Cargando…

Comparison of Anatomical Conformity between TomoFix Anatomical Plate and TomoFix Conventional Plate in Open-Wedge High Tibial Osteotomy

Background and Objectives: The TomoFix anatomical plate was developed to improve plate position, proximal screw direction, and post-correction tibial contouring. The purpose of this study was to compare postoperative configurations between the TomoFix anatomical plate and the TomoFix conventional pl...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Sung-Sahn, Park, Jaesung, Lee, Dae-Hee
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9413536/
https://www.ncbi.nlm.nih.gov/pubmed/36013511
http://dx.doi.org/10.3390/medicina58081045
_version_ 1784775773390897152
author Lee, Sung-Sahn
Park, Jaesung
Lee, Dae-Hee
author_facet Lee, Sung-Sahn
Park, Jaesung
Lee, Dae-Hee
author_sort Lee, Sung-Sahn
collection PubMed
description Background and Objectives: The TomoFix anatomical plate was developed to improve plate position, proximal screw direction, and post-correction tibial contouring. The purpose of this study was to compare postoperative configurations between the TomoFix anatomical plate and the TomoFix conventional plate. It was hypothesized that the new modified plate provides a better fixative coaptation than the conventional plate. Materials and Methods: A total of 116 cases (112 patients) were enrolled in this study from March 2015 to February 2021. Among them, 63 patients underwent surgery using the TomoFix conventional plate, and 53 underwent surgery using the TomoFix anatomical plate. The radiographic outcomes, including the hip–knee–ankle (HKA) angle, medial proximal tibial angle (MPTA), tibial slope, plate angle, proximal screw angles, and plate-to-cortex distance at #1 hole (just below the osteotomy site) were compared between the two groups. Results: Patients with the TomoFix anatomical plate showed similar results in terms of the pre- and postoperative HKA angle, MPTA, and tibial slope. The TomoFix anatomical group showed a significantly greater plate angle (39.2° ± 8.1° vs. 31.7° ± 7.0°, p < 0.001) and less screw angles, indicating that the TomoFix anatomical plates allowed a more posterior plate position than the conventional plate. The plate-to-cortex distance was significantly less in the TomoFix anatomical group than in the TomoFix conventional group (p < 0.001). Conclusion: The TomoFix anatomical plate showed a more posteromedial plating position, better proximal screw direction to the lateral hinge, and improved post-correction tibial contour compared to the TomoFix conventional plate.
format Online
Article
Text
id pubmed-9413536
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-94135362022-08-27 Comparison of Anatomical Conformity between TomoFix Anatomical Plate and TomoFix Conventional Plate in Open-Wedge High Tibial Osteotomy Lee, Sung-Sahn Park, Jaesung Lee, Dae-Hee Medicina (Kaunas) Article Background and Objectives: The TomoFix anatomical plate was developed to improve plate position, proximal screw direction, and post-correction tibial contouring. The purpose of this study was to compare postoperative configurations between the TomoFix anatomical plate and the TomoFix conventional plate. It was hypothesized that the new modified plate provides a better fixative coaptation than the conventional plate. Materials and Methods: A total of 116 cases (112 patients) were enrolled in this study from March 2015 to February 2021. Among them, 63 patients underwent surgery using the TomoFix conventional plate, and 53 underwent surgery using the TomoFix anatomical plate. The radiographic outcomes, including the hip–knee–ankle (HKA) angle, medial proximal tibial angle (MPTA), tibial slope, plate angle, proximal screw angles, and plate-to-cortex distance at #1 hole (just below the osteotomy site) were compared between the two groups. Results: Patients with the TomoFix anatomical plate showed similar results in terms of the pre- and postoperative HKA angle, MPTA, and tibial slope. The TomoFix anatomical group showed a significantly greater plate angle (39.2° ± 8.1° vs. 31.7° ± 7.0°, p < 0.001) and less screw angles, indicating that the TomoFix anatomical plates allowed a more posterior plate position than the conventional plate. The plate-to-cortex distance was significantly less in the TomoFix anatomical group than in the TomoFix conventional group (p < 0.001). Conclusion: The TomoFix anatomical plate showed a more posteromedial plating position, better proximal screw direction to the lateral hinge, and improved post-correction tibial contour compared to the TomoFix conventional plate. MDPI 2022-08-03 /pmc/articles/PMC9413536/ /pubmed/36013511 http://dx.doi.org/10.3390/medicina58081045 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Lee, Sung-Sahn
Park, Jaesung
Lee, Dae-Hee
Comparison of Anatomical Conformity between TomoFix Anatomical Plate and TomoFix Conventional Plate in Open-Wedge High Tibial Osteotomy
title Comparison of Anatomical Conformity between TomoFix Anatomical Plate and TomoFix Conventional Plate in Open-Wedge High Tibial Osteotomy
title_full Comparison of Anatomical Conformity between TomoFix Anatomical Plate and TomoFix Conventional Plate in Open-Wedge High Tibial Osteotomy
title_fullStr Comparison of Anatomical Conformity between TomoFix Anatomical Plate and TomoFix Conventional Plate in Open-Wedge High Tibial Osteotomy
title_full_unstemmed Comparison of Anatomical Conformity between TomoFix Anatomical Plate and TomoFix Conventional Plate in Open-Wedge High Tibial Osteotomy
title_short Comparison of Anatomical Conformity between TomoFix Anatomical Plate and TomoFix Conventional Plate in Open-Wedge High Tibial Osteotomy
title_sort comparison of anatomical conformity between tomofix anatomical plate and tomofix conventional plate in open-wedge high tibial osteotomy
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9413536/
https://www.ncbi.nlm.nih.gov/pubmed/36013511
http://dx.doi.org/10.3390/medicina58081045
work_keys_str_mv AT leesungsahn comparisonofanatomicalconformitybetweentomofixanatomicalplateandtomofixconventionalplateinopenwedgehightibialosteotomy
AT parkjaesung comparisonofanatomicalconformitybetweentomofixanatomicalplateandtomofixconventionalplateinopenwedgehightibialosteotomy
AT leedaehee comparisonofanatomicalconformitybetweentomofixanatomicalplateandtomofixconventionalplateinopenwedgehightibialosteotomy