Mechanical Testing of the New Cage for Tibial Tuberosity Advancement with the Cranial Implant Fixation (TTA CF) Technique—Ex Vivo Study on Sheep Model

SIMPLE SUMMARY: Tibial tuberosity advancement is a method of surgical treatment of cranial cruciate ligament rupture in animals.. In previous reports, the biomechanical effectiveness of tibial tuberosity advancement surgeries was evaluated by axial pressure on the tibial tuberosity to test the stren...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhalniarovich, Yauheni, Przyborowska-Zhalniarovich, Paulina, Tobolska, Angelika, Mieszkowska, Marta, Abako, Justyna, Morawska-Kozłowska, Magdalena, Mieszkowski, Marcin, Onichimowski, Dariusz
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9404418/
https://www.ncbi.nlm.nih.gov/pubmed/36009606
http://dx.doi.org/10.3390/ani12162013
_version_ 1784773633930952704
author Zhalniarovich, Yauheni
Przyborowska-Zhalniarovich, Paulina
Tobolska, Angelika
Mieszkowska, Marta
Abako, Justyna
Morawska-Kozłowska, Magdalena
Mieszkowski, Marcin
Onichimowski, Dariusz
author_facet Zhalniarovich, Yauheni
Przyborowska-Zhalniarovich, Paulina
Tobolska, Angelika
Mieszkowska, Marta
Abako, Justyna
Morawska-Kozłowska, Magdalena
Mieszkowski, Marcin
Onichimowski, Dariusz
author_sort Zhalniarovich, Yauheni
collection PubMed
description SIMPLE SUMMARY: Tibial tuberosity advancement is a method of surgical treatment of cranial cruciate ligament rupture in animals.. In previous reports, the biomechanical effectiveness of tibial tuberosity advancement surgeries was evaluated by axial pressure on the tibial tuberosity to test the strength and resistance of the fixation or by pulling on the tuberosity. To our knowledge, there are no reports that examined the strength that is needed to pull out an implant from the tibia after tibial advancement. This study is the first report that focuses on pulling out the TTA implant, which corresponds to the biointegrity and ingrowth of the TTA cage with the tibia. ABSTRACT: Background: Modifications of tibial tuberosity advancement are well accepted for cranial cruciate rupture repair. We compared the loads that were needed to pull the TTA CF cage out in the two groups. The first group consisted of five sheep in which osteotomy and TTA CF cage fixation were performed as assumed preoperatively. The second group consisted of five sheep in which intraoperative or postoperative discrepancies from preoperative planning were found. This is also the first report describing biomechanical testing after tibial tuberosity advancement with cranial implant fixation (TTA CF) surgical procedures. Results: A total of 10 ovine proximal tibiae were tested biomechanically by tearing out TTA CF implants from the bone. The mean maximal loaded forces to pull out the cage in Group 1, in which fixation of the implant was performed as assumed preoperatively, was 878 ± 61 N, and in Group 2, in which discrepancies from preoperative planning were found, was 330 ± 55 N. The mean implant displacement under maximal load to failure was 2.6 mm and 2.2 mm in Groups 1 and 2, respectively. There was a significant difference between Group 1 and Group 2 in the maximal loads-to-failure; however, the difference in the displacement at maximal loaded forces to pull out the cage was not significant between the groups. Conclusions: The mean maximal loaded forces to pull out the cage was significantly lower in Group 2, where discrepancies from preoperative planning were found (878 ± 61 N vs. 330 ± 55 N). The lower forces that were needed to extract the TTA CF implant from the tibia can lead to the conclusion that biointegration of the implant is also weaker. Correct positioning of the osteotomy line and TTA CF implant is essential for good biointegrity and thus for limiting complications in the form of tibial tuberosity avulsion fracture or tibial shaft fracture.
format Online
Article
Text
id pubmed-9404418
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-94044182022-08-26 Mechanical Testing of the New Cage for Tibial Tuberosity Advancement with the Cranial Implant Fixation (TTA CF) Technique—Ex Vivo Study on Sheep Model Zhalniarovich, Yauheni Przyborowska-Zhalniarovich, Paulina Tobolska, Angelika Mieszkowska, Marta Abako, Justyna Morawska-Kozłowska, Magdalena Mieszkowski, Marcin Onichimowski, Dariusz Animals (Basel) Article SIMPLE SUMMARY: Tibial tuberosity advancement is a method of surgical treatment of cranial cruciate ligament rupture in animals.. In previous reports, the biomechanical effectiveness of tibial tuberosity advancement surgeries was evaluated by axial pressure on the tibial tuberosity to test the strength and resistance of the fixation or by pulling on the tuberosity. To our knowledge, there are no reports that examined the strength that is needed to pull out an implant from the tibia after tibial advancement. This study is the first report that focuses on pulling out the TTA implant, which corresponds to the biointegrity and ingrowth of the TTA cage with the tibia. ABSTRACT: Background: Modifications of tibial tuberosity advancement are well accepted for cranial cruciate rupture repair. We compared the loads that were needed to pull the TTA CF cage out in the two groups. The first group consisted of five sheep in which osteotomy and TTA CF cage fixation were performed as assumed preoperatively. The second group consisted of five sheep in which intraoperative or postoperative discrepancies from preoperative planning were found. This is also the first report describing biomechanical testing after tibial tuberosity advancement with cranial implant fixation (TTA CF) surgical procedures. Results: A total of 10 ovine proximal tibiae were tested biomechanically by tearing out TTA CF implants from the bone. The mean maximal loaded forces to pull out the cage in Group 1, in which fixation of the implant was performed as assumed preoperatively, was 878 ± 61 N, and in Group 2, in which discrepancies from preoperative planning were found, was 330 ± 55 N. The mean implant displacement under maximal load to failure was 2.6 mm and 2.2 mm in Groups 1 and 2, respectively. There was a significant difference between Group 1 and Group 2 in the maximal loads-to-failure; however, the difference in the displacement at maximal loaded forces to pull out the cage was not significant between the groups. Conclusions: The mean maximal loaded forces to pull out the cage was significantly lower in Group 2, where discrepancies from preoperative planning were found (878 ± 61 N vs. 330 ± 55 N). The lower forces that were needed to extract the TTA CF implant from the tibia can lead to the conclusion that biointegration of the implant is also weaker. Correct positioning of the osteotomy line and TTA CF implant is essential for good biointegrity and thus for limiting complications in the form of tibial tuberosity avulsion fracture or tibial shaft fracture. MDPI 2022-08-09 /pmc/articles/PMC9404418/ /pubmed/36009606 http://dx.doi.org/10.3390/ani12162013 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Zhalniarovich, Yauheni
Przyborowska-Zhalniarovich, Paulina
Tobolska, Angelika
Mieszkowska, Marta
Abako, Justyna
Morawska-Kozłowska, Magdalena
Mieszkowski, Marcin
Onichimowski, Dariusz
Mechanical Testing of the New Cage for Tibial Tuberosity Advancement with the Cranial Implant Fixation (TTA CF) Technique—Ex Vivo Study on Sheep Model
title Mechanical Testing of the New Cage for Tibial Tuberosity Advancement with the Cranial Implant Fixation (TTA CF) Technique—Ex Vivo Study on Sheep Model
title_full Mechanical Testing of the New Cage for Tibial Tuberosity Advancement with the Cranial Implant Fixation (TTA CF) Technique—Ex Vivo Study on Sheep Model
title_fullStr Mechanical Testing of the New Cage for Tibial Tuberosity Advancement with the Cranial Implant Fixation (TTA CF) Technique—Ex Vivo Study on Sheep Model
title_full_unstemmed Mechanical Testing of the New Cage for Tibial Tuberosity Advancement with the Cranial Implant Fixation (TTA CF) Technique—Ex Vivo Study on Sheep Model
title_short Mechanical Testing of the New Cage for Tibial Tuberosity Advancement with the Cranial Implant Fixation (TTA CF) Technique—Ex Vivo Study on Sheep Model
title_sort mechanical testing of the new cage for tibial tuberosity advancement with the cranial implant fixation (tta cf) technique—ex vivo study on sheep model
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9404418/
https://www.ncbi.nlm.nih.gov/pubmed/36009606
http://dx.doi.org/10.3390/ani12162013
work_keys_str_mv AT zhalniarovichyauheni mechanicaltestingofthenewcagefortibialtuberosityadvancementwiththecranialimplantfixationttacftechniqueexvivostudyonsheepmodel
AT przyborowskazhalniarovichpaulina mechanicaltestingofthenewcagefortibialtuberosityadvancementwiththecranialimplantfixationttacftechniqueexvivostudyonsheepmodel
AT tobolskaangelika mechanicaltestingofthenewcagefortibialtuberosityadvancementwiththecranialimplantfixationttacftechniqueexvivostudyonsheepmodel
AT mieszkowskamarta mechanicaltestingofthenewcagefortibialtuberosityadvancementwiththecranialimplantfixationttacftechniqueexvivostudyonsheepmodel
AT abakojustyna mechanicaltestingofthenewcagefortibialtuberosityadvancementwiththecranialimplantfixationttacftechniqueexvivostudyonsheepmodel
AT morawskakozłowskamagdalena mechanicaltestingofthenewcagefortibialtuberosityadvancementwiththecranialimplantfixationttacftechniqueexvivostudyonsheepmodel
AT mieszkowskimarcin mechanicaltestingofthenewcagefortibialtuberosityadvancementwiththecranialimplantfixationttacftechniqueexvivostudyonsheepmodel
AT onichimowskidariusz mechanicaltestingofthenewcagefortibialtuberosityadvancementwiththecranialimplantfixationttacftechniqueexvivostudyonsheepmodel