Cargando…
Detecting Endotracheal Tube and Carina on Portable Supine Chest Radiographs Using One-Stage Detector with a Coarse-to-Fine Attention
In intensive care units (ICUs), after endotracheal intubation, the position of the endotracheal tube (ETT) should be checked to avoid complications. The malposition can be detected by the distance between the ETT tip and the Carina (ETT–Carina distance). However, it struggles with a limited performa...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9406505/ https://www.ncbi.nlm.nih.gov/pubmed/36010263 http://dx.doi.org/10.3390/diagnostics12081913 |
_version_ | 1784774137555714048 |
---|---|
author | Mao, Liang-Kai Huang, Min-Hsin Lai, Chao-Han Sun, Yung-Nien Chen, Chi-Yeh |
author_facet | Mao, Liang-Kai Huang, Min-Hsin Lai, Chao-Han Sun, Yung-Nien Chen, Chi-Yeh |
author_sort | Mao, Liang-Kai |
collection | PubMed |
description | In intensive care units (ICUs), after endotracheal intubation, the position of the endotracheal tube (ETT) should be checked to avoid complications. The malposition can be detected by the distance between the ETT tip and the Carina (ETT–Carina distance). However, it struggles with a limited performance for two major problems, i.e., occlusion by external machine, and the posture and machine of taking chest radiographs. While previous studies addressed these problems, they always suffered from the requirements of manual intervention. Therefore, the purpose of this paper is to locate the ETT tip and the Carina more accurately for detecting the malposition without manual intervention. The proposed architecture is composed of FCOS: Fully Convolutional One-Stage Object Detection, an attention mechanism named Coarse-to-Fine Attention (CTFA), and a segmentation branch. Moreover, a post-process algorithm is adopted to select the final location of the ETT tip and the Carina. Three metrics were used to evaluate the performance of the proposed method. With the dataset provided by National Cheng Kung University Hospital, the accuracy of the malposition detected by the proposed method achieves [Formula: see text] and the ETT–Carina distance errors are less than [Formula: see text] mm. |
format | Online Article Text |
id | pubmed-9406505 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-94065052022-08-26 Detecting Endotracheal Tube and Carina on Portable Supine Chest Radiographs Using One-Stage Detector with a Coarse-to-Fine Attention Mao, Liang-Kai Huang, Min-Hsin Lai, Chao-Han Sun, Yung-Nien Chen, Chi-Yeh Diagnostics (Basel) Article In intensive care units (ICUs), after endotracheal intubation, the position of the endotracheal tube (ETT) should be checked to avoid complications. The malposition can be detected by the distance between the ETT tip and the Carina (ETT–Carina distance). However, it struggles with a limited performance for two major problems, i.e., occlusion by external machine, and the posture and machine of taking chest radiographs. While previous studies addressed these problems, they always suffered from the requirements of manual intervention. Therefore, the purpose of this paper is to locate the ETT tip and the Carina more accurately for detecting the malposition without manual intervention. The proposed architecture is composed of FCOS: Fully Convolutional One-Stage Object Detection, an attention mechanism named Coarse-to-Fine Attention (CTFA), and a segmentation branch. Moreover, a post-process algorithm is adopted to select the final location of the ETT tip and the Carina. Three metrics were used to evaluate the performance of the proposed method. With the dataset provided by National Cheng Kung University Hospital, the accuracy of the malposition detected by the proposed method achieves [Formula: see text] and the ETT–Carina distance errors are less than [Formula: see text] mm. MDPI 2022-08-07 /pmc/articles/PMC9406505/ /pubmed/36010263 http://dx.doi.org/10.3390/diagnostics12081913 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Mao, Liang-Kai Huang, Min-Hsin Lai, Chao-Han Sun, Yung-Nien Chen, Chi-Yeh Detecting Endotracheal Tube and Carina on Portable Supine Chest Radiographs Using One-Stage Detector with a Coarse-to-Fine Attention |
title | Detecting Endotracheal Tube and Carina on Portable Supine Chest Radiographs Using One-Stage Detector with a Coarse-to-Fine Attention |
title_full | Detecting Endotracheal Tube and Carina on Portable Supine Chest Radiographs Using One-Stage Detector with a Coarse-to-Fine Attention |
title_fullStr | Detecting Endotracheal Tube and Carina on Portable Supine Chest Radiographs Using One-Stage Detector with a Coarse-to-Fine Attention |
title_full_unstemmed | Detecting Endotracheal Tube and Carina on Portable Supine Chest Radiographs Using One-Stage Detector with a Coarse-to-Fine Attention |
title_short | Detecting Endotracheal Tube and Carina on Portable Supine Chest Radiographs Using One-Stage Detector with a Coarse-to-Fine Attention |
title_sort | detecting endotracheal tube and carina on portable supine chest radiographs using one-stage detector with a coarse-to-fine attention |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9406505/ https://www.ncbi.nlm.nih.gov/pubmed/36010263 http://dx.doi.org/10.3390/diagnostics12081913 |
work_keys_str_mv | AT maoliangkai detectingendotrachealtubeandcarinaonportablesupinechestradiographsusingonestagedetectorwithacoarsetofineattention AT huangminhsin detectingendotrachealtubeandcarinaonportablesupinechestradiographsusingonestagedetectorwithacoarsetofineattention AT laichaohan detectingendotrachealtubeandcarinaonportablesupinechestradiographsusingonestagedetectorwithacoarsetofineattention AT sunyungnien detectingendotrachealtubeandcarinaonportablesupinechestradiographsusingonestagedetectorwithacoarsetofineattention AT chenchiyeh detectingendotrachealtubeandcarinaonportablesupinechestradiographsusingonestagedetectorwithacoarsetofineattention |