Cargando…

Experimental Study of Maintenance-Free Steel-Composite Buckling Restrained Braces

High-rise buildings are very flexible, have a small damping, and respond significantly under strong dynamic load. However, there is a lack of studies about buckling restrained braces (BRBs) used in high-rise buildings, towering steel structures, and bridge structures. In this paper, the authors put...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhao, Jun, Wang, Huiping, Dong, Jun, Zhang, Liwei
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9413471/
https://www.ncbi.nlm.nih.gov/pubmed/36013674
http://dx.doi.org/10.3390/ma15165538
_version_ 1784775760150528000
author Zhao, Jun
Wang, Huiping
Dong, Jun
Zhang, Liwei
author_facet Zhao, Jun
Wang, Huiping
Dong, Jun
Zhang, Liwei
author_sort Zhao, Jun
collection PubMed
description High-rise buildings are very flexible, have a small damping, and respond significantly under strong dynamic load. However, there is a lack of studies about buckling restrained braces (BRBs) used in high-rise buildings, towering steel structures, and bridge structures. In this paper, the authors put forward a new type of brace, the maintenance-free steel-composite buckling restrained brace (MFSC-BRB). The MFSC-BRB has a steel plate core, for which a ribbed glass fiber reinforced polymer (GFRP) rectangular tube is used as the restraint unit; the steel core is encapsulated by the GFRP rectangular tube. In this study, MFSC-BRBs were fabricated using a vacuum-infused molding process that enabled them to be integrally formed all at once. Four specimens were designed according to the vacuum-infused molding process; then, the failure mode, deformation capacity, and hysteretic behavior of the MFSC-BRBs were studied. The results showed that the new MFSC-BRB has good integrity and good energy dissipation capacity under the action of a low weekly repeated loading effect. When the axial displacement is large, the performance of the single wave section expansion joint is better than that of the double wave section expansion joint. The greater the restraint ratio of the restrained yield section, the greater the energy dissipation of the brace. The proposed MFSC-BRBs have good integrity and are lightweight compared with traditional BRBs.
format Online
Article
Text
id pubmed-9413471
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-94134712022-08-27 Experimental Study of Maintenance-Free Steel-Composite Buckling Restrained Braces Zhao, Jun Wang, Huiping Dong, Jun Zhang, Liwei Materials (Basel) Article High-rise buildings are very flexible, have a small damping, and respond significantly under strong dynamic load. However, there is a lack of studies about buckling restrained braces (BRBs) used in high-rise buildings, towering steel structures, and bridge structures. In this paper, the authors put forward a new type of brace, the maintenance-free steel-composite buckling restrained brace (MFSC-BRB). The MFSC-BRB has a steel plate core, for which a ribbed glass fiber reinforced polymer (GFRP) rectangular tube is used as the restraint unit; the steel core is encapsulated by the GFRP rectangular tube. In this study, MFSC-BRBs were fabricated using a vacuum-infused molding process that enabled them to be integrally formed all at once. Four specimens were designed according to the vacuum-infused molding process; then, the failure mode, deformation capacity, and hysteretic behavior of the MFSC-BRBs were studied. The results showed that the new MFSC-BRB has good integrity and good energy dissipation capacity under the action of a low weekly repeated loading effect. When the axial displacement is large, the performance of the single wave section expansion joint is better than that of the double wave section expansion joint. The greater the restraint ratio of the restrained yield section, the greater the energy dissipation of the brace. The proposed MFSC-BRBs have good integrity and are lightweight compared with traditional BRBs. MDPI 2022-08-11 /pmc/articles/PMC9413471/ /pubmed/36013674 http://dx.doi.org/10.3390/ma15165538 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Zhao, Jun
Wang, Huiping
Dong, Jun
Zhang, Liwei
Experimental Study of Maintenance-Free Steel-Composite Buckling Restrained Braces
title Experimental Study of Maintenance-Free Steel-Composite Buckling Restrained Braces
title_full Experimental Study of Maintenance-Free Steel-Composite Buckling Restrained Braces
title_fullStr Experimental Study of Maintenance-Free Steel-Composite Buckling Restrained Braces
title_full_unstemmed Experimental Study of Maintenance-Free Steel-Composite Buckling Restrained Braces
title_short Experimental Study of Maintenance-Free Steel-Composite Buckling Restrained Braces
title_sort experimental study of maintenance-free steel-composite buckling restrained braces
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9413471/
https://www.ncbi.nlm.nih.gov/pubmed/36013674
http://dx.doi.org/10.3390/ma15165538
work_keys_str_mv AT zhaojun experimentalstudyofmaintenancefreesteelcompositebucklingrestrainedbraces
AT wanghuiping experimentalstudyofmaintenancefreesteelcompositebucklingrestrainedbraces
AT dongjun experimentalstudyofmaintenancefreesteelcompositebucklingrestrainedbraces
AT zhangliwei experimentalstudyofmaintenancefreesteelcompositebucklingrestrainedbraces