Cargando…

A Contemporary Approach to Non-Invasive 3D Determination of Individual Masticatory Muscle Forces: A Proof of Concept

Over the past decade, the demand for three-dimensional (3D) patient-specific (PS) modelling and simulations has increased considerably; they are now widely available and generally accepted as part of patient care. However, the patient specificity of current PS designs is often limited to this patien...

Descripción completa

Detalles Bibliográficos
Autores principales: Merema, Bram B. J., Sieswerda, Jelbrich J., Spijkervet, Frederik K. L., Kraeima, Joep, Witjes, Max J. H.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9409695/
https://www.ncbi.nlm.nih.gov/pubmed/36013222
http://dx.doi.org/10.3390/jpm12081273
_version_ 1784774914200305664
author Merema, Bram B. J.
Sieswerda, Jelbrich J.
Spijkervet, Frederik K. L.
Kraeima, Joep
Witjes, Max J. H.
author_facet Merema, Bram B. J.
Sieswerda, Jelbrich J.
Spijkervet, Frederik K. L.
Kraeima, Joep
Witjes, Max J. H.
author_sort Merema, Bram B. J.
collection PubMed
description Over the past decade, the demand for three-dimensional (3D) patient-specific (PS) modelling and simulations has increased considerably; they are now widely available and generally accepted as part of patient care. However, the patient specificity of current PS designs is often limited to this patient-matched fit and lacks individual mechanical aspects, or parameters, that conform to the specific patient’s needs in terms of biomechanical acceptance. Most biomechanical models of the mandible, e.g., finite element analyses (FEA), often used to design reconstructive implants or total joint replacement devices for the temporomandibular joint (TMJ), make use of a literature-based (mean) simplified muscular model of the masticatory muscles. A muscle’s cross-section seems proportionally related to its maximum contractile force and can be multiplied by an intrinsic strength constant, which previously has been calculated to be a constant of 37 [N/cm(2)]. Here, we propose a contemporary method to determine the patient-specific intrinsic strength value of the elevator mouth-closing muscles. The hypothesis is that patient-specific individual mandible elevator muscle forces can be approximated in a non-invasive manner. MRI muscle delineation was combined with bite force measurements and 3D-FEA to determine PS intrinsic strength values. The subject-specific intrinsic strength values were 40.6 [N/cm(2)] and 25.6 [N/cm(2)] for the 29- and 56-year-old subjects, respectively. Despite using a small cohort in this proof of concept study, we show that there is great variation between our subjects’ individual muscular intrinsic strength. This variation, together with the difference between our individual results and those presented in the literature, emphasises the value of our patient-specific muscle modelling and intrinsic strength determination protocol to ensure accurate biomechanical analyses and simulations. Furthermore, it suggests that average muscular models may only be sufficiently accurate for biomechanical analyses at a macro-scale level. A future larger cohort study will put the patient-specific intrinsic strength values in perspective.
format Online
Article
Text
id pubmed-9409695
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-94096952022-08-26 A Contemporary Approach to Non-Invasive 3D Determination of Individual Masticatory Muscle Forces: A Proof of Concept Merema, Bram B. J. Sieswerda, Jelbrich J. Spijkervet, Frederik K. L. Kraeima, Joep Witjes, Max J. H. J Pers Med Article Over the past decade, the demand for three-dimensional (3D) patient-specific (PS) modelling and simulations has increased considerably; they are now widely available and generally accepted as part of patient care. However, the patient specificity of current PS designs is often limited to this patient-matched fit and lacks individual mechanical aspects, or parameters, that conform to the specific patient’s needs in terms of biomechanical acceptance. Most biomechanical models of the mandible, e.g., finite element analyses (FEA), often used to design reconstructive implants or total joint replacement devices for the temporomandibular joint (TMJ), make use of a literature-based (mean) simplified muscular model of the masticatory muscles. A muscle’s cross-section seems proportionally related to its maximum contractile force and can be multiplied by an intrinsic strength constant, which previously has been calculated to be a constant of 37 [N/cm(2)]. Here, we propose a contemporary method to determine the patient-specific intrinsic strength value of the elevator mouth-closing muscles. The hypothesis is that patient-specific individual mandible elevator muscle forces can be approximated in a non-invasive manner. MRI muscle delineation was combined with bite force measurements and 3D-FEA to determine PS intrinsic strength values. The subject-specific intrinsic strength values were 40.6 [N/cm(2)] and 25.6 [N/cm(2)] for the 29- and 56-year-old subjects, respectively. Despite using a small cohort in this proof of concept study, we show that there is great variation between our subjects’ individual muscular intrinsic strength. This variation, together with the difference between our individual results and those presented in the literature, emphasises the value of our patient-specific muscle modelling and intrinsic strength determination protocol to ensure accurate biomechanical analyses and simulations. Furthermore, it suggests that average muscular models may only be sufficiently accurate for biomechanical analyses at a macro-scale level. A future larger cohort study will put the patient-specific intrinsic strength values in perspective. MDPI 2022-08-02 /pmc/articles/PMC9409695/ /pubmed/36013222 http://dx.doi.org/10.3390/jpm12081273 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Merema, Bram B. J.
Sieswerda, Jelbrich J.
Spijkervet, Frederik K. L.
Kraeima, Joep
Witjes, Max J. H.
A Contemporary Approach to Non-Invasive 3D Determination of Individual Masticatory Muscle Forces: A Proof of Concept
title A Contemporary Approach to Non-Invasive 3D Determination of Individual Masticatory Muscle Forces: A Proof of Concept
title_full A Contemporary Approach to Non-Invasive 3D Determination of Individual Masticatory Muscle Forces: A Proof of Concept
title_fullStr A Contemporary Approach to Non-Invasive 3D Determination of Individual Masticatory Muscle Forces: A Proof of Concept
title_full_unstemmed A Contemporary Approach to Non-Invasive 3D Determination of Individual Masticatory Muscle Forces: A Proof of Concept
title_short A Contemporary Approach to Non-Invasive 3D Determination of Individual Masticatory Muscle Forces: A Proof of Concept
title_sort contemporary approach to non-invasive 3d determination of individual masticatory muscle forces: a proof of concept
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9409695/
https://www.ncbi.nlm.nih.gov/pubmed/36013222
http://dx.doi.org/10.3390/jpm12081273
work_keys_str_mv AT meremabrambj acontemporaryapproachtononinvasive3ddeterminationofindividualmasticatorymuscleforcesaproofofconcept
AT sieswerdajelbrichj acontemporaryapproachtononinvasive3ddeterminationofindividualmasticatorymuscleforcesaproofofconcept
AT spijkervetfrederikkl acontemporaryapproachtononinvasive3ddeterminationofindividualmasticatorymuscleforcesaproofofconcept
AT kraeimajoep acontemporaryapproachtononinvasive3ddeterminationofindividualmasticatorymuscleforcesaproofofconcept
AT witjesmaxjh acontemporaryapproachtononinvasive3ddeterminationofindividualmasticatorymuscleforcesaproofofconcept
AT meremabrambj contemporaryapproachtononinvasive3ddeterminationofindividualmasticatorymuscleforcesaproofofconcept
AT sieswerdajelbrichj contemporaryapproachtononinvasive3ddeterminationofindividualmasticatorymuscleforcesaproofofconcept
AT spijkervetfrederikkl contemporaryapproachtononinvasive3ddeterminationofindividualmasticatorymuscleforcesaproofofconcept
AT kraeimajoep contemporaryapproachtononinvasive3ddeterminationofindividualmasticatorymuscleforcesaproofofconcept
AT witjesmaxjh contemporaryapproachtononinvasive3ddeterminationofindividualmasticatorymuscleforcesaproofofconcept