Cargando…

Patterns, appropriateness and outcomes of peripherally inserted central catheter use in Brazil: a multicentre study of 12 725 catheters

BACKGROUND: Little is known about peripherally inserted central catheter (PICC) use, appropriateness and device outcomes in Brazil. METHODS: We conducted an observational, prospective, cohort study spanning 16 Brazilian hospitals from October 2018 to August 2020. Patients ≥18 years receiving a PICC...

Descripción completa

Detalles Bibliográficos
Autores principales: Rejane Rabelo-Silva, Eneida, Lourenço, Solange Antonia, Maestri, Rubia Natasha, Candido da Luz, Claudia, Carlos Pupin, Vanderlei, Bauer Cechinel, Raquel, Bordini Ferro, Eduarda, Aurélio Lumertz Saffi, Marco, do Campo Silva, Telma Christina, Martins de Andrade, Larissa, Sales Gomes, Larissa Fernanda, Alves da Gama, Lorena, Marques de Araújo, Mariana, Santo, Fábio Rodrigues Ferreira do Espírito, López Pedraza, Leticia, Hirakata, Vânia Naomi, Santana Soares, Vilma, Sousa Montenegro, Widlani, Rocha Costa de Freitas, Gustavo, Souza de Jesus, Thaís, Chopra, Vineet
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BMJ Publishing Group 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9411873/
https://www.ncbi.nlm.nih.gov/pubmed/35086961
http://dx.doi.org/10.1136/bmjqs-2021-013869
Descripción
Sumario:BACKGROUND: Little is known about peripherally inserted central catheter (PICC) use, appropriateness and device outcomes in Brazil. METHODS: We conducted an observational, prospective, cohort study spanning 16 Brazilian hospitals from October 2018 to August 2020. Patients ≥18 years receiving a PICC were included. PICC placement variables were abstracted from medical records. PICC-related major (deep vein thrombosis (DVT), central line-associated bloodstream infection (CLABSI) and catheter occlusion) and minor complications were collected. Appropriateness was evaluated using the Michigan Appropriateness Guide for Intravenous Catheters (MAGIC). Devices were considered inappropriate if they were in place for <5 days, were multi-lumen, and/or were placed in patients with a creatinine >2.0 mg/dL. PICCs considered appropriate met none of these criteria. Mixed-effects logistic regression models adjusting for patient-level and hospital-level characteristics assessed the association between appropriateness and major complications. RESULTS: Data from 12 725 PICCs were included. Mean patient age was 66.4±19 years and 51.0% were female. The most common indications for PICCs were intravenous antibiotics (81.1%) and difficult access (62.7%). Most PICCs (72.2%) were placed under ultrasound guidance. The prevalence of complications was low: CLABSI (0.9%); catheter-related DVT (1.0%) and reversible occlusion (2.5%). Of the 12 725 devices included, a total of 7935 (62.3%) PICCs were inappropriate according to MAGIC. With respect to individual metrics for appropriateness, 17.0% were placed for <5 days, 60.8% were multi-lumen and 11.3% were in patients with creatinine >2.0 mg/dL. After adjusting for patient and hospital-level characteristics, multi-lumen PICCs considered inappropriate were associated with greater odds of major complications (OR 2.54, 95% CI 1.61 to 4.02). CONCLUSIONS: Use of PICCs in Brazilian hospitals appears to be safe and comparable with North America. However, opportunities to improve appropriateness remain. Future studies examining barriers and facilitators to improving device use in Brazil would be welcomed.