Cargando…

Fine tuning and optimization of magnetic hyperthermia treatments using versatile trapezoidal driving-field waveforms

Applying trapezoidal driving-field waveforms to activate magnetic nanoparticles optimizes their performance as heat generators in magnetic hyperthermia, with notable advantages with respect to the effects of harmonic magnetic fields of the same frequency and amplitude. A rate equation approach is us...

Descripción completa

Detalles Bibliográficos
Autores principales: Barrera, Gabriele, Allia, Paolo, Tiberto, Paola
Formato: Online Artículo Texto
Lenguaje:English
Publicado: RSC 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9417573/
https://www.ncbi.nlm.nih.gov/pubmed/36132915
http://dx.doi.org/10.1039/d0na00358a
_version_ 1784776748612714496
author Barrera, Gabriele
Allia, Paolo
Tiberto, Paola
author_facet Barrera, Gabriele
Allia, Paolo
Tiberto, Paola
author_sort Barrera, Gabriele
collection PubMed
description Applying trapezoidal driving-field waveforms to activate magnetic nanoparticles optimizes their performance as heat generators in magnetic hyperthermia, with notable advantages with respect to the effects of harmonic magnetic fields of the same frequency and amplitude. A rate equation approach is used to determine the hysteretic properties and the power released by monodisperse and polydisperse magnetite nanoparticles with randomly oriented easy axes subjected to a radio-frequency trapezoidal driving field. The heating ability of the activated nanoparticles is investigated by means of a simple model in which the heat equation is solved in radial geometry with boundary conditions simulating in vivo applications. Changes of the inclination of the trapezoidal waveform's lateral sides are shown to induce controlled changes in the specific loss power generated by the activated nanoparticles. Specific issues typical of the therapeutic practice of hyperthermia, such as the need for fine tuning of the optimal treatment temperature in real time, the possibility of combining sequential treatments at different temperatures, and the ability to substantially reduce the heating transient in a hyperthermia treatment are suitably addressed and overcome by making use of versatile driving fields of a trapezoidal shape.
format Online
Article
Text
id pubmed-9417573
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher RSC
record_format MEDLINE/PubMed
spelling pubmed-94175732022-09-20 Fine tuning and optimization of magnetic hyperthermia treatments using versatile trapezoidal driving-field waveforms Barrera, Gabriele Allia, Paolo Tiberto, Paola Nanoscale Adv Chemistry Applying trapezoidal driving-field waveforms to activate magnetic nanoparticles optimizes their performance as heat generators in magnetic hyperthermia, with notable advantages with respect to the effects of harmonic magnetic fields of the same frequency and amplitude. A rate equation approach is used to determine the hysteretic properties and the power released by monodisperse and polydisperse magnetite nanoparticles with randomly oriented easy axes subjected to a radio-frequency trapezoidal driving field. The heating ability of the activated nanoparticles is investigated by means of a simple model in which the heat equation is solved in radial geometry with boundary conditions simulating in vivo applications. Changes of the inclination of the trapezoidal waveform's lateral sides are shown to induce controlled changes in the specific loss power generated by the activated nanoparticles. Specific issues typical of the therapeutic practice of hyperthermia, such as the need for fine tuning of the optimal treatment temperature in real time, the possibility of combining sequential treatments at different temperatures, and the ability to substantially reduce the heating transient in a hyperthermia treatment are suitably addressed and overcome by making use of versatile driving fields of a trapezoidal shape. RSC 2020-09-01 /pmc/articles/PMC9417573/ /pubmed/36132915 http://dx.doi.org/10.1039/d0na00358a Text en This journal is © The Royal Society of Chemistry https://creativecommons.org/licenses/by/3.0/
spellingShingle Chemistry
Barrera, Gabriele
Allia, Paolo
Tiberto, Paola
Fine tuning and optimization of magnetic hyperthermia treatments using versatile trapezoidal driving-field waveforms
title Fine tuning and optimization of magnetic hyperthermia treatments using versatile trapezoidal driving-field waveforms
title_full Fine tuning and optimization of magnetic hyperthermia treatments using versatile trapezoidal driving-field waveforms
title_fullStr Fine tuning and optimization of magnetic hyperthermia treatments using versatile trapezoidal driving-field waveforms
title_full_unstemmed Fine tuning and optimization of magnetic hyperthermia treatments using versatile trapezoidal driving-field waveforms
title_short Fine tuning and optimization of magnetic hyperthermia treatments using versatile trapezoidal driving-field waveforms
title_sort fine tuning and optimization of magnetic hyperthermia treatments using versatile trapezoidal driving-field waveforms
topic Chemistry
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9417573/
https://www.ncbi.nlm.nih.gov/pubmed/36132915
http://dx.doi.org/10.1039/d0na00358a
work_keys_str_mv AT barreragabriele finetuningandoptimizationofmagnetichyperthermiatreatmentsusingversatiletrapezoidaldrivingfieldwaveforms
AT alliapaolo finetuningandoptimizationofmagnetichyperthermiatreatmentsusingversatiletrapezoidaldrivingfieldwaveforms
AT tibertopaola finetuningandoptimizationofmagnetichyperthermiatreatmentsusingversatiletrapezoidaldrivingfieldwaveforms