Cargando…

Heat Transfer Analysis between R744 and HFOs inside Plate Heat Exchangers

Plate heat exchangers (PHE) are used for a wide range of applications, thus utilizing new and unique heat sources is of crucial importance. R744 has a low critical temperature, which makes its thermophysical properties variation smoother than other supercritical fluids. As a result, it can be used a...

Descripción completa

Detalles Bibliográficos
Autores principales: Elbarghthi, Anas F. A., Hdaib, Mohammad Yousef, Dvořák, Václav
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9407058/
https://www.ncbi.nlm.nih.gov/pubmed/36010814
http://dx.doi.org/10.3390/e24081150
_version_ 1784774271731499008
author Elbarghthi, Anas F. A.
Hdaib, Mohammad Yousef
Dvořák, Václav
author_facet Elbarghthi, Anas F. A.
Hdaib, Mohammad Yousef
Dvořák, Václav
author_sort Elbarghthi, Anas F. A.
collection PubMed
description Plate heat exchangers (PHE) are used for a wide range of applications, thus utilizing new and unique heat sources is of crucial importance. R744 has a low critical temperature, which makes its thermophysical properties variation smoother than other supercritical fluids. As a result, it can be used as a reliable hot stream for PHE, particularly at high temperatures. The local design approach was constructed via MATLAB integrated with the NIST database for real gases. Recently produced HFOs (R1234yf, R1234ze(E), R1234ze(Z), and R1233zd(E)) were utilized as cold fluids flowing through three phases: Liquid-phase, two-phase, and gas-phase. A two-step study was performed to examine the following parameters: Heat transfer coefficients, pressure drop, and effectiveness. In the first step, these parameters were analyzed with a variable number of plates to determine a suitable number for the next step. Then, the effects of hot stream pressure and cold stream superheating difference were investigated with variable cold channel mass fluxes. For the first step, the results showed insignificant differences in the investigated parameters for the number of plates higher than 40. Meanwhile, the second step showed that increasing the hot stream pressure from 10 to 12 MPa enhanced the two-phase convection coefficients by 17%, 23%, 75%, and 50% for R1234yf, R1234ze(E), R1234ze(Z), and R1233zd(E), respectively. In contrast, increasing the cold stream superheating temperature difference from 5 K to 20 reduced the two-phase convection coefficients by 14%, 16%, 53%, and 26% for R1234yf, R1234ze(E), R1234ze(Z), and R1233zd(E), respectively. Therefore, the R744 is suitable for PHE as a driving heat source, particularly at higher R744 inlet pressure and low cold stream superheating difference.
format Online
Article
Text
id pubmed-9407058
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-94070582022-08-26 Heat Transfer Analysis between R744 and HFOs inside Plate Heat Exchangers Elbarghthi, Anas F. A. Hdaib, Mohammad Yousef Dvořák, Václav Entropy (Basel) Article Plate heat exchangers (PHE) are used for a wide range of applications, thus utilizing new and unique heat sources is of crucial importance. R744 has a low critical temperature, which makes its thermophysical properties variation smoother than other supercritical fluids. As a result, it can be used as a reliable hot stream for PHE, particularly at high temperatures. The local design approach was constructed via MATLAB integrated with the NIST database for real gases. Recently produced HFOs (R1234yf, R1234ze(E), R1234ze(Z), and R1233zd(E)) were utilized as cold fluids flowing through three phases: Liquid-phase, two-phase, and gas-phase. A two-step study was performed to examine the following parameters: Heat transfer coefficients, pressure drop, and effectiveness. In the first step, these parameters were analyzed with a variable number of plates to determine a suitable number for the next step. Then, the effects of hot stream pressure and cold stream superheating difference were investigated with variable cold channel mass fluxes. For the first step, the results showed insignificant differences in the investigated parameters for the number of plates higher than 40. Meanwhile, the second step showed that increasing the hot stream pressure from 10 to 12 MPa enhanced the two-phase convection coefficients by 17%, 23%, 75%, and 50% for R1234yf, R1234ze(E), R1234ze(Z), and R1233zd(E), respectively. In contrast, increasing the cold stream superheating temperature difference from 5 K to 20 reduced the two-phase convection coefficients by 14%, 16%, 53%, and 26% for R1234yf, R1234ze(E), R1234ze(Z), and R1233zd(E), respectively. Therefore, the R744 is suitable for PHE as a driving heat source, particularly at higher R744 inlet pressure and low cold stream superheating difference. MDPI 2022-08-18 /pmc/articles/PMC9407058/ /pubmed/36010814 http://dx.doi.org/10.3390/e24081150 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Elbarghthi, Anas F. A.
Hdaib, Mohammad Yousef
Dvořák, Václav
Heat Transfer Analysis between R744 and HFOs inside Plate Heat Exchangers
title Heat Transfer Analysis between R744 and HFOs inside Plate Heat Exchangers
title_full Heat Transfer Analysis between R744 and HFOs inside Plate Heat Exchangers
title_fullStr Heat Transfer Analysis between R744 and HFOs inside Plate Heat Exchangers
title_full_unstemmed Heat Transfer Analysis between R744 and HFOs inside Plate Heat Exchangers
title_short Heat Transfer Analysis between R744 and HFOs inside Plate Heat Exchangers
title_sort heat transfer analysis between r744 and hfos inside plate heat exchangers
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9407058/
https://www.ncbi.nlm.nih.gov/pubmed/36010814
http://dx.doi.org/10.3390/e24081150
work_keys_str_mv AT elbarghthianasfa heattransferanalysisbetweenr744andhfosinsideplateheatexchangers
AT hdaibmohammadyousef heattransferanalysisbetweenr744andhfosinsideplateheatexchangers
AT dvorakvaclav heattransferanalysisbetweenr744andhfosinsideplateheatexchangers