Cargando…

A study of quantitative indicators for slice sorting in cine-mode 4DCT

The uncertainties of four-dimensional computed tomography (4DCT), also called as residual motion artefacts (RMA), induced from irregular respiratory patterns can degrade the quality of overall radiotherapy. This study aims to quantify and reduce those uncertainties. A comparative study on quantitati...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, Changhwan, Kim, Hojae, Kim, Sung-woo, Goh, Youngmoon, Park, Min-jae, Kim, Hojin, Jeong, Chiyoung, Cho, Byungchul, Choi, Eun Kyung, Lee, Sang-wook, Yoon, Sang Min, Kim, Su Ssan, Park, Jin-hong, Jung, Jinhong, Song, Si Yeol, Kwak, Jungwon
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9417040/
https://www.ncbi.nlm.nih.gov/pubmed/36026490
http://dx.doi.org/10.1371/journal.pone.0272639
_version_ 1784776612288397312
author Kim, Changhwan
Kim, Hojae
Kim, Sung-woo
Goh, Youngmoon
Park, Min-jae
Kim, Hojin
Jeong, Chiyoung
Cho, Byungchul
Choi, Eun Kyung
Lee, Sang-wook
Yoon, Sang Min
Kim, Su Ssan
Park, Jin-hong
Jung, Jinhong
Song, Si Yeol
Kwak, Jungwon
author_facet Kim, Changhwan
Kim, Hojae
Kim, Sung-woo
Goh, Youngmoon
Park, Min-jae
Kim, Hojin
Jeong, Chiyoung
Cho, Byungchul
Choi, Eun Kyung
Lee, Sang-wook
Yoon, Sang Min
Kim, Su Ssan
Park, Jin-hong
Jung, Jinhong
Song, Si Yeol
Kwak, Jungwon
author_sort Kim, Changhwan
collection PubMed
description The uncertainties of four-dimensional computed tomography (4DCT), also called as residual motion artefacts (RMA), induced from irregular respiratory patterns can degrade the quality of overall radiotherapy. This study aims to quantify and reduce those uncertainties. A comparative study on quantitative indicators for RMA was performed, and based on this, we proposed a new 4DCT sorting method that is applicable without disrupting the current clinical workflow. In addition to the default phase sorting strategy, both additional amplitude information from external surrogates and the quantitative metric for RMA, investigated in this study, were introduced. The comparison of quantitative indicators and the performance of the proposed sorting method were evaluated via 10 cases of breath-hold (BH) CT and 30 cases of 4DCT. It was confirmed that N-RMSD (normalised root-mean-square-deviation) was best matched to the visual standards of our institute’s regime, manual sorting method, and could accurately represent RMA. The performance of the proposed method to reduce 4DCT uncertainties was improved by about 18.8% in the averaged value of N-RMSD compared to the default phase sorting method. To the best of our knowledge, this is the first study that evaluates RMA indicators using both BHCT and 4DCT with visual-criteria-based manual sorting and proposes an improved 4DCT sorting strategy based on them.
format Online
Article
Text
id pubmed-9417040
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-94170402022-08-27 A study of quantitative indicators for slice sorting in cine-mode 4DCT Kim, Changhwan Kim, Hojae Kim, Sung-woo Goh, Youngmoon Park, Min-jae Kim, Hojin Jeong, Chiyoung Cho, Byungchul Choi, Eun Kyung Lee, Sang-wook Yoon, Sang Min Kim, Su Ssan Park, Jin-hong Jung, Jinhong Song, Si Yeol Kwak, Jungwon PLoS One Research Article The uncertainties of four-dimensional computed tomography (4DCT), also called as residual motion artefacts (RMA), induced from irregular respiratory patterns can degrade the quality of overall radiotherapy. This study aims to quantify and reduce those uncertainties. A comparative study on quantitative indicators for RMA was performed, and based on this, we proposed a new 4DCT sorting method that is applicable without disrupting the current clinical workflow. In addition to the default phase sorting strategy, both additional amplitude information from external surrogates and the quantitative metric for RMA, investigated in this study, were introduced. The comparison of quantitative indicators and the performance of the proposed sorting method were evaluated via 10 cases of breath-hold (BH) CT and 30 cases of 4DCT. It was confirmed that N-RMSD (normalised root-mean-square-deviation) was best matched to the visual standards of our institute’s regime, manual sorting method, and could accurately represent RMA. The performance of the proposed method to reduce 4DCT uncertainties was improved by about 18.8% in the averaged value of N-RMSD compared to the default phase sorting method. To the best of our knowledge, this is the first study that evaluates RMA indicators using both BHCT and 4DCT with visual-criteria-based manual sorting and proposes an improved 4DCT sorting strategy based on them. Public Library of Science 2022-08-26 /pmc/articles/PMC9417040/ /pubmed/36026490 http://dx.doi.org/10.1371/journal.pone.0272639 Text en © 2022 Kim et al https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Kim, Changhwan
Kim, Hojae
Kim, Sung-woo
Goh, Youngmoon
Park, Min-jae
Kim, Hojin
Jeong, Chiyoung
Cho, Byungchul
Choi, Eun Kyung
Lee, Sang-wook
Yoon, Sang Min
Kim, Su Ssan
Park, Jin-hong
Jung, Jinhong
Song, Si Yeol
Kwak, Jungwon
A study of quantitative indicators for slice sorting in cine-mode 4DCT
title A study of quantitative indicators for slice sorting in cine-mode 4DCT
title_full A study of quantitative indicators for slice sorting in cine-mode 4DCT
title_fullStr A study of quantitative indicators for slice sorting in cine-mode 4DCT
title_full_unstemmed A study of quantitative indicators for slice sorting in cine-mode 4DCT
title_short A study of quantitative indicators for slice sorting in cine-mode 4DCT
title_sort study of quantitative indicators for slice sorting in cine-mode 4dct
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9417040/
https://www.ncbi.nlm.nih.gov/pubmed/36026490
http://dx.doi.org/10.1371/journal.pone.0272639
work_keys_str_mv AT kimchanghwan astudyofquantitativeindicatorsforslicesortingincinemode4dct
AT kimhojae astudyofquantitativeindicatorsforslicesortingincinemode4dct
AT kimsungwoo astudyofquantitativeindicatorsforslicesortingincinemode4dct
AT gohyoungmoon astudyofquantitativeindicatorsforslicesortingincinemode4dct
AT parkminjae astudyofquantitativeindicatorsforslicesortingincinemode4dct
AT kimhojin astudyofquantitativeindicatorsforslicesortingincinemode4dct
AT jeongchiyoung astudyofquantitativeindicatorsforslicesortingincinemode4dct
AT chobyungchul astudyofquantitativeindicatorsforslicesortingincinemode4dct
AT choieunkyung astudyofquantitativeindicatorsforslicesortingincinemode4dct
AT leesangwook astudyofquantitativeindicatorsforslicesortingincinemode4dct
AT yoonsangmin astudyofquantitativeindicatorsforslicesortingincinemode4dct
AT kimsussan astudyofquantitativeindicatorsforslicesortingincinemode4dct
AT parkjinhong astudyofquantitativeindicatorsforslicesortingincinemode4dct
AT jungjinhong astudyofquantitativeindicatorsforslicesortingincinemode4dct
AT songsiyeol astudyofquantitativeindicatorsforslicesortingincinemode4dct
AT kwakjungwon astudyofquantitativeindicatorsforslicesortingincinemode4dct
AT kimchanghwan studyofquantitativeindicatorsforslicesortingincinemode4dct
AT kimhojae studyofquantitativeindicatorsforslicesortingincinemode4dct
AT kimsungwoo studyofquantitativeindicatorsforslicesortingincinemode4dct
AT gohyoungmoon studyofquantitativeindicatorsforslicesortingincinemode4dct
AT parkminjae studyofquantitativeindicatorsforslicesortingincinemode4dct
AT kimhojin studyofquantitativeindicatorsforslicesortingincinemode4dct
AT jeongchiyoung studyofquantitativeindicatorsforslicesortingincinemode4dct
AT chobyungchul studyofquantitativeindicatorsforslicesortingincinemode4dct
AT choieunkyung studyofquantitativeindicatorsforslicesortingincinemode4dct
AT leesangwook studyofquantitativeindicatorsforslicesortingincinemode4dct
AT yoonsangmin studyofquantitativeindicatorsforslicesortingincinemode4dct
AT kimsussan studyofquantitativeindicatorsforslicesortingincinemode4dct
AT parkjinhong studyofquantitativeindicatorsforslicesortingincinemode4dct
AT jungjinhong studyofquantitativeindicatorsforslicesortingincinemode4dct
AT songsiyeol studyofquantitativeindicatorsforslicesortingincinemode4dct
AT kwakjungwon studyofquantitativeindicatorsforslicesortingincinemode4dct