Cargando…

A Redox-Probe-Free Immunosensor Based on Electrocatalytic Prussian Blue Nanostructured Film One-Step-Prepared for Zika Virus Diagnosis

The Zika virus (ZIKV) is a great concern for global health due to its high transmission, including disseminating through blood, saliva, urine, semen and vertical transmission. In some cases, ZIKV has been associated with microcephaly, neurological disorders, and Guillain–Barré syndrome. There is no...

Descripción completa

Detalles Bibliográficos
Autores principales: Santos, Lorenna K. B., Mendonça, Priscila D., Assis, LiLian K. S., Prudêncio, Carlos R., Guedes, Maria Izabel F., Marques, Ernesto T. A., Dutra, Rosa Fireman
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9406047/
https://www.ncbi.nlm.nih.gov/pubmed/36005020
http://dx.doi.org/10.3390/bios12080623
_version_ 1784774028078088192
author Santos, Lorenna K. B.
Mendonça, Priscila D.
Assis, LiLian K. S.
Prudêncio, Carlos R.
Guedes, Maria Izabel F.
Marques, Ernesto T. A.
Dutra, Rosa Fireman
author_facet Santos, Lorenna K. B.
Mendonça, Priscila D.
Assis, LiLian K. S.
Prudêncio, Carlos R.
Guedes, Maria Izabel F.
Marques, Ernesto T. A.
Dutra, Rosa Fireman
author_sort Santos, Lorenna K. B.
collection PubMed
description The Zika virus (ZIKV) is a great concern for global health due to its high transmission, including disseminating through blood, saliva, urine, semen and vertical transmission. In some cases, ZIKV has been associated with microcephaly, neurological disorders, and Guillain–Barré syndrome. There is no vaccine, and controlling the disease is a challenge, especially with the co-circulation of the Dengue virus, which causes a severe cross-reaction due to the similarity between the two arboviruses. Considering that electrochemical immunosensors are well-established, sensitive, and practical tools for diagnosis, in this study we developed a sensor platform with intrinsic redox activity that facilitates measurement readouts. Prussian blue (PB) has a great ability to form electrocatalytic surfaces, dispensing redox probe solutions in voltammetric measurements. Herein, PB was incorporated into a chitosan–carbon nanotube hybrid, forming a nanocomposite that was drop-casted on a screen-printed electrode (SPE). The immunosensor detected the envelope protein of ZIKV in a linear range of 0.25 to 1.75 µg/mL (n = 8, p < 0.01), with a 0.20 µg/mL limit of detection. The developed immunosensor represents a new method for electrochemical measurements without additional redox probe solutions, and it is feasible for application in point-of-care diagnosis.
format Online
Article
Text
id pubmed-9406047
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-94060472022-08-26 A Redox-Probe-Free Immunosensor Based on Electrocatalytic Prussian Blue Nanostructured Film One-Step-Prepared for Zika Virus Diagnosis Santos, Lorenna K. B. Mendonça, Priscila D. Assis, LiLian K. S. Prudêncio, Carlos R. Guedes, Maria Izabel F. Marques, Ernesto T. A. Dutra, Rosa Fireman Biosensors (Basel) Article The Zika virus (ZIKV) is a great concern for global health due to its high transmission, including disseminating through blood, saliva, urine, semen and vertical transmission. In some cases, ZIKV has been associated with microcephaly, neurological disorders, and Guillain–Barré syndrome. There is no vaccine, and controlling the disease is a challenge, especially with the co-circulation of the Dengue virus, which causes a severe cross-reaction due to the similarity between the two arboviruses. Considering that electrochemical immunosensors are well-established, sensitive, and practical tools for diagnosis, in this study we developed a sensor platform with intrinsic redox activity that facilitates measurement readouts. Prussian blue (PB) has a great ability to form electrocatalytic surfaces, dispensing redox probe solutions in voltammetric measurements. Herein, PB was incorporated into a chitosan–carbon nanotube hybrid, forming a nanocomposite that was drop-casted on a screen-printed electrode (SPE). The immunosensor detected the envelope protein of ZIKV in a linear range of 0.25 to 1.75 µg/mL (n = 8, p < 0.01), with a 0.20 µg/mL limit of detection. The developed immunosensor represents a new method for electrochemical measurements without additional redox probe solutions, and it is feasible for application in point-of-care diagnosis. MDPI 2022-08-10 /pmc/articles/PMC9406047/ /pubmed/36005020 http://dx.doi.org/10.3390/bios12080623 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Santos, Lorenna K. B.
Mendonça, Priscila D.
Assis, LiLian K. S.
Prudêncio, Carlos R.
Guedes, Maria Izabel F.
Marques, Ernesto T. A.
Dutra, Rosa Fireman
A Redox-Probe-Free Immunosensor Based on Electrocatalytic Prussian Blue Nanostructured Film One-Step-Prepared for Zika Virus Diagnosis
title A Redox-Probe-Free Immunosensor Based on Electrocatalytic Prussian Blue Nanostructured Film One-Step-Prepared for Zika Virus Diagnosis
title_full A Redox-Probe-Free Immunosensor Based on Electrocatalytic Prussian Blue Nanostructured Film One-Step-Prepared for Zika Virus Diagnosis
title_fullStr A Redox-Probe-Free Immunosensor Based on Electrocatalytic Prussian Blue Nanostructured Film One-Step-Prepared for Zika Virus Diagnosis
title_full_unstemmed A Redox-Probe-Free Immunosensor Based on Electrocatalytic Prussian Blue Nanostructured Film One-Step-Prepared for Zika Virus Diagnosis
title_short A Redox-Probe-Free Immunosensor Based on Electrocatalytic Prussian Blue Nanostructured Film One-Step-Prepared for Zika Virus Diagnosis
title_sort redox-probe-free immunosensor based on electrocatalytic prussian blue nanostructured film one-step-prepared for zika virus diagnosis
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9406047/
https://www.ncbi.nlm.nih.gov/pubmed/36005020
http://dx.doi.org/10.3390/bios12080623
work_keys_str_mv AT santoslorennakb aredoxprobefreeimmunosensorbasedonelectrocatalyticprussianbluenanostructuredfilmonesteppreparedforzikavirusdiagnosis
AT mendoncapriscilad aredoxprobefreeimmunosensorbasedonelectrocatalyticprussianbluenanostructuredfilmonesteppreparedforzikavirusdiagnosis
AT assislilianks aredoxprobefreeimmunosensorbasedonelectrocatalyticprussianbluenanostructuredfilmonesteppreparedforzikavirusdiagnosis
AT prudenciocarlosr aredoxprobefreeimmunosensorbasedonelectrocatalyticprussianbluenanostructuredfilmonesteppreparedforzikavirusdiagnosis
AT guedesmariaizabelf aredoxprobefreeimmunosensorbasedonelectrocatalyticprussianbluenanostructuredfilmonesteppreparedforzikavirusdiagnosis
AT marquesernestota aredoxprobefreeimmunosensorbasedonelectrocatalyticprussianbluenanostructuredfilmonesteppreparedforzikavirusdiagnosis
AT dutrarosafireman aredoxprobefreeimmunosensorbasedonelectrocatalyticprussianbluenanostructuredfilmonesteppreparedforzikavirusdiagnosis
AT santoslorennakb redoxprobefreeimmunosensorbasedonelectrocatalyticprussianbluenanostructuredfilmonesteppreparedforzikavirusdiagnosis
AT mendoncapriscilad redoxprobefreeimmunosensorbasedonelectrocatalyticprussianbluenanostructuredfilmonesteppreparedforzikavirusdiagnosis
AT assislilianks redoxprobefreeimmunosensorbasedonelectrocatalyticprussianbluenanostructuredfilmonesteppreparedforzikavirusdiagnosis
AT prudenciocarlosr redoxprobefreeimmunosensorbasedonelectrocatalyticprussianbluenanostructuredfilmonesteppreparedforzikavirusdiagnosis
AT guedesmariaizabelf redoxprobefreeimmunosensorbasedonelectrocatalyticprussianbluenanostructuredfilmonesteppreparedforzikavirusdiagnosis
AT marquesernestota redoxprobefreeimmunosensorbasedonelectrocatalyticprussianbluenanostructuredfilmonesteppreparedforzikavirusdiagnosis
AT dutrarosafireman redoxprobefreeimmunosensorbasedonelectrocatalyticprussianbluenanostructuredfilmonesteppreparedforzikavirusdiagnosis