Cargando…
Radiotherapy Target Volume Definition in Newly Diagnosed High-Grade Glioma Using 18F-FET PET Imaging and Multiparametric MRI: An Inter Observer Agreement Study
Background: The aim of this prospective monocentric study was to assess the inter-observer agreement for tumor volume delineations by multiparametric MRI and 18-F-FET-PET/CT in newly diagnosed, untreated high-grade glioma (HGG) patients. Methods: Thirty patients HGG underwent O-(2-[18F]-fluoroethyl)...
Autores principales: | , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9415495/ https://www.ncbi.nlm.nih.gov/pubmed/36006068 http://dx.doi.org/10.3390/tomography8040170 |
_version_ | 1784776245790113792 |
---|---|
author | Dissaux, Brieg Mazouz Fatmi, Doria Ognard, Julien Allard, Bastien Keromnes, Nathalie Latreche, Amina Lepeuve, Amandine Schick, Ulrike Bourbonne, Vincent Ben Salem, Douraied Dissaux, Gurvan Querellou, Solène |
author_facet | Dissaux, Brieg Mazouz Fatmi, Doria Ognard, Julien Allard, Bastien Keromnes, Nathalie Latreche, Amina Lepeuve, Amandine Schick, Ulrike Bourbonne, Vincent Ben Salem, Douraied Dissaux, Gurvan Querellou, Solène |
author_sort | Dissaux, Brieg |
collection | PubMed |
description | Background: The aim of this prospective monocentric study was to assess the inter-observer agreement for tumor volume delineations by multiparametric MRI and 18-F-FET-PET/CT in newly diagnosed, untreated high-grade glioma (HGG) patients. Methods: Thirty patients HGG underwent O-(2-[18F]-fluoroethyl)-l-tyrosine(18F-FET) positron emission tomography (PET), and multiparametric MRI with computation of rCBV map and K2 map. Three nuclear physicians and three radiologists with different levels of experience delineated the 18-F-FET-PET/CT and 6 MRI sequences, respectively. Spatial similarity (Dice and Jaccard: DSC and JSC) and overlap (Overlap: OV) coefficients were calculated between the readers for each sequence. Results: DSC, JSC, and OV were high for 18F-FET PET/CT, T1-GD, and T2-FLAIR (>0.67). The Spearman correlation coefficient between readers was ≥0.6 for these sequences. Cross-comparison of similarity and overlap parameters showed significant differences for DSC and JSC between 18F-FET PET/CT and T2-FLAIR and for JSC between 18F-FET PET/CT and T1-GD with higher values for 18F-FET PET/CT. No significant difference was found between T1-GD and T2-FLAIR. rCBV, K2, b1000, and ADC showed correlation coefficients between readers <0.6. Conclusion: The interobserver agreements for tumor volume delineations were high for 18-F-FET-PET/CT, T1-GD, and T2-FLAIR. The DWI (b1000, ADC), rCBV, and K2-based sequences, as performed, did not seem sufficiently reproducible to be used in daily practice. |
format | Online Article Text |
id | pubmed-9415495 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-94154952022-08-27 Radiotherapy Target Volume Definition in Newly Diagnosed High-Grade Glioma Using 18F-FET PET Imaging and Multiparametric MRI: An Inter Observer Agreement Study Dissaux, Brieg Mazouz Fatmi, Doria Ognard, Julien Allard, Bastien Keromnes, Nathalie Latreche, Amina Lepeuve, Amandine Schick, Ulrike Bourbonne, Vincent Ben Salem, Douraied Dissaux, Gurvan Querellou, Solène Tomography Article Background: The aim of this prospective monocentric study was to assess the inter-observer agreement for tumor volume delineations by multiparametric MRI and 18-F-FET-PET/CT in newly diagnosed, untreated high-grade glioma (HGG) patients. Methods: Thirty patients HGG underwent O-(2-[18F]-fluoroethyl)-l-tyrosine(18F-FET) positron emission tomography (PET), and multiparametric MRI with computation of rCBV map and K2 map. Three nuclear physicians and three radiologists with different levels of experience delineated the 18-F-FET-PET/CT and 6 MRI sequences, respectively. Spatial similarity (Dice and Jaccard: DSC and JSC) and overlap (Overlap: OV) coefficients were calculated between the readers for each sequence. Results: DSC, JSC, and OV were high for 18F-FET PET/CT, T1-GD, and T2-FLAIR (>0.67). The Spearman correlation coefficient between readers was ≥0.6 for these sequences. Cross-comparison of similarity and overlap parameters showed significant differences for DSC and JSC between 18F-FET PET/CT and T2-FLAIR and for JSC between 18F-FET PET/CT and T1-GD with higher values for 18F-FET PET/CT. No significant difference was found between T1-GD and T2-FLAIR. rCBV, K2, b1000, and ADC showed correlation coefficients between readers <0.6. Conclusion: The interobserver agreements for tumor volume delineations were high for 18-F-FET-PET/CT, T1-GD, and T2-FLAIR. The DWI (b1000, ADC), rCBV, and K2-based sequences, as performed, did not seem sufficiently reproducible to be used in daily practice. MDPI 2022-08-16 /pmc/articles/PMC9415495/ /pubmed/36006068 http://dx.doi.org/10.3390/tomography8040170 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Dissaux, Brieg Mazouz Fatmi, Doria Ognard, Julien Allard, Bastien Keromnes, Nathalie Latreche, Amina Lepeuve, Amandine Schick, Ulrike Bourbonne, Vincent Ben Salem, Douraied Dissaux, Gurvan Querellou, Solène Radiotherapy Target Volume Definition in Newly Diagnosed High-Grade Glioma Using 18F-FET PET Imaging and Multiparametric MRI: An Inter Observer Agreement Study |
title | Radiotherapy Target Volume Definition in Newly Diagnosed High-Grade Glioma Using 18F-FET PET Imaging and Multiparametric MRI: An Inter Observer Agreement Study |
title_full | Radiotherapy Target Volume Definition in Newly Diagnosed High-Grade Glioma Using 18F-FET PET Imaging and Multiparametric MRI: An Inter Observer Agreement Study |
title_fullStr | Radiotherapy Target Volume Definition in Newly Diagnosed High-Grade Glioma Using 18F-FET PET Imaging and Multiparametric MRI: An Inter Observer Agreement Study |
title_full_unstemmed | Radiotherapy Target Volume Definition in Newly Diagnosed High-Grade Glioma Using 18F-FET PET Imaging and Multiparametric MRI: An Inter Observer Agreement Study |
title_short | Radiotherapy Target Volume Definition in Newly Diagnosed High-Grade Glioma Using 18F-FET PET Imaging and Multiparametric MRI: An Inter Observer Agreement Study |
title_sort | radiotherapy target volume definition in newly diagnosed high-grade glioma using 18f-fet pet imaging and multiparametric mri: an inter observer agreement study |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9415495/ https://www.ncbi.nlm.nih.gov/pubmed/36006068 http://dx.doi.org/10.3390/tomography8040170 |
work_keys_str_mv | AT dissauxbrieg radiotherapytargetvolumedefinitioninnewlydiagnosedhighgradegliomausing18ffetpetimagingandmultiparametricmrianinterobserveragreementstudy AT mazouzfatmidoria radiotherapytargetvolumedefinitioninnewlydiagnosedhighgradegliomausing18ffetpetimagingandmultiparametricmrianinterobserveragreementstudy AT ognardjulien radiotherapytargetvolumedefinitioninnewlydiagnosedhighgradegliomausing18ffetpetimagingandmultiparametricmrianinterobserveragreementstudy AT allardbastien radiotherapytargetvolumedefinitioninnewlydiagnosedhighgradegliomausing18ffetpetimagingandmultiparametricmrianinterobserveragreementstudy AT keromnesnathalie radiotherapytargetvolumedefinitioninnewlydiagnosedhighgradegliomausing18ffetpetimagingandmultiparametricmrianinterobserveragreementstudy AT latrecheamina radiotherapytargetvolumedefinitioninnewlydiagnosedhighgradegliomausing18ffetpetimagingandmultiparametricmrianinterobserveragreementstudy AT lepeuveamandine radiotherapytargetvolumedefinitioninnewlydiagnosedhighgradegliomausing18ffetpetimagingandmultiparametricmrianinterobserveragreementstudy AT schickulrike radiotherapytargetvolumedefinitioninnewlydiagnosedhighgradegliomausing18ffetpetimagingandmultiparametricmrianinterobserveragreementstudy AT bourbonnevincent radiotherapytargetvolumedefinitioninnewlydiagnosedhighgradegliomausing18ffetpetimagingandmultiparametricmrianinterobserveragreementstudy AT bensalemdouraied radiotherapytargetvolumedefinitioninnewlydiagnosedhighgradegliomausing18ffetpetimagingandmultiparametricmrianinterobserveragreementstudy AT dissauxgurvan radiotherapytargetvolumedefinitioninnewlydiagnosedhighgradegliomausing18ffetpetimagingandmultiparametricmrianinterobserveragreementstudy AT querellousolene radiotherapytargetvolumedefinitioninnewlydiagnosedhighgradegliomausing18ffetpetimagingandmultiparametricmrianinterobserveragreementstudy |