Cargando…
STANDARD M10 SARS-CoV-2 Assay for Rapid Detection of SARS-CoV-2: Comparison of Four Real-Time PCR Assays
The demand for assays that can rapidly and accurately detect severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) remains high. We evaluated the performance of two rapid real-time reverse transcription polymerase chain reaction (RT-qPCR) assays (STANDARD M10 SARS-CoV-2 and Xpert Xpress SARS-...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9406901/ https://www.ncbi.nlm.nih.gov/pubmed/36010348 http://dx.doi.org/10.3390/diagnostics12081998 |
_version_ | 1784774234516488192 |
---|---|
author | Jeong, Seri Lee, Nuri Lee, Su Kyung Cho, Eun-Jung Hyun, Jungwon Park, Min-Jeong Song, Wonkeun Kim, Hyun Soo |
author_facet | Jeong, Seri Lee, Nuri Lee, Su Kyung Cho, Eun-Jung Hyun, Jungwon Park, Min-Jeong Song, Wonkeun Kim, Hyun Soo |
author_sort | Jeong, Seri |
collection | PubMed |
description | The demand for assays that can rapidly and accurately detect severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) remains high. We evaluated the performance of two rapid real-time reverse transcription polymerase chain reaction (RT-qPCR) assays (STANDARD M10 SARS-CoV-2 and Xpert Xpress SARS-CoV-2) against conventional RT-qPCR assays (STANDARD M nCoV and Allplex SARS-CoV-2) for detecting SARS-CoV-2. A total of 225 swab samples were collected and tested using the four assays. The STANDARD M10 SARS-CoV-2 assay showed 97.4% positive percent agreement (PPA) and 100.0% negative percent agreement (NPA) compared to the STANDARD M nCoV assay and Allplex SARS-CoV-2 assay. STANDARD M10 exhibited high performance except in samples with low viral loads (cycle threshold (Ct) > 30). Xpert Xpress showed PPA and NPA of 100.0% compared to the two conventional RT-qPCR assays. The kappa coefficient (Κ) showed nearly almost perfect agreement between each assay and conventional RT-qPCR assays. The correlations of Ct values between the two rapid RT-qPCR and conventional RT-qPCR assays were >0.8, indicating strong correlations. All included assays could detect SARS-CoV-2 variants, such as the Alpha, Beta, and Gamma variants. The recently developed STANDARD M10 has a shorter turnaround time and random-access detection on automated devices, thereby facilitating efficient testing in emergency settings. |
format | Online Article Text |
id | pubmed-9406901 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-94069012022-08-26 STANDARD M10 SARS-CoV-2 Assay for Rapid Detection of SARS-CoV-2: Comparison of Four Real-Time PCR Assays Jeong, Seri Lee, Nuri Lee, Su Kyung Cho, Eun-Jung Hyun, Jungwon Park, Min-Jeong Song, Wonkeun Kim, Hyun Soo Diagnostics (Basel) Article The demand for assays that can rapidly and accurately detect severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) remains high. We evaluated the performance of two rapid real-time reverse transcription polymerase chain reaction (RT-qPCR) assays (STANDARD M10 SARS-CoV-2 and Xpert Xpress SARS-CoV-2) against conventional RT-qPCR assays (STANDARD M nCoV and Allplex SARS-CoV-2) for detecting SARS-CoV-2. A total of 225 swab samples were collected and tested using the four assays. The STANDARD M10 SARS-CoV-2 assay showed 97.4% positive percent agreement (PPA) and 100.0% negative percent agreement (NPA) compared to the STANDARD M nCoV assay and Allplex SARS-CoV-2 assay. STANDARD M10 exhibited high performance except in samples with low viral loads (cycle threshold (Ct) > 30). Xpert Xpress showed PPA and NPA of 100.0% compared to the two conventional RT-qPCR assays. The kappa coefficient (Κ) showed nearly almost perfect agreement between each assay and conventional RT-qPCR assays. The correlations of Ct values between the two rapid RT-qPCR and conventional RT-qPCR assays were >0.8, indicating strong correlations. All included assays could detect SARS-CoV-2 variants, such as the Alpha, Beta, and Gamma variants. The recently developed STANDARD M10 has a shorter turnaround time and random-access detection on automated devices, thereby facilitating efficient testing in emergency settings. MDPI 2022-08-18 /pmc/articles/PMC9406901/ /pubmed/36010348 http://dx.doi.org/10.3390/diagnostics12081998 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Jeong, Seri Lee, Nuri Lee, Su Kyung Cho, Eun-Jung Hyun, Jungwon Park, Min-Jeong Song, Wonkeun Kim, Hyun Soo STANDARD M10 SARS-CoV-2 Assay for Rapid Detection of SARS-CoV-2: Comparison of Four Real-Time PCR Assays |
title | STANDARD M10 SARS-CoV-2 Assay for Rapid Detection of SARS-CoV-2: Comparison of Four Real-Time PCR Assays |
title_full | STANDARD M10 SARS-CoV-2 Assay for Rapid Detection of SARS-CoV-2: Comparison of Four Real-Time PCR Assays |
title_fullStr | STANDARD M10 SARS-CoV-2 Assay for Rapid Detection of SARS-CoV-2: Comparison of Four Real-Time PCR Assays |
title_full_unstemmed | STANDARD M10 SARS-CoV-2 Assay for Rapid Detection of SARS-CoV-2: Comparison of Four Real-Time PCR Assays |
title_short | STANDARD M10 SARS-CoV-2 Assay for Rapid Detection of SARS-CoV-2: Comparison of Four Real-Time PCR Assays |
title_sort | standard m10 sars-cov-2 assay for rapid detection of sars-cov-2: comparison of four real-time pcr assays |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9406901/ https://www.ncbi.nlm.nih.gov/pubmed/36010348 http://dx.doi.org/10.3390/diagnostics12081998 |
work_keys_str_mv | AT jeongseri standardm10sarscov2assayforrapiddetectionofsarscov2comparisonoffourrealtimepcrassays AT leenuri standardm10sarscov2assayforrapiddetectionofsarscov2comparisonoffourrealtimepcrassays AT leesukyung standardm10sarscov2assayforrapiddetectionofsarscov2comparisonoffourrealtimepcrassays AT choeunjung standardm10sarscov2assayforrapiddetectionofsarscov2comparisonoffourrealtimepcrassays AT hyunjungwon standardm10sarscov2assayforrapiddetectionofsarscov2comparisonoffourrealtimepcrassays AT parkminjeong standardm10sarscov2assayforrapiddetectionofsarscov2comparisonoffourrealtimepcrassays AT songwonkeun standardm10sarscov2assayforrapiddetectionofsarscov2comparisonoffourrealtimepcrassays AT kimhyunsoo standardm10sarscov2assayforrapiddetectionofsarscov2comparisonoffourrealtimepcrassays |