Cargando…

Characterization of Tensile Stress-Dependent Directional Magnetic Incremental Permeability in Iron-Cobalt Magnetic Sheet: Towards Internal Stress Estimation through Non-Destructive Testing

Iron-Cobalt ferromagnetic alloys are promoted for electrical energy conversion in aeronautic applications, but their high magnetostrictive coefficients may result in undesired behaviors. Internal stresses can be tuned to limit magnetostriction but must be adequately assessed in a non-destructive way...

Descripción completa

Detalles Bibliográficos
Autores principales: Toutsop, Borel, Ducharne, Benjamin, Lallart, Mickael, Morel, Laurent, Tsafack, Pierre
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9416037/
https://www.ncbi.nlm.nih.gov/pubmed/36016058
http://dx.doi.org/10.3390/s22166296
_version_ 1784776380768059392
author Toutsop, Borel
Ducharne, Benjamin
Lallart, Mickael
Morel, Laurent
Tsafack, Pierre
author_facet Toutsop, Borel
Ducharne, Benjamin
Lallart, Mickael
Morel, Laurent
Tsafack, Pierre
author_sort Toutsop, Borel
collection PubMed
description Iron-Cobalt ferromagnetic alloys are promoted for electrical energy conversion in aeronautic applications, but their high magnetostrictive coefficients may result in undesired behaviors. Internal stresses can be tuned to limit magnetostriction but must be adequately assessed in a non-destructive way during production. For this, directional magnetic incremental permeability is proposed in this work. For academic purposes, internal stresses have been replaced by homogenous external stress, which is easier to control using traction/compression testbench and results in similar effects. Tests have been limited to tensile stress stimuli, the worst-case scenario for magnetic stress observation on positive magnetostriction coefficient materials. Hysteresis cycles have been reconstructed from the incremental permeability measurement for stability and reproducibility of the measured quantities. The directionality of the sensor provides an additional degree of freedom in the magnetic response observation. The study reveals that an angle of π/2 between the DC (H(surf DC)) and the AC (H(surf AC)) magnetic excitations with a flux density B(a) at H(surf) (DC) = 10 kA·m(−1) constitute the ideal experimental situation and the highest correlated parameter to a homogeneous imposed tensile stress. Magnetic incremental permeability is linked to the magnetic domain wall bulging magnetization mechanism; this study thus provides insights for understanding such a mechanism.
format Online
Article
Text
id pubmed-9416037
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-94160372022-08-27 Characterization of Tensile Stress-Dependent Directional Magnetic Incremental Permeability in Iron-Cobalt Magnetic Sheet: Towards Internal Stress Estimation through Non-Destructive Testing Toutsop, Borel Ducharne, Benjamin Lallart, Mickael Morel, Laurent Tsafack, Pierre Sensors (Basel) Article Iron-Cobalt ferromagnetic alloys are promoted for electrical energy conversion in aeronautic applications, but their high magnetostrictive coefficients may result in undesired behaviors. Internal stresses can be tuned to limit magnetostriction but must be adequately assessed in a non-destructive way during production. For this, directional magnetic incremental permeability is proposed in this work. For academic purposes, internal stresses have been replaced by homogenous external stress, which is easier to control using traction/compression testbench and results in similar effects. Tests have been limited to tensile stress stimuli, the worst-case scenario for magnetic stress observation on positive magnetostriction coefficient materials. Hysteresis cycles have been reconstructed from the incremental permeability measurement for stability and reproducibility of the measured quantities. The directionality of the sensor provides an additional degree of freedom in the magnetic response observation. The study reveals that an angle of π/2 between the DC (H(surf DC)) and the AC (H(surf AC)) magnetic excitations with a flux density B(a) at H(surf) (DC) = 10 kA·m(−1) constitute the ideal experimental situation and the highest correlated parameter to a homogeneous imposed tensile stress. Magnetic incremental permeability is linked to the magnetic domain wall bulging magnetization mechanism; this study thus provides insights for understanding such a mechanism. MDPI 2022-08-21 /pmc/articles/PMC9416037/ /pubmed/36016058 http://dx.doi.org/10.3390/s22166296 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Toutsop, Borel
Ducharne, Benjamin
Lallart, Mickael
Morel, Laurent
Tsafack, Pierre
Characterization of Tensile Stress-Dependent Directional Magnetic Incremental Permeability in Iron-Cobalt Magnetic Sheet: Towards Internal Stress Estimation through Non-Destructive Testing
title Characterization of Tensile Stress-Dependent Directional Magnetic Incremental Permeability in Iron-Cobalt Magnetic Sheet: Towards Internal Stress Estimation through Non-Destructive Testing
title_full Characterization of Tensile Stress-Dependent Directional Magnetic Incremental Permeability in Iron-Cobalt Magnetic Sheet: Towards Internal Stress Estimation through Non-Destructive Testing
title_fullStr Characterization of Tensile Stress-Dependent Directional Magnetic Incremental Permeability in Iron-Cobalt Magnetic Sheet: Towards Internal Stress Estimation through Non-Destructive Testing
title_full_unstemmed Characterization of Tensile Stress-Dependent Directional Magnetic Incremental Permeability in Iron-Cobalt Magnetic Sheet: Towards Internal Stress Estimation through Non-Destructive Testing
title_short Characterization of Tensile Stress-Dependent Directional Magnetic Incremental Permeability in Iron-Cobalt Magnetic Sheet: Towards Internal Stress Estimation through Non-Destructive Testing
title_sort characterization of tensile stress-dependent directional magnetic incremental permeability in iron-cobalt magnetic sheet: towards internal stress estimation through non-destructive testing
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9416037/
https://www.ncbi.nlm.nih.gov/pubmed/36016058
http://dx.doi.org/10.3390/s22166296
work_keys_str_mv AT toutsopborel characterizationoftensilestressdependentdirectionalmagneticincrementalpermeabilityinironcobaltmagneticsheettowardsinternalstressestimationthroughnondestructivetesting
AT ducharnebenjamin characterizationoftensilestressdependentdirectionalmagneticincrementalpermeabilityinironcobaltmagneticsheettowardsinternalstressestimationthroughnondestructivetesting
AT lallartmickael characterizationoftensilestressdependentdirectionalmagneticincrementalpermeabilityinironcobaltmagneticsheettowardsinternalstressestimationthroughnondestructivetesting
AT morellaurent characterizationoftensilestressdependentdirectionalmagneticincrementalpermeabilityinironcobaltmagneticsheettowardsinternalstressestimationthroughnondestructivetesting
AT tsafackpierre characterizationoftensilestressdependentdirectionalmagneticincrementalpermeabilityinironcobaltmagneticsheettowardsinternalstressestimationthroughnondestructivetesting