Cargando…

Real-Time Reflectance Measurement Using an Astigmatic Optical Profilometer

An astigmatic optical profilometer with a commercial optical pickup head provides benefits, such as high resolution, compact size, and low cost. To eliminate artifacts caused by complex materials with different reflectances, a z-axis modulation mode is proposed to obtain quantitative surface morphol...

Descripción completa

Detalles Bibliográficos
Autores principales: Liao, Hsien-Shun, Huang, Ya-Kang, Syu-Gu, Jian-Yuan, Hwu, En-Te
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9414481/
https://www.ncbi.nlm.nih.gov/pubmed/36016000
http://dx.doi.org/10.3390/s22166242
_version_ 1784775998196154368
author Liao, Hsien-Shun
Huang, Ya-Kang
Syu-Gu, Jian-Yuan
Hwu, En-Te
author_facet Liao, Hsien-Shun
Huang, Ya-Kang
Syu-Gu, Jian-Yuan
Hwu, En-Te
author_sort Liao, Hsien-Shun
collection PubMed
description An astigmatic optical profilometer with a commercial optical pickup head provides benefits, such as high resolution, compact size, and low cost. To eliminate artifacts caused by complex materials with different reflectances, a z-axis modulation mode is proposed to obtain quantitative surface morphology by measuring S curves on all image pixels. Moreover, the slope of the linear region in the S curve shows a positive relationship with the surface reflectance. However, the slope was calculated using an offline curve fitting method, which did not allow real-time reflectance imaging. Furthermore, quantitative reflectance data were unavailable because of the lack of calibration. In this study, we propose a novel method for real-time reflectance imaging by measuring the amplitude of a focus error signal (FES). The calibration results displayed a linear relationship between the FES amplitude and reflectance. The reflectance image of a grating sample with chrome patterns on a glass substrate demonstrates accurate reflectance measurements with a micrometer spatial resolution.
format Online
Article
Text
id pubmed-9414481
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-94144812022-08-27 Real-Time Reflectance Measurement Using an Astigmatic Optical Profilometer Liao, Hsien-Shun Huang, Ya-Kang Syu-Gu, Jian-Yuan Hwu, En-Te Sensors (Basel) Communication An astigmatic optical profilometer with a commercial optical pickup head provides benefits, such as high resolution, compact size, and low cost. To eliminate artifacts caused by complex materials with different reflectances, a z-axis modulation mode is proposed to obtain quantitative surface morphology by measuring S curves on all image pixels. Moreover, the slope of the linear region in the S curve shows a positive relationship with the surface reflectance. However, the slope was calculated using an offline curve fitting method, which did not allow real-time reflectance imaging. Furthermore, quantitative reflectance data were unavailable because of the lack of calibration. In this study, we propose a novel method for real-time reflectance imaging by measuring the amplitude of a focus error signal (FES). The calibration results displayed a linear relationship between the FES amplitude and reflectance. The reflectance image of a grating sample with chrome patterns on a glass substrate demonstrates accurate reflectance measurements with a micrometer spatial resolution. MDPI 2022-08-19 /pmc/articles/PMC9414481/ /pubmed/36016000 http://dx.doi.org/10.3390/s22166242 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Communication
Liao, Hsien-Shun
Huang, Ya-Kang
Syu-Gu, Jian-Yuan
Hwu, En-Te
Real-Time Reflectance Measurement Using an Astigmatic Optical Profilometer
title Real-Time Reflectance Measurement Using an Astigmatic Optical Profilometer
title_full Real-Time Reflectance Measurement Using an Astigmatic Optical Profilometer
title_fullStr Real-Time Reflectance Measurement Using an Astigmatic Optical Profilometer
title_full_unstemmed Real-Time Reflectance Measurement Using an Astigmatic Optical Profilometer
title_short Real-Time Reflectance Measurement Using an Astigmatic Optical Profilometer
title_sort real-time reflectance measurement using an astigmatic optical profilometer
topic Communication
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9414481/
https://www.ncbi.nlm.nih.gov/pubmed/36016000
http://dx.doi.org/10.3390/s22166242
work_keys_str_mv AT liaohsienshun realtimereflectancemeasurementusinganastigmaticopticalprofilometer
AT huangyakang realtimereflectancemeasurementusinganastigmaticopticalprofilometer
AT syugujianyuan realtimereflectancemeasurementusinganastigmaticopticalprofilometer
AT hwuente realtimereflectancemeasurementusinganastigmaticopticalprofilometer