Mesowestern Blot: Simultaneous Analysis of Hundreds of Submicroliter Lysates

[Image: see text] Western blotting is a widely used technique for molecular-weight-resolved analysis of proteins and their posttranslational modifications, but high-throughput implementations of the standard slab gel arrangement are scarce. The previously developed Microwestern requires a piezoelect...

Descripción completa

Detalles Bibliográficos
Autores principales: Zadeh, Cameron O., Huggins, Jonah R., Sarmah, Deepraj, Westbury, Baylee C., Interiano, William R., Jordan, Micah C., Phillips, S. Ashley, Dodd, William B., Meredith, Wesley O., Harold, Nicholas J., Erdem, Cemal, Birtwistle, Marc R.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Chemical Society 2022
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9404195/
https://www.ncbi.nlm.nih.gov/pubmed/36033686
http://dx.doi.org/10.1021/acsomega.2c02201
_version_ 1784773580415827968
author Zadeh, Cameron O.
Huggins, Jonah R.
Sarmah, Deepraj
Westbury, Baylee C.
Interiano, William R.
Jordan, Micah C.
Phillips, S. Ashley
Dodd, William B.
Meredith, Wesley O.
Harold, Nicholas J.
Erdem, Cemal
Birtwistle, Marc R.
author_facet Zadeh, Cameron O.
Huggins, Jonah R.
Sarmah, Deepraj
Westbury, Baylee C.
Interiano, William R.
Jordan, Micah C.
Phillips, S. Ashley
Dodd, William B.
Meredith, Wesley O.
Harold, Nicholas J.
Erdem, Cemal
Birtwistle, Marc R.
author_sort Zadeh, Cameron O.
collection PubMed
description [Image: see text] Western blotting is a widely used technique for molecular-weight-resolved analysis of proteins and their posttranslational modifications, but high-throughput implementations of the standard slab gel arrangement are scarce. The previously developed Microwestern requires a piezoelectric pipetting instrument, which is not available for many labs. Here, we report the Mesowestern blot, which uses a 3D-printable gel casting mold to enable high-throughput Western blotting without piezoelectric pipetting and is compatible with the standard sample preparation and small (∼1 μL) sample sizes. The main tradeoffs are reduced molecular weight resolution and higher sample-to-sample CV, making it suitable for qualitative screening applications. The casted polyacrylamide gel contains 336, ∼0.5 μL micropipette-loadable sample wells arranged within a standard microplate footprint. Polyacrylamide % can be altered to change molecular weight resolution profiles. Proof-of-concept experiments using both infrared-fluorescent molecular weight protein ladder and cell lysate (RIPA buffer) demonstrate that the protein loaded in Mesowestern gels is amenable to the standard Western blotting steps. The main difference between Mesowestern and traditional Western is that semidry horizontal instead of immersed vertical gel electrophoresis is used. The linear range of detection is at least 32-fold, and at least ∼500 attomols of β-actin can be detected (∼29 ng of total protein from mammalian cell lysates: ∼100–300 cells). Because the gel mold is 3D-printable, users with access to additive manufacturing cores have significant design freedom for custom layouts. We expect that the technique could be easily adopted by any typical cell and molecular biology laboratory already performing Western blots.
format Online
Article
Text
id pubmed-9404195
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher American Chemical Society
record_format MEDLINE/PubMed
spelling pubmed-94041952022-08-26 Mesowestern Blot: Simultaneous Analysis of Hundreds of Submicroliter Lysates Zadeh, Cameron O. Huggins, Jonah R. Sarmah, Deepraj Westbury, Baylee C. Interiano, William R. Jordan, Micah C. Phillips, S. Ashley Dodd, William B. Meredith, Wesley O. Harold, Nicholas J. Erdem, Cemal Birtwistle, Marc R. ACS Omega [Image: see text] Western blotting is a widely used technique for molecular-weight-resolved analysis of proteins and their posttranslational modifications, but high-throughput implementations of the standard slab gel arrangement are scarce. The previously developed Microwestern requires a piezoelectric pipetting instrument, which is not available for many labs. Here, we report the Mesowestern blot, which uses a 3D-printable gel casting mold to enable high-throughput Western blotting without piezoelectric pipetting and is compatible with the standard sample preparation and small (∼1 μL) sample sizes. The main tradeoffs are reduced molecular weight resolution and higher sample-to-sample CV, making it suitable for qualitative screening applications. The casted polyacrylamide gel contains 336, ∼0.5 μL micropipette-loadable sample wells arranged within a standard microplate footprint. Polyacrylamide % can be altered to change molecular weight resolution profiles. Proof-of-concept experiments using both infrared-fluorescent molecular weight protein ladder and cell lysate (RIPA buffer) demonstrate that the protein loaded in Mesowestern gels is amenable to the standard Western blotting steps. The main difference between Mesowestern and traditional Western is that semidry horizontal instead of immersed vertical gel electrophoresis is used. The linear range of detection is at least 32-fold, and at least ∼500 attomols of β-actin can be detected (∼29 ng of total protein from mammalian cell lysates: ∼100–300 cells). Because the gel mold is 3D-printable, users with access to additive manufacturing cores have significant design freedom for custom layouts. We expect that the technique could be easily adopted by any typical cell and molecular biology laboratory already performing Western blots. American Chemical Society 2022-08-11 /pmc/articles/PMC9404195/ /pubmed/36033686 http://dx.doi.org/10.1021/acsomega.2c02201 Text en © 2022 The Authors. Published by American Chemical Society https://creativecommons.org/licenses/by-nc-nd/4.0/Permits non-commercial access and re-use, provided that author attribution and integrity are maintained; but does not permit creation of adaptations or other derivative works (https://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Zadeh, Cameron O.
Huggins, Jonah R.
Sarmah, Deepraj
Westbury, Baylee C.
Interiano, William R.
Jordan, Micah C.
Phillips, S. Ashley
Dodd, William B.
Meredith, Wesley O.
Harold, Nicholas J.
Erdem, Cemal
Birtwistle, Marc R.
Mesowestern Blot: Simultaneous Analysis of Hundreds of Submicroliter Lysates
title Mesowestern Blot: Simultaneous Analysis of Hundreds of Submicroliter Lysates
title_full Mesowestern Blot: Simultaneous Analysis of Hundreds of Submicroliter Lysates
title_fullStr Mesowestern Blot: Simultaneous Analysis of Hundreds of Submicroliter Lysates
title_full_unstemmed Mesowestern Blot: Simultaneous Analysis of Hundreds of Submicroliter Lysates
title_short Mesowestern Blot: Simultaneous Analysis of Hundreds of Submicroliter Lysates
title_sort mesowestern blot: simultaneous analysis of hundreds of submicroliter lysates
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9404195/
https://www.ncbi.nlm.nih.gov/pubmed/36033686
http://dx.doi.org/10.1021/acsomega.2c02201
work_keys_str_mv AT zadehcamerono mesowesternblotsimultaneousanalysisofhundredsofsubmicroliterlysates
AT hugginsjonahr mesowesternblotsimultaneousanalysisofhundredsofsubmicroliterlysates
AT sarmahdeepraj mesowesternblotsimultaneousanalysisofhundredsofsubmicroliterlysates
AT westburybayleec mesowesternblotsimultaneousanalysisofhundredsofsubmicroliterlysates
AT interianowilliamr mesowesternblotsimultaneousanalysisofhundredsofsubmicroliterlysates
AT jordanmicahc mesowesternblotsimultaneousanalysisofhundredsofsubmicroliterlysates
AT phillipssashley mesowesternblotsimultaneousanalysisofhundredsofsubmicroliterlysates
AT doddwilliamb mesowesternblotsimultaneousanalysisofhundredsofsubmicroliterlysates
AT meredithwesleyo mesowesternblotsimultaneousanalysisofhundredsofsubmicroliterlysates
AT haroldnicholasj mesowesternblotsimultaneousanalysisofhundredsofsubmicroliterlysates
AT erdemcemal mesowesternblotsimultaneousanalysisofhundredsofsubmicroliterlysates
AT birtwistlemarcr mesowesternblotsimultaneousanalysisofhundredsofsubmicroliterlysates