Cargando…

Speckled Tracking of Pleura—A Novel Tool for Lung Ultrasound; Distinguishing COVID-19 from Acute Heart Failure

For the acutely dyspneic patient, discerning bedside between acute decompensated heart failure (ADHF) and COVID-19 is crucial. A lung ultrasound (LUS) is sensitive for detecting these conditions, but not in distinguishing between them; both have bilateral B-lines. The Blue protocol uses pleural slid...

Descripción completa

Detalles Bibliográficos
Autores principales: Tzadok, Batsheva, Blumberg, Yair, Shubert, Moti, Halabi, Majdi, Tal-Or, Eran, Bachner-Hinenzon, Noa, Carasso, Shemy
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9410136/
https://www.ncbi.nlm.nih.gov/pubmed/36013081
http://dx.doi.org/10.3390/jcm11164846
_version_ 1784775021094240256
author Tzadok, Batsheva
Blumberg, Yair
Shubert, Moti
Halabi, Majdi
Tal-Or, Eran
Bachner-Hinenzon, Noa
Carasso, Shemy
author_facet Tzadok, Batsheva
Blumberg, Yair
Shubert, Moti
Halabi, Majdi
Tal-Or, Eran
Bachner-Hinenzon, Noa
Carasso, Shemy
author_sort Tzadok, Batsheva
collection PubMed
description For the acutely dyspneic patient, discerning bedside between acute decompensated heart failure (ADHF) and COVID-19 is crucial. A lung ultrasound (LUS) is sensitive for detecting these conditions, but not in distinguishing between them; both have bilateral B-lines. The Blue protocol uses pleural sliding to differentiate decreased pneumonia; however, this is not the case in ADHF. Nonetheless, this pleural sliding has never been quantified. Speckled tracking is a technology utilized in the echocardiography field that quantifies the motion of tissues by examining the movement of ultrasound speckles. We conducted a retrospective study of LUS performed in emergency room patients during the COVID-19 pandemic. Speckled tracking of the pleura by applying software to the B-mode of pleura was compared between COVID-19 patients, ADHF patients, and patients with no respiratory complaints. A significant difference was found between the patient groups on speckled tracking both in respect of displacement and velocity. ADHF had the highest displacement, followed by COVID-19, and then non-respiratory patients: 1.63 ± 1.89, 0.59 ± 0.71, and 0.24 ± 0.45, respectively (p < 0.01). A similar trend was seen in velocity with ADHF having the highest velocity 0.34 ± 0.37, followed by COVID-19 0.14 ± 0.71, and non-respiratory patients 0.02 ± 0.09 (p <0.01). Speckled tracking of the pleura is a potential tool for discerning between different causes of dyspnea.
format Online
Article
Text
id pubmed-9410136
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-94101362022-08-26 Speckled Tracking of Pleura—A Novel Tool for Lung Ultrasound; Distinguishing COVID-19 from Acute Heart Failure Tzadok, Batsheva Blumberg, Yair Shubert, Moti Halabi, Majdi Tal-Or, Eran Bachner-Hinenzon, Noa Carasso, Shemy J Clin Med Communication For the acutely dyspneic patient, discerning bedside between acute decompensated heart failure (ADHF) and COVID-19 is crucial. A lung ultrasound (LUS) is sensitive for detecting these conditions, but not in distinguishing between them; both have bilateral B-lines. The Blue protocol uses pleural sliding to differentiate decreased pneumonia; however, this is not the case in ADHF. Nonetheless, this pleural sliding has never been quantified. Speckled tracking is a technology utilized in the echocardiography field that quantifies the motion of tissues by examining the movement of ultrasound speckles. We conducted a retrospective study of LUS performed in emergency room patients during the COVID-19 pandemic. Speckled tracking of the pleura by applying software to the B-mode of pleura was compared between COVID-19 patients, ADHF patients, and patients with no respiratory complaints. A significant difference was found between the patient groups on speckled tracking both in respect of displacement and velocity. ADHF had the highest displacement, followed by COVID-19, and then non-respiratory patients: 1.63 ± 1.89, 0.59 ± 0.71, and 0.24 ± 0.45, respectively (p < 0.01). A similar trend was seen in velocity with ADHF having the highest velocity 0.34 ± 0.37, followed by COVID-19 0.14 ± 0.71, and non-respiratory patients 0.02 ± 0.09 (p <0.01). Speckled tracking of the pleura is a potential tool for discerning between different causes of dyspnea. MDPI 2022-08-18 /pmc/articles/PMC9410136/ /pubmed/36013081 http://dx.doi.org/10.3390/jcm11164846 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Communication
Tzadok, Batsheva
Blumberg, Yair
Shubert, Moti
Halabi, Majdi
Tal-Or, Eran
Bachner-Hinenzon, Noa
Carasso, Shemy
Speckled Tracking of Pleura—A Novel Tool for Lung Ultrasound; Distinguishing COVID-19 from Acute Heart Failure
title Speckled Tracking of Pleura—A Novel Tool for Lung Ultrasound; Distinguishing COVID-19 from Acute Heart Failure
title_full Speckled Tracking of Pleura—A Novel Tool for Lung Ultrasound; Distinguishing COVID-19 from Acute Heart Failure
title_fullStr Speckled Tracking of Pleura—A Novel Tool for Lung Ultrasound; Distinguishing COVID-19 from Acute Heart Failure
title_full_unstemmed Speckled Tracking of Pleura—A Novel Tool for Lung Ultrasound; Distinguishing COVID-19 from Acute Heart Failure
title_short Speckled Tracking of Pleura—A Novel Tool for Lung Ultrasound; Distinguishing COVID-19 from Acute Heart Failure
title_sort speckled tracking of pleura—a novel tool for lung ultrasound; distinguishing covid-19 from acute heart failure
topic Communication
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9410136/
https://www.ncbi.nlm.nih.gov/pubmed/36013081
http://dx.doi.org/10.3390/jcm11164846
work_keys_str_mv AT tzadokbatsheva speckledtrackingofpleuraanoveltoolforlungultrasounddistinguishingcovid19fromacuteheartfailure
AT blumbergyair speckledtrackingofpleuraanoveltoolforlungultrasounddistinguishingcovid19fromacuteheartfailure
AT shubertmoti speckledtrackingofpleuraanoveltoolforlungultrasounddistinguishingcovid19fromacuteheartfailure
AT halabimajdi speckledtrackingofpleuraanoveltoolforlungultrasounddistinguishingcovid19fromacuteheartfailure
AT taloreran speckledtrackingofpleuraanoveltoolforlungultrasounddistinguishingcovid19fromacuteheartfailure
AT bachnerhinenzonnoa speckledtrackingofpleuraanoveltoolforlungultrasounddistinguishingcovid19fromacuteheartfailure
AT carassoshemy speckledtrackingofpleuraanoveltoolforlungultrasounddistinguishingcovid19fromacuteheartfailure