Cargando…

Two Independent Capsules Surrounding a Single Textured Implant in Ehlers-Danlos Syndrome

Textured breast implants are associated with prolonged inflammation leading to increased risk for complications such as the development of anaplastic large cell lymphoma. The underlying molecular mechanisms that drive increased inflammation toward textured implants (compared with smooth implants) re...

Descripción completa

Detalles Bibliográficos
Autores principales: Padmanabhan, Jagannath, Liu, Farrah C., Sivaraj, Dharshan, Henn, Dominic, Chen, Kellen, Simon, Devorah R., Barrera, Janos A., Gurtner, Geoffrey C.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Lippincott Williams & Wilkins 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9410635/
https://www.ncbi.nlm.nih.gov/pubmed/36032379
http://dx.doi.org/10.1097/GOX.0000000000004470
_version_ 1784775139673505792
author Padmanabhan, Jagannath
Liu, Farrah C.
Sivaraj, Dharshan
Henn, Dominic
Chen, Kellen
Simon, Devorah R.
Barrera, Janos A.
Gurtner, Geoffrey C.
author_facet Padmanabhan, Jagannath
Liu, Farrah C.
Sivaraj, Dharshan
Henn, Dominic
Chen, Kellen
Simon, Devorah R.
Barrera, Janos A.
Gurtner, Geoffrey C.
author_sort Padmanabhan, Jagannath
collection PubMed
description Textured breast implants are associated with prolonged inflammation leading to increased risk for complications such as the development of anaplastic large cell lymphoma. The underlying molecular mechanisms that drive increased inflammation toward textured implants (compared with smooth implants) remain poorly understood. Here, we present the first known case of a patient with Ehlers-Danlos syndrome (EDS) who developed two independent fibrotic capsules around a single textured silicone implant. The patient was found to have one internal capsule tightly adherent to the implant and a second external capsule that was attached to the surrounding tissue. We observed that the internal implant-adherent capsule was composed of a highly aligned and dense collagen network, completely atypical for EDS and indicative of a high mechanical stress environment. In contrast, the external nonadherent capsule, which primarily interacted with the smooth surface of the internal capsule, displayed disorganized collagen fibers with no discernible alignment, classic for EDS. Remarkably, we found that the internal capsule displayed high activation of monocyte chemoattractant protein-1, a mechanoresponsive inflammatory mediator that was not elevated in the disorganized external capsule. Taken together, these findings demonstrate that the tight adhesion between the textured implant surface and the internal capsule creates a high mechanical stress environment, which is responsible for the increased local inflammation observed in the internal capsule. This unique case demonstrates that mechanical stress is able to override genetic defects locally in collagen organization and directly connects the textured surface of implants to prolonged inflammation.
format Online
Article
Text
id pubmed-9410635
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Lippincott Williams & Wilkins
record_format MEDLINE/PubMed
spelling pubmed-94106352022-08-26 Two Independent Capsules Surrounding a Single Textured Implant in Ehlers-Danlos Syndrome Padmanabhan, Jagannath Liu, Farrah C. Sivaraj, Dharshan Henn, Dominic Chen, Kellen Simon, Devorah R. Barrera, Janos A. Gurtner, Geoffrey C. Plast Reconstr Surg Glob Open Breast Textured breast implants are associated with prolonged inflammation leading to increased risk for complications such as the development of anaplastic large cell lymphoma. The underlying molecular mechanisms that drive increased inflammation toward textured implants (compared with smooth implants) remain poorly understood. Here, we present the first known case of a patient with Ehlers-Danlos syndrome (EDS) who developed two independent fibrotic capsules around a single textured silicone implant. The patient was found to have one internal capsule tightly adherent to the implant and a second external capsule that was attached to the surrounding tissue. We observed that the internal implant-adherent capsule was composed of a highly aligned and dense collagen network, completely atypical for EDS and indicative of a high mechanical stress environment. In contrast, the external nonadherent capsule, which primarily interacted with the smooth surface of the internal capsule, displayed disorganized collagen fibers with no discernible alignment, classic for EDS. Remarkably, we found that the internal capsule displayed high activation of monocyte chemoattractant protein-1, a mechanoresponsive inflammatory mediator that was not elevated in the disorganized external capsule. Taken together, these findings demonstrate that the tight adhesion between the textured implant surface and the internal capsule creates a high mechanical stress environment, which is responsible for the increased local inflammation observed in the internal capsule. This unique case demonstrates that mechanical stress is able to override genetic defects locally in collagen organization and directly connects the textured surface of implants to prolonged inflammation. Lippincott Williams & Wilkins 2022-08-25 /pmc/articles/PMC9410635/ /pubmed/36032379 http://dx.doi.org/10.1097/GOX.0000000000004470 Text en Copyright © 2022 The Authors. Published by Wolters Kluwer Health, Inc. on behalf of The American Society of Plastic Surgeons. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND) (https://creativecommons.org/licenses/by-nc-nd/4.0/) , where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal.
spellingShingle Breast
Padmanabhan, Jagannath
Liu, Farrah C.
Sivaraj, Dharshan
Henn, Dominic
Chen, Kellen
Simon, Devorah R.
Barrera, Janos A.
Gurtner, Geoffrey C.
Two Independent Capsules Surrounding a Single Textured Implant in Ehlers-Danlos Syndrome
title Two Independent Capsules Surrounding a Single Textured Implant in Ehlers-Danlos Syndrome
title_full Two Independent Capsules Surrounding a Single Textured Implant in Ehlers-Danlos Syndrome
title_fullStr Two Independent Capsules Surrounding a Single Textured Implant in Ehlers-Danlos Syndrome
title_full_unstemmed Two Independent Capsules Surrounding a Single Textured Implant in Ehlers-Danlos Syndrome
title_short Two Independent Capsules Surrounding a Single Textured Implant in Ehlers-Danlos Syndrome
title_sort two independent capsules surrounding a single textured implant in ehlers-danlos syndrome
topic Breast
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9410635/
https://www.ncbi.nlm.nih.gov/pubmed/36032379
http://dx.doi.org/10.1097/GOX.0000000000004470
work_keys_str_mv AT padmanabhanjagannath twoindependentcapsulessurroundingasingletexturedimplantinehlersdanlossyndrome
AT liufarrahc twoindependentcapsulessurroundingasingletexturedimplantinehlersdanlossyndrome
AT sivarajdharshan twoindependentcapsulessurroundingasingletexturedimplantinehlersdanlossyndrome
AT henndominic twoindependentcapsulessurroundingasingletexturedimplantinehlersdanlossyndrome
AT chenkellen twoindependentcapsulessurroundingasingletexturedimplantinehlersdanlossyndrome
AT simondevorahr twoindependentcapsulessurroundingasingletexturedimplantinehlersdanlossyndrome
AT barrerajanosa twoindependentcapsulessurroundingasingletexturedimplantinehlersdanlossyndrome
AT gurtnergeoffreyc twoindependentcapsulessurroundingasingletexturedimplantinehlersdanlossyndrome