Cargando…

Rapid risk stratification of acute coronary syndrome: adoption of an adapted European Society of Cardiology 0/1-hour troponin algorithm in a real-world setting

AIMS: To evaluate the clinical feasibility of implementing the 2020 ESC 0/1 hr algorithm for rapid rule-out/rule-in of acute coronary syndrome (ACS). METHODS AND RESULTS: Data were collected retrospectively from 5496 patients in 2020 and 7363 patients in 2021 who received cardiac troponin measuremen...

Descripción completa

Detalles Bibliográficos
Autores principales: Couch, Liam S, Sinha, Aish, Navin, Roshan, Hunter, Laura, Perera, Divaka, Marber, Michael S, Kaier, Thomas E
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9404254/
https://www.ncbi.nlm.nih.gov/pubmed/36032815
http://dx.doi.org/10.1093/ehjopen/oeac048
_version_ 1784773599095160832
author Couch, Liam S
Sinha, Aish
Navin, Roshan
Hunter, Laura
Perera, Divaka
Marber, Michael S
Kaier, Thomas E
author_facet Couch, Liam S
Sinha, Aish
Navin, Roshan
Hunter, Laura
Perera, Divaka
Marber, Michael S
Kaier, Thomas E
author_sort Couch, Liam S
collection PubMed
description AIMS: To evaluate the clinical feasibility of implementing the 2020 ESC 0/1 hr algorithm for rapid rule-out/rule-in of acute coronary syndrome (ACS). METHODS AND RESULTS: Data were collected retrospectively from 5496 patients in 2020 and 7363 patients in 2021 who received cardiac troponin measurements through the ACS algorithm in acute care settings within a large tertiary cardiac centre in the United Kingdom. This period overlapped the introduction of the 2020 ESC 0/1 hr algorithm. After exclusion of haemolysis, 1905 patients underwent repeat troponin measurement within the study period in 2020 and 2658 in 2021. Median time to repeat was significantly reduced from 3 h 14 min for intermediate low risk patients (5–12 ng/L) in 2020 to 1 h 22 min in 2021, and from 3 h 30 min to 1 h 59 min in intermediate high-risk patients (12–51 ng/L). Less than 15% of patients requiring repeat testing had dynamic changes in troponin of sufficient magnitude to change their initial risk category. Of all patients, 58.1% of patients in 2020 were ultimately classified as ‘low risk’, 19.2% deemed ‘ACS likely’, and 22.7% as ‘ACS possible’, with similar distributions in 2021. CONCLUSION: Whilst an efficient algorithm, our study demonstrates multi-faceted, practical limitations of achieving the 1 h target for the triage of patients with suspected ACS. Despite challenges predominantly of logistic nature, the algorithm enables rapid, streamlined, and efficient triage of large patient cohorts. Further work is required to streamline this process and achieve the targeted 1 h repeat in a resource-constrained healthcare environment, which would invariably require second blood draw before the result of first, as recommended by the ESC.
format Online
Article
Text
id pubmed-9404254
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-94042542022-08-26 Rapid risk stratification of acute coronary syndrome: adoption of an adapted European Society of Cardiology 0/1-hour troponin algorithm in a real-world setting Couch, Liam S Sinha, Aish Navin, Roshan Hunter, Laura Perera, Divaka Marber, Michael S Kaier, Thomas E Eur Heart J Open Original Article AIMS: To evaluate the clinical feasibility of implementing the 2020 ESC 0/1 hr algorithm for rapid rule-out/rule-in of acute coronary syndrome (ACS). METHODS AND RESULTS: Data were collected retrospectively from 5496 patients in 2020 and 7363 patients in 2021 who received cardiac troponin measurements through the ACS algorithm in acute care settings within a large tertiary cardiac centre in the United Kingdom. This period overlapped the introduction of the 2020 ESC 0/1 hr algorithm. After exclusion of haemolysis, 1905 patients underwent repeat troponin measurement within the study period in 2020 and 2658 in 2021. Median time to repeat was significantly reduced from 3 h 14 min for intermediate low risk patients (5–12 ng/L) in 2020 to 1 h 22 min in 2021, and from 3 h 30 min to 1 h 59 min in intermediate high-risk patients (12–51 ng/L). Less than 15% of patients requiring repeat testing had dynamic changes in troponin of sufficient magnitude to change their initial risk category. Of all patients, 58.1% of patients in 2020 were ultimately classified as ‘low risk’, 19.2% deemed ‘ACS likely’, and 22.7% as ‘ACS possible’, with similar distributions in 2021. CONCLUSION: Whilst an efficient algorithm, our study demonstrates multi-faceted, practical limitations of achieving the 1 h target for the triage of patients with suspected ACS. Despite challenges predominantly of logistic nature, the algorithm enables rapid, streamlined, and efficient triage of large patient cohorts. Further work is required to streamline this process and achieve the targeted 1 h repeat in a resource-constrained healthcare environment, which would invariably require second blood draw before the result of first, as recommended by the ESC. Oxford University Press 2022-07-29 /pmc/articles/PMC9404254/ /pubmed/36032815 http://dx.doi.org/10.1093/ehjopen/oeac048 Text en © The Author(s) 2022. Published by Oxford University Press on behalf of the European Society of Cardiology. https://creativecommons.org/licenses/by/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted reuse, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Couch, Liam S
Sinha, Aish
Navin, Roshan
Hunter, Laura
Perera, Divaka
Marber, Michael S
Kaier, Thomas E
Rapid risk stratification of acute coronary syndrome: adoption of an adapted European Society of Cardiology 0/1-hour troponin algorithm in a real-world setting
title Rapid risk stratification of acute coronary syndrome: adoption of an adapted European Society of Cardiology 0/1-hour troponin algorithm in a real-world setting
title_full Rapid risk stratification of acute coronary syndrome: adoption of an adapted European Society of Cardiology 0/1-hour troponin algorithm in a real-world setting
title_fullStr Rapid risk stratification of acute coronary syndrome: adoption of an adapted European Society of Cardiology 0/1-hour troponin algorithm in a real-world setting
title_full_unstemmed Rapid risk stratification of acute coronary syndrome: adoption of an adapted European Society of Cardiology 0/1-hour troponin algorithm in a real-world setting
title_short Rapid risk stratification of acute coronary syndrome: adoption of an adapted European Society of Cardiology 0/1-hour troponin algorithm in a real-world setting
title_sort rapid risk stratification of acute coronary syndrome: adoption of an adapted european society of cardiology 0/1-hour troponin algorithm in a real-world setting
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9404254/
https://www.ncbi.nlm.nih.gov/pubmed/36032815
http://dx.doi.org/10.1093/ehjopen/oeac048
work_keys_str_mv AT couchliams rapidriskstratificationofacutecoronarysyndromeadoptionofanadaptedeuropeansocietyofcardiology01hourtroponinalgorithminarealworldsetting
AT sinhaaish rapidriskstratificationofacutecoronarysyndromeadoptionofanadaptedeuropeansocietyofcardiology01hourtroponinalgorithminarealworldsetting
AT navinroshan rapidriskstratificationofacutecoronarysyndromeadoptionofanadaptedeuropeansocietyofcardiology01hourtroponinalgorithminarealworldsetting
AT hunterlaura rapidriskstratificationofacutecoronarysyndromeadoptionofanadaptedeuropeansocietyofcardiology01hourtroponinalgorithminarealworldsetting
AT pereradivaka rapidriskstratificationofacutecoronarysyndromeadoptionofanadaptedeuropeansocietyofcardiology01hourtroponinalgorithminarealworldsetting
AT marbermichaels rapidriskstratificationofacutecoronarysyndromeadoptionofanadaptedeuropeansocietyofcardiology01hourtroponinalgorithminarealworldsetting
AT kaierthomase rapidriskstratificationofacutecoronarysyndromeadoptionofanadaptedeuropeansocietyofcardiology01hourtroponinalgorithminarealworldsetting