Cargando…

Forgivingness of an Anteromedially Positioned Small Locked Plate for High Tibial Osteotomy in Case of Overcorrection and Lateral Hinge Fracture

High tibial osteotomy (HTO) represents a sensible treatment option for patients with moderate unicondylar osteoarthritis of the knee and extraarticular malalignment. The possibility of a continuously variable correction setting and a surgical approach low in complications has meant that the medial o...

Descripción completa

Detalles Bibliográficos
Autores principales: Böhle, Sabrina, Bischoff, Lars, Ehrenmann, Kristin, Layher, Frank, Sander, Klaus, Matziolis, Georg, Pietsch, Stefan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9409794/
https://www.ncbi.nlm.nih.gov/pubmed/36013443
http://dx.doi.org/10.3390/life12081265
_version_ 1784774938053312512
author Böhle, Sabrina
Bischoff, Lars
Ehrenmann, Kristin
Layher, Frank
Sander, Klaus
Matziolis, Georg
Pietsch, Stefan
author_facet Böhle, Sabrina
Bischoff, Lars
Ehrenmann, Kristin
Layher, Frank
Sander, Klaus
Matziolis, Georg
Pietsch, Stefan
author_sort Böhle, Sabrina
collection PubMed
description High tibial osteotomy (HTO) represents a sensible treatment option for patients with moderate unicondylar osteoarthritis of the knee and extraarticular malalignment. The possibility of a continuously variable correction setting and a surgical approach low in complications has meant that the medial opening osteotomy has prevailed over the past decades. The objective of the present study was to determine whether anteromedially positioned small plates are nevertheless forgiving under biomechanically unfavourable conditions (overcorrection and lateral hinge fracture). In this study, a simulated HTO was performed on composite tibiae with a 10-mm wedge and fixed-angle anteromedial osteosynthesis with a small implant. Force was applied axially in a neutral mechanical axis, a slight and a marked overcorrection into valgus, with and without a lateral hinge fracture in each case. At the same time, a physiological gait with a dual-peak force profile and a peak load of 2.4 kN was simulated. Interfragmentary motion and rigidity were determined. The rigidity of the osteosynthesis increased over the cycles investigated. A slight overcorrection into valgus led to the lowest interfragmentary motion, compared with pronounced valgisation and neutral alignment. A lateral hinge fracture led to a significant decrease in rigidity and increase in interfragmentary motion. However, in no case was the limit of 1 mm interfragmentary motion critical for osteotomy healing exceeded. The degree of correction of the leg axis, and the presence of a lateral hinge fracture, have an influence on rigidity and interfragmentary motion. From a mechanically neutral axis ranging up to pronounced overcorrection, the implant investigated offers sufficient stability to allow healing of the osteotomy, even if a lateral hinge fracture is present.
format Online
Article
Text
id pubmed-9409794
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-94097942022-08-26 Forgivingness of an Anteromedially Positioned Small Locked Plate for High Tibial Osteotomy in Case of Overcorrection and Lateral Hinge Fracture Böhle, Sabrina Bischoff, Lars Ehrenmann, Kristin Layher, Frank Sander, Klaus Matziolis, Georg Pietsch, Stefan Life (Basel) Article High tibial osteotomy (HTO) represents a sensible treatment option for patients with moderate unicondylar osteoarthritis of the knee and extraarticular malalignment. The possibility of a continuously variable correction setting and a surgical approach low in complications has meant that the medial opening osteotomy has prevailed over the past decades. The objective of the present study was to determine whether anteromedially positioned small plates are nevertheless forgiving under biomechanically unfavourable conditions (overcorrection and lateral hinge fracture). In this study, a simulated HTO was performed on composite tibiae with a 10-mm wedge and fixed-angle anteromedial osteosynthesis with a small implant. Force was applied axially in a neutral mechanical axis, a slight and a marked overcorrection into valgus, with and without a lateral hinge fracture in each case. At the same time, a physiological gait with a dual-peak force profile and a peak load of 2.4 kN was simulated. Interfragmentary motion and rigidity were determined. The rigidity of the osteosynthesis increased over the cycles investigated. A slight overcorrection into valgus led to the lowest interfragmentary motion, compared with pronounced valgisation and neutral alignment. A lateral hinge fracture led to a significant decrease in rigidity and increase in interfragmentary motion. However, in no case was the limit of 1 mm interfragmentary motion critical for osteotomy healing exceeded. The degree of correction of the leg axis, and the presence of a lateral hinge fracture, have an influence on rigidity and interfragmentary motion. From a mechanically neutral axis ranging up to pronounced overcorrection, the implant investigated offers sufficient stability to allow healing of the osteotomy, even if a lateral hinge fracture is present. MDPI 2022-08-19 /pmc/articles/PMC9409794/ /pubmed/36013443 http://dx.doi.org/10.3390/life12081265 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Böhle, Sabrina
Bischoff, Lars
Ehrenmann, Kristin
Layher, Frank
Sander, Klaus
Matziolis, Georg
Pietsch, Stefan
Forgivingness of an Anteromedially Positioned Small Locked Plate for High Tibial Osteotomy in Case of Overcorrection and Lateral Hinge Fracture
title Forgivingness of an Anteromedially Positioned Small Locked Plate for High Tibial Osteotomy in Case of Overcorrection and Lateral Hinge Fracture
title_full Forgivingness of an Anteromedially Positioned Small Locked Plate for High Tibial Osteotomy in Case of Overcorrection and Lateral Hinge Fracture
title_fullStr Forgivingness of an Anteromedially Positioned Small Locked Plate for High Tibial Osteotomy in Case of Overcorrection and Lateral Hinge Fracture
title_full_unstemmed Forgivingness of an Anteromedially Positioned Small Locked Plate for High Tibial Osteotomy in Case of Overcorrection and Lateral Hinge Fracture
title_short Forgivingness of an Anteromedially Positioned Small Locked Plate for High Tibial Osteotomy in Case of Overcorrection and Lateral Hinge Fracture
title_sort forgivingness of an anteromedially positioned small locked plate for high tibial osteotomy in case of overcorrection and lateral hinge fracture
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9409794/
https://www.ncbi.nlm.nih.gov/pubmed/36013443
http://dx.doi.org/10.3390/life12081265
work_keys_str_mv AT bohlesabrina forgivingnessofananteromediallypositionedsmalllockedplateforhightibialosteotomyincaseofovercorrectionandlateralhingefracture
AT bischofflars forgivingnessofananteromediallypositionedsmalllockedplateforhightibialosteotomyincaseofovercorrectionandlateralhingefracture
AT ehrenmannkristin forgivingnessofananteromediallypositionedsmalllockedplateforhightibialosteotomyincaseofovercorrectionandlateralhingefracture
AT layherfrank forgivingnessofananteromediallypositionedsmalllockedplateforhightibialosteotomyincaseofovercorrectionandlateralhingefracture
AT sanderklaus forgivingnessofananteromediallypositionedsmalllockedplateforhightibialosteotomyincaseofovercorrectionandlateralhingefracture
AT matziolisgeorg forgivingnessofananteromediallypositionedsmalllockedplateforhightibialosteotomyincaseofovercorrectionandlateralhingefracture
AT pietschstefan forgivingnessofananteromediallypositionedsmalllockedplateforhightibialosteotomyincaseofovercorrectionandlateralhingefracture