Electrogalvanism in Oral Implantology: A Systematic Review

PURPOSE: The objective of this work is to study galvanic corrosion of different couples of prosthetic and implant alloys through the realization of a systematic review. MATERIALS AND METHODS: An electronic search was performed on Pubmed, Google Scholar, Scopus, ScienceDirect, EbscoHost, and Web of S...

Descripción completa

Detalles Bibliográficos
Autores principales: Amine, Meriem, Merdma, Wiam, El Boussiri, Khalid
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9410998/
https://www.ncbi.nlm.nih.gov/pubmed/36034476
http://dx.doi.org/10.1155/2022/4575416
_version_ 1784775223529177088
author Amine, Meriem
Merdma, Wiam
El Boussiri, Khalid
author_facet Amine, Meriem
Merdma, Wiam
El Boussiri, Khalid
author_sort Amine, Meriem
collection PubMed
description PURPOSE: The objective of this work is to study galvanic corrosion of different couples of prosthetic and implant alloys through the realization of a systematic review. MATERIALS AND METHODS: An electronic search was performed on Pubmed, Google Scholar, Scopus, ScienceDirect, EbscoHost, and Web of Science for published studies related to electrogalvanism in oral implantology. The keywords used were “dental implants” and “galvanic corrosion.” Two independent readers read the scientific articles. RESULTS: From 65 articles initially identified, only 19 articles met the eligibility criteria. The evaluation of the selected articles allowed us to determine the parameters compared, such as the resistance to galvanic corrosion, the influence of fluorine and pH on the electrochemical behavior, and the release of metal ions and their cytotoxicity. Indeed, Ti6Al4V and precious alloys coupled to titanium were found to be the most resistant to galvanic corrosion, followed by cobalt-chromium alloys and nickel-chromium alloys which were least resistant. This resistance decreases with increasing fluorine concentration and with decreasing pH of the environment. Discussion. The implant-prosthetic system's galvanic resistance is influenced by many intrinsic factors: alloy composition and surface condition, as well as extrinsic factors such as pH variations and amount of fluorine. The effects of oral electrogalvanism are essentially the result of two main criteria: effects due to electric currents generated by corrosion and effects due to the release of metal ions by corrosion. CONCLUSION: To avoid this phenomenon, it is wise to follow the proposed recommendations such as the use of the minimum of distinct metals as much as possible, favoring the commercially pure titanium implant of Ti6Al4V, opting for the choice of couples, titanium/titanium, favoring daily mouthwashes of 227 ppm of fluoride, and avoiding fluorinated acid solutions.
format Online
Article
Text
id pubmed-9410998
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-94109982022-08-26 Electrogalvanism in Oral Implantology: A Systematic Review Amine, Meriem Merdma, Wiam El Boussiri, Khalid Int J Dent Review Article PURPOSE: The objective of this work is to study galvanic corrosion of different couples of prosthetic and implant alloys through the realization of a systematic review. MATERIALS AND METHODS: An electronic search was performed on Pubmed, Google Scholar, Scopus, ScienceDirect, EbscoHost, and Web of Science for published studies related to electrogalvanism in oral implantology. The keywords used were “dental implants” and “galvanic corrosion.” Two independent readers read the scientific articles. RESULTS: From 65 articles initially identified, only 19 articles met the eligibility criteria. The evaluation of the selected articles allowed us to determine the parameters compared, such as the resistance to galvanic corrosion, the influence of fluorine and pH on the electrochemical behavior, and the release of metal ions and their cytotoxicity. Indeed, Ti6Al4V and precious alloys coupled to titanium were found to be the most resistant to galvanic corrosion, followed by cobalt-chromium alloys and nickel-chromium alloys which were least resistant. This resistance decreases with increasing fluorine concentration and with decreasing pH of the environment. Discussion. The implant-prosthetic system's galvanic resistance is influenced by many intrinsic factors: alloy composition and surface condition, as well as extrinsic factors such as pH variations and amount of fluorine. The effects of oral electrogalvanism are essentially the result of two main criteria: effects due to electric currents generated by corrosion and effects due to the release of metal ions by corrosion. CONCLUSION: To avoid this phenomenon, it is wise to follow the proposed recommendations such as the use of the minimum of distinct metals as much as possible, favoring the commercially pure titanium implant of Ti6Al4V, opting for the choice of couples, titanium/titanium, favoring daily mouthwashes of 227 ppm of fluoride, and avoiding fluorinated acid solutions. Hindawi 2022-08-05 /pmc/articles/PMC9410998/ /pubmed/36034476 http://dx.doi.org/10.1155/2022/4575416 Text en Copyright © 2022 Meriem Amine et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Review Article
Amine, Meriem
Merdma, Wiam
El Boussiri, Khalid
Electrogalvanism in Oral Implantology: A Systematic Review
title Electrogalvanism in Oral Implantology: A Systematic Review
title_full Electrogalvanism in Oral Implantology: A Systematic Review
title_fullStr Electrogalvanism in Oral Implantology: A Systematic Review
title_full_unstemmed Electrogalvanism in Oral Implantology: A Systematic Review
title_short Electrogalvanism in Oral Implantology: A Systematic Review
title_sort electrogalvanism in oral implantology: a systematic review
topic Review Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9410998/
https://www.ncbi.nlm.nih.gov/pubmed/36034476
http://dx.doi.org/10.1155/2022/4575416
work_keys_str_mv AT aminemeriem electrogalvanisminoralimplantologyasystematicreview
AT merdmawiam electrogalvanisminoralimplantologyasystematicreview
AT elboussirikhalid electrogalvanisminoralimplantologyasystematicreview