Cargando…

In Vivo Evaluation of PCL Vascular Grafts Implanted in Rat Abdominal Aorta

Electrospun tissue-engineered grafts made of biodegradable materials have become a perspective search field in terms of vascular replacement, and more research is required to describe their in vivo transformation. This study aimed to give a detailed observation of hemodynamic and structural properti...

Descripción completa

Detalles Bibliográficos
Autores principales: Dokuchaeva, Anna A., Mochalova, Aleksandra B., Timchenko, Tatyana P., Podolskaya, Kseniya S., Pashkovskaya, Oxana A., Karpova, Elena V., Ivanov, Ilya A., Filatova, Natalya A., Zhuravleva, Irina Yu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9412484/
https://www.ncbi.nlm.nih.gov/pubmed/36015570
http://dx.doi.org/10.3390/polym14163313
_version_ 1784775505519575040
author Dokuchaeva, Anna A.
Mochalova, Aleksandra B.
Timchenko, Tatyana P.
Podolskaya, Kseniya S.
Pashkovskaya, Oxana A.
Karpova, Elena V.
Ivanov, Ilya A.
Filatova, Natalya A.
Zhuravleva, Irina Yu
author_facet Dokuchaeva, Anna A.
Mochalova, Aleksandra B.
Timchenko, Tatyana P.
Podolskaya, Kseniya S.
Pashkovskaya, Oxana A.
Karpova, Elena V.
Ivanov, Ilya A.
Filatova, Natalya A.
Zhuravleva, Irina Yu
author_sort Dokuchaeva, Anna A.
collection PubMed
description Electrospun tissue-engineered grafts made of biodegradable materials have become a perspective search field in terms of vascular replacement, and more research is required to describe their in vivo transformation. This study aimed to give a detailed observation of hemodynamic and structural properties of electrospun, monolayered poly-ε-caprolactone (PCL) grafts in an in vivo experiment using a rat aorta replacement model at 10, 30, 60 and 90 implantation days. It was shown using ultrasound diagnostic and X-ray tomography that PCL grafts maintain patency throughout the entire follow-up period, without stenosis or thrombosis. Vascular compliance, assessed by the resistance index (RI), remains at the stable level from the 10th to the 90th day. A histological study using hematoxylin-eosin (H&E), von Kossa and Russell–Movat pentachrome staining demonstrated the dynamics of tissue response to the implant. By the 10th day, an endothelial monolayer was forming on the graft luminal surface, followed by the gradual growth and compaction of the neointima up to the 90th day. The intense inflammatory cellular reaction observed on the 10th day in the thickness of the scaffold was changed by the fibroblast and myofibroblast penetration by the 30th day. The cellularity maximum was reached on the 60th day, but by the 90th day the cellularity significantly (p = 0.02) decreased. From the 60th day, in some samples, the calcium phosphate depositions were revealed at the scaffold-neointima interface. Scanning electron microscopy showed that the scaffolds retained their fibrillar structure up to the 90th day. Thus, we have shown that the advantages of PCL scaffolds are excellent endothelialization and good surgical outcome. The disadvantages include their slow biodegradation, ineffective cellularization, and risks for mineralization and intimal hyperplasia.
format Online
Article
Text
id pubmed-9412484
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-94124842022-08-27 In Vivo Evaluation of PCL Vascular Grafts Implanted in Rat Abdominal Aorta Dokuchaeva, Anna A. Mochalova, Aleksandra B. Timchenko, Tatyana P. Podolskaya, Kseniya S. Pashkovskaya, Oxana A. Karpova, Elena V. Ivanov, Ilya A. Filatova, Natalya A. Zhuravleva, Irina Yu Polymers (Basel) Article Electrospun tissue-engineered grafts made of biodegradable materials have become a perspective search field in terms of vascular replacement, and more research is required to describe their in vivo transformation. This study aimed to give a detailed observation of hemodynamic and structural properties of electrospun, monolayered poly-ε-caprolactone (PCL) grafts in an in vivo experiment using a rat aorta replacement model at 10, 30, 60 and 90 implantation days. It was shown using ultrasound diagnostic and X-ray tomography that PCL grafts maintain patency throughout the entire follow-up period, without stenosis or thrombosis. Vascular compliance, assessed by the resistance index (RI), remains at the stable level from the 10th to the 90th day. A histological study using hematoxylin-eosin (H&E), von Kossa and Russell–Movat pentachrome staining demonstrated the dynamics of tissue response to the implant. By the 10th day, an endothelial monolayer was forming on the graft luminal surface, followed by the gradual growth and compaction of the neointima up to the 90th day. The intense inflammatory cellular reaction observed on the 10th day in the thickness of the scaffold was changed by the fibroblast and myofibroblast penetration by the 30th day. The cellularity maximum was reached on the 60th day, but by the 90th day the cellularity significantly (p = 0.02) decreased. From the 60th day, in some samples, the calcium phosphate depositions were revealed at the scaffold-neointima interface. Scanning electron microscopy showed that the scaffolds retained their fibrillar structure up to the 90th day. Thus, we have shown that the advantages of PCL scaffolds are excellent endothelialization and good surgical outcome. The disadvantages include their slow biodegradation, ineffective cellularization, and risks for mineralization and intimal hyperplasia. MDPI 2022-08-15 /pmc/articles/PMC9412484/ /pubmed/36015570 http://dx.doi.org/10.3390/polym14163313 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Dokuchaeva, Anna A.
Mochalova, Aleksandra B.
Timchenko, Tatyana P.
Podolskaya, Kseniya S.
Pashkovskaya, Oxana A.
Karpova, Elena V.
Ivanov, Ilya A.
Filatova, Natalya A.
Zhuravleva, Irina Yu
In Vivo Evaluation of PCL Vascular Grafts Implanted in Rat Abdominal Aorta
title In Vivo Evaluation of PCL Vascular Grafts Implanted in Rat Abdominal Aorta
title_full In Vivo Evaluation of PCL Vascular Grafts Implanted in Rat Abdominal Aorta
title_fullStr In Vivo Evaluation of PCL Vascular Grafts Implanted in Rat Abdominal Aorta
title_full_unstemmed In Vivo Evaluation of PCL Vascular Grafts Implanted in Rat Abdominal Aorta
title_short In Vivo Evaluation of PCL Vascular Grafts Implanted in Rat Abdominal Aorta
title_sort in vivo evaluation of pcl vascular grafts implanted in rat abdominal aorta
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9412484/
https://www.ncbi.nlm.nih.gov/pubmed/36015570
http://dx.doi.org/10.3390/polym14163313
work_keys_str_mv AT dokuchaevaannaa invivoevaluationofpclvasculargraftsimplantedinratabdominalaorta
AT mochalovaaleksandrab invivoevaluationofpclvasculargraftsimplantedinratabdominalaorta
AT timchenkotatyanap invivoevaluationofpclvasculargraftsimplantedinratabdominalaorta
AT podolskayakseniyas invivoevaluationofpclvasculargraftsimplantedinratabdominalaorta
AT pashkovskayaoxanaa invivoevaluationofpclvasculargraftsimplantedinratabdominalaorta
AT karpovaelenav invivoevaluationofpclvasculargraftsimplantedinratabdominalaorta
AT ivanovilyaa invivoevaluationofpclvasculargraftsimplantedinratabdominalaorta
AT filatovanatalyaa invivoevaluationofpclvasculargraftsimplantedinratabdominalaorta
AT zhuravlevairinayu invivoevaluationofpclvasculargraftsimplantedinratabdominalaorta