Cargando…

Detecting Endotracheal Tube and Carina on Portable Supine Chest Radiographs Using One-Stage Detector with a Coarse-to-Fine Attention

In intensive care units (ICUs), after endotracheal intubation, the position of the endotracheal tube (ETT) should be checked to avoid complications. The malposition can be detected by the distance between the ETT tip and the Carina (ETT–Carina distance). However, it struggles with a limited performa...

Descripción completa

Detalles Bibliográficos
Autores principales: Mao, Liang-Kai, Huang, Min-Hsin, Lai, Chao-Han, Sun, Yung-Nien, Chen, Chi-Yeh
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9406505/
https://www.ncbi.nlm.nih.gov/pubmed/36010263
http://dx.doi.org/10.3390/diagnostics12081913
_version_ 1784774137555714048
author Mao, Liang-Kai
Huang, Min-Hsin
Lai, Chao-Han
Sun, Yung-Nien
Chen, Chi-Yeh
author_facet Mao, Liang-Kai
Huang, Min-Hsin
Lai, Chao-Han
Sun, Yung-Nien
Chen, Chi-Yeh
author_sort Mao, Liang-Kai
collection PubMed
description In intensive care units (ICUs), after endotracheal intubation, the position of the endotracheal tube (ETT) should be checked to avoid complications. The malposition can be detected by the distance between the ETT tip and the Carina (ETT–Carina distance). However, it struggles with a limited performance for two major problems, i.e., occlusion by external machine, and the posture and machine of taking chest radiographs. While previous studies addressed these problems, they always suffered from the requirements of manual intervention. Therefore, the purpose of this paper is to locate the ETT tip and the Carina more accurately for detecting the malposition without manual intervention. The proposed architecture is composed of FCOS: Fully Convolutional One-Stage Object Detection, an attention mechanism named Coarse-to-Fine Attention (CTFA), and a segmentation branch. Moreover, a post-process algorithm is adopted to select the final location of the ETT tip and the Carina. Three metrics were used to evaluate the performance of the proposed method. With the dataset provided by National Cheng Kung University Hospital, the accuracy of the malposition detected by the proposed method achieves [Formula: see text] and the ETT–Carina distance errors are less than [Formula: see text] mm.
format Online
Article
Text
id pubmed-9406505
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-94065052022-08-26 Detecting Endotracheal Tube and Carina on Portable Supine Chest Radiographs Using One-Stage Detector with a Coarse-to-Fine Attention Mao, Liang-Kai Huang, Min-Hsin Lai, Chao-Han Sun, Yung-Nien Chen, Chi-Yeh Diagnostics (Basel) Article In intensive care units (ICUs), after endotracheal intubation, the position of the endotracheal tube (ETT) should be checked to avoid complications. The malposition can be detected by the distance between the ETT tip and the Carina (ETT–Carina distance). However, it struggles with a limited performance for two major problems, i.e., occlusion by external machine, and the posture and machine of taking chest radiographs. While previous studies addressed these problems, they always suffered from the requirements of manual intervention. Therefore, the purpose of this paper is to locate the ETT tip and the Carina more accurately for detecting the malposition without manual intervention. The proposed architecture is composed of FCOS: Fully Convolutional One-Stage Object Detection, an attention mechanism named Coarse-to-Fine Attention (CTFA), and a segmentation branch. Moreover, a post-process algorithm is adopted to select the final location of the ETT tip and the Carina. Three metrics were used to evaluate the performance of the proposed method. With the dataset provided by National Cheng Kung University Hospital, the accuracy of the malposition detected by the proposed method achieves [Formula: see text] and the ETT–Carina distance errors are less than [Formula: see text] mm. MDPI 2022-08-07 /pmc/articles/PMC9406505/ /pubmed/36010263 http://dx.doi.org/10.3390/diagnostics12081913 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Mao, Liang-Kai
Huang, Min-Hsin
Lai, Chao-Han
Sun, Yung-Nien
Chen, Chi-Yeh
Detecting Endotracheal Tube and Carina on Portable Supine Chest Radiographs Using One-Stage Detector with a Coarse-to-Fine Attention
title Detecting Endotracheal Tube and Carina on Portable Supine Chest Radiographs Using One-Stage Detector with a Coarse-to-Fine Attention
title_full Detecting Endotracheal Tube and Carina on Portable Supine Chest Radiographs Using One-Stage Detector with a Coarse-to-Fine Attention
title_fullStr Detecting Endotracheal Tube and Carina on Portable Supine Chest Radiographs Using One-Stage Detector with a Coarse-to-Fine Attention
title_full_unstemmed Detecting Endotracheal Tube and Carina on Portable Supine Chest Radiographs Using One-Stage Detector with a Coarse-to-Fine Attention
title_short Detecting Endotracheal Tube and Carina on Portable Supine Chest Radiographs Using One-Stage Detector with a Coarse-to-Fine Attention
title_sort detecting endotracheal tube and carina on portable supine chest radiographs using one-stage detector with a coarse-to-fine attention
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9406505/
https://www.ncbi.nlm.nih.gov/pubmed/36010263
http://dx.doi.org/10.3390/diagnostics12081913
work_keys_str_mv AT maoliangkai detectingendotrachealtubeandcarinaonportablesupinechestradiographsusingonestagedetectorwithacoarsetofineattention
AT huangminhsin detectingendotrachealtubeandcarinaonportablesupinechestradiographsusingonestagedetectorwithacoarsetofineattention
AT laichaohan detectingendotrachealtubeandcarinaonportablesupinechestradiographsusingonestagedetectorwithacoarsetofineattention
AT sunyungnien detectingendotrachealtubeandcarinaonportablesupinechestradiographsusingonestagedetectorwithacoarsetofineattention
AT chenchiyeh detectingendotrachealtubeandcarinaonportablesupinechestradiographsusingonestagedetectorwithacoarsetofineattention