Cargando…
Energy Analysis of Precooling Air Compressor System
Energy saving is one of the main technique routes for net zero carbon emissions. Air compressor systems take up a large part of energy consumption in the industrial field. A pre-cooling air compressor system was proposed for energy saving by cooling the air before it flows in a compressor. The energ...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9407189/ https://www.ncbi.nlm.nih.gov/pubmed/36010699 http://dx.doi.org/10.3390/e24081035 |
Sumario: | Energy saving is one of the main technique routes for net zero carbon emissions. Air compressor systems take up a large part of energy consumption in the industrial field. A pre-cooling air compressor system was proposed for energy saving by cooling the air before it flows in a compressor. The energy efficiency of the proposed system was analyzed. As additional energy consumption is required for air cooling, the feasibility of the pre-cooling method for energy saving was analyzed. As the efficiency of the pre-cooling air compressor system is mainly influenced by the environment temperature and humidity, applicability of the system in different regions and at different seasons was discussed. A pilot project was performed to verify the technical feasibility and economics of the proposed system. When the precooling temperature of the pilot system was set to 2 °C, the annual pneumatic-electrical ratio of the system can be increased by approximately 2% in several regions of China. This paper shows the pre-cooling air compressor system is feasible for energy saving. |
---|