Cargando…

基于智能手机的便携式毛细管电泳装置检测消毒剂中2种季铵盐

The existing miniature capillary electrophoresis (CE) devices use a tablet or a computer for data processing and analysis, which hinders their portability. In order to solve this problem, a smartphone-based CE device was proposed, which allowed for real portable quantitative analysis. The device int...

Descripción completa

Detalles Bibliográficos
Autores principales: WANG, Yuanyu, ZHANG, Ruihua, ZHANG, Qiang, CAO, Chengxi, FAN, Liuyin, LIU, Weiwen
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Editorial board of Chinese Journal of Chromatography 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9404207/
https://www.ncbi.nlm.nih.gov/pubmed/34677010
http://dx.doi.org/10.3724/SP.J.1123.2021.04030
_version_ 1784773584543023104
author WANG, Yuanyu
ZHANG, Ruihua
ZHANG, Qiang
CAO, Chengxi
FAN, Liuyin
LIU, Weiwen
author_facet WANG, Yuanyu
ZHANG, Ruihua
ZHANG, Qiang
CAO, Chengxi
FAN, Liuyin
LIU, Weiwen
author_sort WANG, Yuanyu
collection PubMed
description The existing miniature capillary electrophoresis (CE) devices use a tablet or a computer for data processing and analysis, which hinders their portability. In order to solve this problem, a smartphone-based CE device was proposed, which allowed for real portable quantitative analysis. The device integrated the functions of capacitively coupled contactless conductivity detection (C(4)D) and Bluetooth communication. Furthermore, a Kotlin language-based application with a user-friendly interface was developed. The application could not only control the electrophoresis run in the CE device but also receive the data from the C(4)D detector in real time, display the electrophoretogram, and process the data. The peak areas could be calculated automatically on the smartphone, and the migration time could be obtained. The size of the developed device was 20 cm×20 cm×15 cm, and its weight was 2 kg. Quaternary ammonium salts (QAs) in disinfectors (dodecyl dimethyl benzyl ammonium bromide (DDBAB) and dodecyl trimethyl ammonium bromide (DTAB)) were used as the analytes to verify the performance of the developed device. The experimental data showed that the linear ranges of DDBAB and DTAB were from 20 to 1000 and from 30 to 1000 μmol/L, respectively. The correlation coefficients (R(2)) of DDBAB and DTAB were 0.9995 and 0.9989, respectively, indicating good linearity between the peak area and concentration. The limits of detection (LODs) of DDBAB and DTAB were 10 and 13 μmol/L, respectively. The intra-day relative standard deviations (RSDs, n=3) of DDBAB and DTAB were 1.9% and 2.7% respectively, revealing good repeatability. In addition, a mixture of DDBAB and DTAB was tested. Two QAs were separated within 8 min, showing good selectivity. Finally, QAs in a bromo geramine disinfector used in the field were tested to further validate the performance of the designed device. The recoveries of DDBAB and DTAB were 100.5%-101.5% and 96.2%-99.3%, respectively, indicating good accuracy. The developed device has the advantages of good linearity, low LOD, good repeatability, high accuracy, and real portability, and it can be used for the quantitative detection of QAs in disinfectors.
format Online
Article
Text
id pubmed-9404207
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Editorial board of Chinese Journal of Chromatography
record_format MEDLINE/PubMed
spelling pubmed-94042072022-09-14 基于智能手机的便携式毛细管电泳装置检测消毒剂中2种季铵盐 WANG, Yuanyu ZHANG, Ruihua ZHANG, Qiang CAO, Chengxi FAN, Liuyin LIU, Weiwen Se Pu Communications The existing miniature capillary electrophoresis (CE) devices use a tablet or a computer for data processing and analysis, which hinders their portability. In order to solve this problem, a smartphone-based CE device was proposed, which allowed for real portable quantitative analysis. The device integrated the functions of capacitively coupled contactless conductivity detection (C(4)D) and Bluetooth communication. Furthermore, a Kotlin language-based application with a user-friendly interface was developed. The application could not only control the electrophoresis run in the CE device but also receive the data from the C(4)D detector in real time, display the electrophoretogram, and process the data. The peak areas could be calculated automatically on the smartphone, and the migration time could be obtained. The size of the developed device was 20 cm×20 cm×15 cm, and its weight was 2 kg. Quaternary ammonium salts (QAs) in disinfectors (dodecyl dimethyl benzyl ammonium bromide (DDBAB) and dodecyl trimethyl ammonium bromide (DTAB)) were used as the analytes to verify the performance of the developed device. The experimental data showed that the linear ranges of DDBAB and DTAB were from 20 to 1000 and from 30 to 1000 μmol/L, respectively. The correlation coefficients (R(2)) of DDBAB and DTAB were 0.9995 and 0.9989, respectively, indicating good linearity between the peak area and concentration. The limits of detection (LODs) of DDBAB and DTAB were 10 and 13 μmol/L, respectively. The intra-day relative standard deviations (RSDs, n=3) of DDBAB and DTAB were 1.9% and 2.7% respectively, revealing good repeatability. In addition, a mixture of DDBAB and DTAB was tested. Two QAs were separated within 8 min, showing good selectivity. Finally, QAs in a bromo geramine disinfector used in the field were tested to further validate the performance of the designed device. The recoveries of DDBAB and DTAB were 100.5%-101.5% and 96.2%-99.3%, respectively, indicating good accuracy. The developed device has the advantages of good linearity, low LOD, good repeatability, high accuracy, and real portability, and it can be used for the quantitative detection of QAs in disinfectors. Editorial board of Chinese Journal of Chromatography 2021-11-08 /pmc/articles/PMC9404207/ /pubmed/34677010 http://dx.doi.org/10.3724/SP.J.1123.2021.04030 Text en https://creativecommons.org/licenses/by/4.0/本文是开放获取文章,遵循CC BY 4.0协议 https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Communications
WANG, Yuanyu
ZHANG, Ruihua
ZHANG, Qiang
CAO, Chengxi
FAN, Liuyin
LIU, Weiwen
基于智能手机的便携式毛细管电泳装置检测消毒剂中2种季铵盐
title 基于智能手机的便携式毛细管电泳装置检测消毒剂中2种季铵盐
title_full 基于智能手机的便携式毛细管电泳装置检测消毒剂中2种季铵盐
title_fullStr 基于智能手机的便携式毛细管电泳装置检测消毒剂中2种季铵盐
title_full_unstemmed 基于智能手机的便携式毛细管电泳装置检测消毒剂中2种季铵盐
title_short 基于智能手机的便携式毛细管电泳装置检测消毒剂中2种季铵盐
title_sort 基于智能手机的便携式毛细管电泳装置检测消毒剂中2种季铵盐
topic Communications
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9404207/
https://www.ncbi.nlm.nih.gov/pubmed/34677010
http://dx.doi.org/10.3724/SP.J.1123.2021.04030
work_keys_str_mv AT wangyuanyu jīyúzhìnéngshǒujīdebiànxiéshìmáoxìguǎndiànyǒngzhuāngzhìjiǎncèxiāodújìzhōng2zhǒngjìǎnyán
AT zhangruihua jīyúzhìnéngshǒujīdebiànxiéshìmáoxìguǎndiànyǒngzhuāngzhìjiǎncèxiāodújìzhōng2zhǒngjìǎnyán
AT zhangqiang jīyúzhìnéngshǒujīdebiànxiéshìmáoxìguǎndiànyǒngzhuāngzhìjiǎncèxiāodújìzhōng2zhǒngjìǎnyán
AT caochengxi jīyúzhìnéngshǒujīdebiànxiéshìmáoxìguǎndiànyǒngzhuāngzhìjiǎncèxiāodújìzhōng2zhǒngjìǎnyán
AT fanliuyin jīyúzhìnéngshǒujīdebiànxiéshìmáoxìguǎndiànyǒngzhuāngzhìjiǎncèxiāodújìzhōng2zhǒngjìǎnyán
AT liuweiwen jīyúzhìnéngshǒujīdebiànxiéshìmáoxìguǎndiànyǒngzhuāngzhìjiǎncèxiāodújìzhōng2zhǒngjìǎnyán