Cargando…
Comparison of Anatomical Conformity between TomoFix Anatomical Plate and TomoFix Conventional Plate in Open-Wedge High Tibial Osteotomy
Background and Objectives: The TomoFix anatomical plate was developed to improve plate position, proximal screw direction, and post-correction tibial contouring. The purpose of this study was to compare postoperative configurations between the TomoFix anatomical plate and the TomoFix conventional pl...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9413536/ https://www.ncbi.nlm.nih.gov/pubmed/36013511 http://dx.doi.org/10.3390/medicina58081045 |
_version_ | 1784775773390897152 |
---|---|
author | Lee, Sung-Sahn Park, Jaesung Lee, Dae-Hee |
author_facet | Lee, Sung-Sahn Park, Jaesung Lee, Dae-Hee |
author_sort | Lee, Sung-Sahn |
collection | PubMed |
description | Background and Objectives: The TomoFix anatomical plate was developed to improve plate position, proximal screw direction, and post-correction tibial contouring. The purpose of this study was to compare postoperative configurations between the TomoFix anatomical plate and the TomoFix conventional plate. It was hypothesized that the new modified plate provides a better fixative coaptation than the conventional plate. Materials and Methods: A total of 116 cases (112 patients) were enrolled in this study from March 2015 to February 2021. Among them, 63 patients underwent surgery using the TomoFix conventional plate, and 53 underwent surgery using the TomoFix anatomical plate. The radiographic outcomes, including the hip–knee–ankle (HKA) angle, medial proximal tibial angle (MPTA), tibial slope, plate angle, proximal screw angles, and plate-to-cortex distance at #1 hole (just below the osteotomy site) were compared between the two groups. Results: Patients with the TomoFix anatomical plate showed similar results in terms of the pre- and postoperative HKA angle, MPTA, and tibial slope. The TomoFix anatomical group showed a significantly greater plate angle (39.2° ± 8.1° vs. 31.7° ± 7.0°, p < 0.001) and less screw angles, indicating that the TomoFix anatomical plates allowed a more posterior plate position than the conventional plate. The plate-to-cortex distance was significantly less in the TomoFix anatomical group than in the TomoFix conventional group (p < 0.001). Conclusion: The TomoFix anatomical plate showed a more posteromedial plating position, better proximal screw direction to the lateral hinge, and improved post-correction tibial contour compared to the TomoFix conventional plate. |
format | Online Article Text |
id | pubmed-9413536 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-94135362022-08-27 Comparison of Anatomical Conformity between TomoFix Anatomical Plate and TomoFix Conventional Plate in Open-Wedge High Tibial Osteotomy Lee, Sung-Sahn Park, Jaesung Lee, Dae-Hee Medicina (Kaunas) Article Background and Objectives: The TomoFix anatomical plate was developed to improve plate position, proximal screw direction, and post-correction tibial contouring. The purpose of this study was to compare postoperative configurations between the TomoFix anatomical plate and the TomoFix conventional plate. It was hypothesized that the new modified plate provides a better fixative coaptation than the conventional plate. Materials and Methods: A total of 116 cases (112 patients) were enrolled in this study from March 2015 to February 2021. Among them, 63 patients underwent surgery using the TomoFix conventional plate, and 53 underwent surgery using the TomoFix anatomical plate. The radiographic outcomes, including the hip–knee–ankle (HKA) angle, medial proximal tibial angle (MPTA), tibial slope, plate angle, proximal screw angles, and plate-to-cortex distance at #1 hole (just below the osteotomy site) were compared between the two groups. Results: Patients with the TomoFix anatomical plate showed similar results in terms of the pre- and postoperative HKA angle, MPTA, and tibial slope. The TomoFix anatomical group showed a significantly greater plate angle (39.2° ± 8.1° vs. 31.7° ± 7.0°, p < 0.001) and less screw angles, indicating that the TomoFix anatomical plates allowed a more posterior plate position than the conventional plate. The plate-to-cortex distance was significantly less in the TomoFix anatomical group than in the TomoFix conventional group (p < 0.001). Conclusion: The TomoFix anatomical plate showed a more posteromedial plating position, better proximal screw direction to the lateral hinge, and improved post-correction tibial contour compared to the TomoFix conventional plate. MDPI 2022-08-03 /pmc/articles/PMC9413536/ /pubmed/36013511 http://dx.doi.org/10.3390/medicina58081045 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Lee, Sung-Sahn Park, Jaesung Lee, Dae-Hee Comparison of Anatomical Conformity between TomoFix Anatomical Plate and TomoFix Conventional Plate in Open-Wedge High Tibial Osteotomy |
title | Comparison of Anatomical Conformity between TomoFix Anatomical Plate and TomoFix Conventional Plate in Open-Wedge High Tibial Osteotomy |
title_full | Comparison of Anatomical Conformity between TomoFix Anatomical Plate and TomoFix Conventional Plate in Open-Wedge High Tibial Osteotomy |
title_fullStr | Comparison of Anatomical Conformity between TomoFix Anatomical Plate and TomoFix Conventional Plate in Open-Wedge High Tibial Osteotomy |
title_full_unstemmed | Comparison of Anatomical Conformity between TomoFix Anatomical Plate and TomoFix Conventional Plate in Open-Wedge High Tibial Osteotomy |
title_short | Comparison of Anatomical Conformity between TomoFix Anatomical Plate and TomoFix Conventional Plate in Open-Wedge High Tibial Osteotomy |
title_sort | comparison of anatomical conformity between tomofix anatomical plate and tomofix conventional plate in open-wedge high tibial osteotomy |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9413536/ https://www.ncbi.nlm.nih.gov/pubmed/36013511 http://dx.doi.org/10.3390/medicina58081045 |
work_keys_str_mv | AT leesungsahn comparisonofanatomicalconformitybetweentomofixanatomicalplateandtomofixconventionalplateinopenwedgehightibialosteotomy AT parkjaesung comparisonofanatomicalconformitybetweentomofixanatomicalplateandtomofixconventionalplateinopenwedgehightibialosteotomy AT leedaehee comparisonofanatomicalconformitybetweentomofixanatomicalplateandtomofixconventionalplateinopenwedgehightibialosteotomy |