resistance. Antibiotics are ubiquitous in aquatic environments, with a wide spectrum and trace levels. It is difficult to detect all types of antibiotics with completely different physicochemical properties. Solid phase extraction (SPE) is a common sample preparation procedure. For a fast and high-throughput continuous on-line analysis of these emerging contaminants, a method for the determination of 42 antibiotics (grouped into seven categories: sulfonamides, fluoroquinolones, lincosamides, macrolides, tetracyclines, cephalosporins, and chloramphenicols) in environmental water was developed based on ultra high performance liquid chromatography combined with tandem mass spectrometry (UHPLC-MS/MS) involving large volume direct injection without sample enrichment and cleanup. The collected water samples were filtered through a 0.22-μm filter membrane, their pH levels were adjusted to 6.0-8.0 after adding Na(2)EDTA, and then the solutions were mixed with an internal standard. The addition of Na(2)EDTA contributed to the release of tetracyclines and fluoroquinolones from the metal chelate. Improved recoveries were observed for all the compounds when the pH of the aqueous solution was set at 6.0-8.0. The optimized UHPLC conditions were as follows: chromatographic column, Phenomenex Kinetex C18 column (50 mm×30 mm, 2.6 μm); mobile phase, acetonitrile and 0.1% (v/v) formic acid aqueous solution; flow rate, 0.4 mL/min; injection volume, 100 μL. In the UHPLC-MS/MS experiment, chloramphenicol, thiamphenicol, and florfenicol were analyzed in the negative ionization scheduled multiple reaction monitoring mode (scheduled-MRM), while the other 39 antibiotics were analyzed in the positive scheduled-MRM mode. This acquisition method improved the response of each target compound by dividing the time of the analysis test cycle and scanning the ion channels of chromatographic peaks at different time periods. The ionspray voltage was set at 5500 and -4500 V in positive and negative modes, respectively. The source temperature for both ionization modes was set at 500 ℃, which was optimized to improve the sensitivity. Instrumental parameters like collision energy and declustering potential were also optimized. Good linearity was observed for all the tested antibiotics, with a correlation coefficient (r) greater than 0.995. The method detection limits (MDLs) were 0.015-3.561 ng/L. The average recoveries ranged from 80.1% to 125%, while the relative standard deviations (RSDs) were between 0.8% and 12.2%. The method was successfully applied to the determination of 10 source water samples and 5 tap water samples. Twelve antibiotics, viz. sulfachloropyridazine, sulfadiazine, sulfamethazine, sulfamethoxazole, sulfisomidine, clindamycin, lincomycin, roxithromycin, clarithromycin, erythromycin, thiamphenicol, and forfenicol, were detected in the 10 water samples with a detection frequency of 100%. The total antibiotic content in each sample ranged from not detected to 80.3 ng/L. Lincosamides and chloramphenicols were the predominant antibiotics in the water samples, with contents in the ranges of 3.83-13.7 and 4.23-33.6 ng/L, respectively. Therefore, the large volume direct injection method exhibited good performance in terms of MDL and recovery compared to standard methods and those reported previously. Compared with traditional pretreatment methods, the large volume direct injection method is simpler, more rapid, more precise, and more accurate. It is a viable alternative to SPE, and can be used for the determination of the 42 antibiotics at trace levels in cleaner water bodies, such as surface water, groundwater, and tap water. Editorial board of Chinese Journal of Chromatography 2022-04-08 /pmc/articles/PMC9404143/ /pubmed/35362681 http://dx.doi.org/10.3724/SP.J.1123.2021.08010 Text en https://creativecommons.org/licenses/by/4.0/本文是开放获取文章,遵循CC BY 4.0协议 https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Articles
SUN, Huijing
LI, Peiwen
ZHANG, Beibei
CHEN, Huiming
大体积直接进样-超高效液相色谱-三重四极杆质谱法测定水中7大类42种抗生素残留
title 大体积直接进样-超高效液相色谱-三重四极杆质谱法测定水中7大类42种抗生素残留
title_full 大体积直接进样-超高效液相色谱-三重四极杆质谱法测定水中7大类42种抗生素残留
title_fullStr 大体积直接进样-超高效液相色谱-三重四极杆质谱法测定水中7大类42种抗生素残留
title_full_unstemmed 大体积直接进样-超高效液相色谱-三重四极杆质谱法测定水中7大类42种抗生素残留
title_short 大体积直接进样-超高效液相色谱-三重四极杆质谱法测定水中7大类42种抗生素残留
title_sort 大体积直接进样-超高效液相色谱-三重四极杆质谱法测定水中7大类42种抗生素残留
topic Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9404143/
https://www.ncbi.nlm.nih.gov/pubmed/35362681
http://dx.doi.org/10.3724/SP.J.1123.2021.08010
work_keys_str_mv AT sunhuijing dàtǐjīzhíjiējìnyàngchāogāoxiàoyèxiāngsèpǔsānzhòngsìjígānzhìpǔfǎcèdìngshuǐzhōng7dàlèi42zhǒngkàngshēngsùcánliú
AT lipeiwen dàtǐjīzhíjiējìnyàngchāogāoxiàoyèxiāngsèpǔsānzhòngsìjígānzhìpǔfǎcèdìngshuǐzhōng7dàlèi42zhǒngkàngshēngsùcánliú
AT zhangbeibei dàtǐjīzhíjiējìnyàngchāogāoxiàoyèxiāngsèpǔsānzhòngsìjígānzhìpǔfǎcèdìngshuǐzhōng7dàlèi42zhǒngkàngshēngsùcánliú
AT chenhuiming dàtǐjīzhíjiējìnyàngchāogāoxiàoyèxiāngsèpǔsānzhòngsìjígānzhìpǔfǎcèdìngshuǐzhōng7dàlèi42zhǒngkàngshēngsùcánliú