Myocardial T2* Imaging at 3T and 1.5T: A Pilot Study with Phantom and Normal Myocardium
Background: Myocardial T2* mapping at 1.5T remains the gold standard, but the use of 3T scanners is increasing. We aimed to determine the conversion equations in different scanners with clinically available, vendor-provided T2* mapping sequences using a phantom and evaluated the feasibility of the p...
Autores principales: | Chang, Suyon, Park, Jinho, Yang, Young-Joong, Beck, Kyongmin Sarah, Kim, Pan Ki, Choi, Byoung Wook, Jung, Jung Im |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9410052/ https://www.ncbi.nlm.nih.gov/pubmed/36005435 http://dx.doi.org/10.3390/jcdd9080271 |
Ejemplares similares
-
Phantom-based correction for standardization of myocardial native T1 and extracellular volume fraction in healthy subjects at 3-Tesla cardiac magnetic resonance imaging
por: Suh, Young Joo, et al.
Publicado: (2022) -
Radiological and pathological analysis of the galaxy sign in patients with pulmonary mucosa‐associated lymphoid tissue (MALT) lymphoma
por: Song, Yeongran, et al.
Publicado: (2023) -
Migratory Pneumonia in Prolonged SARS-CoV-2 Infection in Patients Treated With B-cell Depletion Therapies for B-cell Lymphoma
por: Lee, Jongmin, et al.
Publicado: (2023) -
Myocardial T1 and T2 Mapping: Techniques and Clinical Applications
por: Kim, Pan Ki, et al.
Publicado: (2017) -
Automated Measurement of Native T1 and Extracellular Volume Fraction in Cardiac Magnetic Resonance Imaging Using a Commercially Available Deep Learning Algorithm
por: Chang, Suyon, et al.
Publicado: (2022)