Cargando…

Image Quality Comparison between Digital Breast Tomosynthesis Images and 2D Mammographic Images Using the CDMAM Test Object

To evaluate the image quality (IQ) of synthesized two-dimensional (s2D) and tomographic layer (TL) mammographic images in comparison to the 2D digital mammographic images produced with a new digital breast tomosynthesis (DBT) system. Methods: The CDMAM test object was used for IQ evaluation of actua...

Descripción completa

Detalles Bibliográficos
Autores principales: Tsalafoutas, Ioannis A., Epistatou, Angeliki C., Delibasis, Konstantinos K.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9410151/
https://www.ncbi.nlm.nih.gov/pubmed/36005466
http://dx.doi.org/10.3390/jimaging8080223
_version_ 1784775024835559424
author Tsalafoutas, Ioannis A.
Epistatou, Angeliki C.
Delibasis, Konstantinos K.
author_facet Tsalafoutas, Ioannis A.
Epistatou, Angeliki C.
Delibasis, Konstantinos K.
author_sort Tsalafoutas, Ioannis A.
collection PubMed
description To evaluate the image quality (IQ) of synthesized two-dimensional (s2D) and tomographic layer (TL) mammographic images in comparison to the 2D digital mammographic images produced with a new digital breast tomosynthesis (DBT) system. Methods: The CDMAM test object was used for IQ evaluation of actual 2D images, s2D and TL images, acquired using all available acquisition modes. Evaluation was performed automatically using the commercial software that accompanied CDMAM. Results: The IQ scores of the TLs with the in-focus CDMAM were comparable, although usually inferior to those of 2D images acquired with the same acquisition mode, and better than the respective s2D images. The IQ results of TLs satisfied the EUREF limits applicable to 2D images, whereas for s2D images this was not the case. The use of high-dose mode (H-mode), instead of normal-dose mode (N-mode), increased the image quality of both TL and s2D images, especially when the standard mode (ST) was used. Although the high-resolution (HR) mode produced TL images of similar or better image quality compared to ST mode, HR s2D images were clearly inferior to ST s2D images. Conclusions: s2D images present inferior image quality compared to 2D and TL images. The HR mode produces TL images and s2D images with half the pixel size and requires a 25% increase in average glandular dose (AGD). Despite that, IQ evaluation results with CDMAM are in favor of HR resolution mode only for TL images and mainly for smaller-sized details.
format Online
Article
Text
id pubmed-9410151
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-94101512022-08-26 Image Quality Comparison between Digital Breast Tomosynthesis Images and 2D Mammographic Images Using the CDMAM Test Object Tsalafoutas, Ioannis A. Epistatou, Angeliki C. Delibasis, Konstantinos K. J Imaging Article To evaluate the image quality (IQ) of synthesized two-dimensional (s2D) and tomographic layer (TL) mammographic images in comparison to the 2D digital mammographic images produced with a new digital breast tomosynthesis (DBT) system. Methods: The CDMAM test object was used for IQ evaluation of actual 2D images, s2D and TL images, acquired using all available acquisition modes. Evaluation was performed automatically using the commercial software that accompanied CDMAM. Results: The IQ scores of the TLs with the in-focus CDMAM were comparable, although usually inferior to those of 2D images acquired with the same acquisition mode, and better than the respective s2D images. The IQ results of TLs satisfied the EUREF limits applicable to 2D images, whereas for s2D images this was not the case. The use of high-dose mode (H-mode), instead of normal-dose mode (N-mode), increased the image quality of both TL and s2D images, especially when the standard mode (ST) was used. Although the high-resolution (HR) mode produced TL images of similar or better image quality compared to ST mode, HR s2D images were clearly inferior to ST s2D images. Conclusions: s2D images present inferior image quality compared to 2D and TL images. The HR mode produces TL images and s2D images with half the pixel size and requires a 25% increase in average glandular dose (AGD). Despite that, IQ evaluation results with CDMAM are in favor of HR resolution mode only for TL images and mainly for smaller-sized details. MDPI 2022-08-21 /pmc/articles/PMC9410151/ /pubmed/36005466 http://dx.doi.org/10.3390/jimaging8080223 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Tsalafoutas, Ioannis A.
Epistatou, Angeliki C.
Delibasis, Konstantinos K.
Image Quality Comparison between Digital Breast Tomosynthesis Images and 2D Mammographic Images Using the CDMAM Test Object
title Image Quality Comparison between Digital Breast Tomosynthesis Images and 2D Mammographic Images Using the CDMAM Test Object
title_full Image Quality Comparison between Digital Breast Tomosynthesis Images and 2D Mammographic Images Using the CDMAM Test Object
title_fullStr Image Quality Comparison between Digital Breast Tomosynthesis Images and 2D Mammographic Images Using the CDMAM Test Object
title_full_unstemmed Image Quality Comparison between Digital Breast Tomosynthesis Images and 2D Mammographic Images Using the CDMAM Test Object
title_short Image Quality Comparison between Digital Breast Tomosynthesis Images and 2D Mammographic Images Using the CDMAM Test Object
title_sort image quality comparison between digital breast tomosynthesis images and 2d mammographic images using the cdmam test object
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9410151/
https://www.ncbi.nlm.nih.gov/pubmed/36005466
http://dx.doi.org/10.3390/jimaging8080223
work_keys_str_mv AT tsalafoutasioannisa imagequalitycomparisonbetweendigitalbreasttomosynthesisimagesand2dmammographicimagesusingthecdmamtestobject
AT epistatouangelikic imagequalitycomparisonbetweendigitalbreasttomosynthesisimagesand2dmammographicimagesusingthecdmamtestobject
AT delibasiskonstantinosk imagequalitycomparisonbetweendigitalbreasttomosynthesisimagesand2dmammographicimagesusingthecdmamtestobject