Cargando…

Integrated Amplitude and Phase Monitor for Micro-Actuators

Micro-actuators driven on resonance maximize reach and speed; however, due to their sensitivity to environmental factors (e.g., temperature and air pressure), the amplitude and phase response must be monitored to achieve an accurate actuator position. We introduce an MEMS (microelectromechanical sys...

Descripción completa

Detalles Bibliográficos
Autores principales: Manosalvas-Kjono, Sandra Nicole, Quan, Ronald, Solgaard, Olav
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9415144/
https://www.ncbi.nlm.nih.gov/pubmed/36014282
http://dx.doi.org/10.3390/mi13081360
_version_ 1784776159621283840
author Manosalvas-Kjono, Sandra Nicole
Quan, Ronald
Solgaard, Olav
author_facet Manosalvas-Kjono, Sandra Nicole
Quan, Ronald
Solgaard, Olav
author_sort Manosalvas-Kjono, Sandra Nicole
collection PubMed
description Micro-actuators driven on resonance maximize reach and speed; however, due to their sensitivity to environmental factors (e.g., temperature and air pressure), the amplitude and phase response must be monitored to achieve an accurate actuator position. We introduce an MEMS (microelectromechanical system) amplitude and phase monitor (MAPM) with a signal-to-noise ratio of 51 dB and 11.0 kHz bandwidth, capable of simultaneously driving and sensing the movement of 1D and 2D electrostatically driven micro-actuators without modifying the chip or its packaging. The operational principle is to electromechanically modulate the amplitude of a high-frequency signal with the changing capacitance of the micro-actuator. MAPM operation is characterized and verified by simultaneously measuring the amplitude and phase frequency response of commercial micromirrors. We demonstrate that the MAPM circuitry is insensitive to complex relationships between capacitance and position of the MEMS actuators, and it is capable of giving real-time read-out of the micromirror motion. Our measurements also reveal and quantify observations of phase drift and crosstalk in 2D resonant operation. Measurements of phase changes over time under normal operation also verify the need for phase monitoring. The open-loop, high-sensitivity position sensor enables detailed characterization of dynamic micro-actuator behavior, leading to new insights and new types of operation, including improved control of nonlinear motion.
format Online
Article
Text
id pubmed-9415144
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-94151442022-08-27 Integrated Amplitude and Phase Monitor for Micro-Actuators Manosalvas-Kjono, Sandra Nicole Quan, Ronald Solgaard, Olav Micromachines (Basel) Article Micro-actuators driven on resonance maximize reach and speed; however, due to their sensitivity to environmental factors (e.g., temperature and air pressure), the amplitude and phase response must be monitored to achieve an accurate actuator position. We introduce an MEMS (microelectromechanical system) amplitude and phase monitor (MAPM) with a signal-to-noise ratio of 51 dB and 11.0 kHz bandwidth, capable of simultaneously driving and sensing the movement of 1D and 2D electrostatically driven micro-actuators without modifying the chip or its packaging. The operational principle is to electromechanically modulate the amplitude of a high-frequency signal with the changing capacitance of the micro-actuator. MAPM operation is characterized and verified by simultaneously measuring the amplitude and phase frequency response of commercial micromirrors. We demonstrate that the MAPM circuitry is insensitive to complex relationships between capacitance and position of the MEMS actuators, and it is capable of giving real-time read-out of the micromirror motion. Our measurements also reveal and quantify observations of phase drift and crosstalk in 2D resonant operation. Measurements of phase changes over time under normal operation also verify the need for phase monitoring. The open-loop, high-sensitivity position sensor enables detailed characterization of dynamic micro-actuator behavior, leading to new insights and new types of operation, including improved control of nonlinear motion. MDPI 2022-08-20 /pmc/articles/PMC9415144/ /pubmed/36014282 http://dx.doi.org/10.3390/mi13081360 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Manosalvas-Kjono, Sandra Nicole
Quan, Ronald
Solgaard, Olav
Integrated Amplitude and Phase Monitor for Micro-Actuators
title Integrated Amplitude and Phase Monitor for Micro-Actuators
title_full Integrated Amplitude and Phase Monitor for Micro-Actuators
title_fullStr Integrated Amplitude and Phase Monitor for Micro-Actuators
title_full_unstemmed Integrated Amplitude and Phase Monitor for Micro-Actuators
title_short Integrated Amplitude and Phase Monitor for Micro-Actuators
title_sort integrated amplitude and phase monitor for micro-actuators
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9415144/
https://www.ncbi.nlm.nih.gov/pubmed/36014282
http://dx.doi.org/10.3390/mi13081360
work_keys_str_mv AT manosalvaskjonosandranicole integratedamplitudeandphasemonitorformicroactuators
AT quanronald integratedamplitudeandphasemonitorformicroactuators
AT solgaardolav integratedamplitudeandphasemonitorformicroactuators