Cargando…

Evaluation of corneal hysteresis after pars plana vitrectomy combined phacoemulsification and intraocular lens implantation

We evaluated the early effects of pars plana vitrectomy (PPV) on corneal biomechanics by comparing corneal hysteresis (CH) after cataract surgery (phacoemulsification and aspiration with intraocular lens implantation; PEA + IOL) alone and PPV combined with cataract surgery. This study included 20 ey...

Descripción completa

Detalles Bibliográficos
Autores principales: Ohta, Manami, Wakuta, Makiko, Sakuma, Ayano, Hasegawa, Mina, Hamada, Waka, Higashijima, Fumiaki, Yoshimoto, Takuya, Ogata, Tadahiko, Kobayashi, Yuka, Kimura, Kazuhiro
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9418308/
https://www.ncbi.nlm.nih.gov/pubmed/36028519
http://dx.doi.org/10.1038/s41598-022-18299-1
_version_ 1784776920396726272
author Ohta, Manami
Wakuta, Makiko
Sakuma, Ayano
Hasegawa, Mina
Hamada, Waka
Higashijima, Fumiaki
Yoshimoto, Takuya
Ogata, Tadahiko
Kobayashi, Yuka
Kimura, Kazuhiro
author_facet Ohta, Manami
Wakuta, Makiko
Sakuma, Ayano
Hasegawa, Mina
Hamada, Waka
Higashijima, Fumiaki
Yoshimoto, Takuya
Ogata, Tadahiko
Kobayashi, Yuka
Kimura, Kazuhiro
author_sort Ohta, Manami
collection PubMed
description We evaluated the early effects of pars plana vitrectomy (PPV) on corneal biomechanics by comparing corneal hysteresis (CH) after cataract surgery (phacoemulsification and aspiration with intraocular lens implantation; PEA + IOL) alone and PPV combined with cataract surgery. This study included 20 eyes (18 patients), who underwent cataract surgery alone (PEA + IOL group), and 28 eyes (27 patients) who underwent PPV combined with cataract surgery (PPV triple group). The CH was 11.1 ± 1.1, 10.4 ± 1.1, and 11.0 ± 1.0 mmHg in the PEA + IOL group and 11.0 ± 1.4, 9.8 ± 1.4, and 10.6 ± 1.6 mmHg in the PPV triple group, preoperatively, at 2 weeks, and 3 months after surgery, respectively. The CH was not significantly different after surgery in the PEA + IOL group, but decreased significantly in the PPV triple group 2 weeks following surgery (p < 0.01). Intraocular pressure (IOP) and central corneal thickness (CCT) did not change significantly after surgery in either group. Preoperatively, there was a positive correlation between CH and CCT in the PPV triple group, but the correlation disappeared postoperatively. In PPV combined with cataract surgery, CH temporarily decreased postoperatively, independent of IOP and CCT. Removal of the vitreous may reduce the elasticity and rigidity of the entire eye.
format Online
Article
Text
id pubmed-9418308
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-94183082022-08-28 Evaluation of corneal hysteresis after pars plana vitrectomy combined phacoemulsification and intraocular lens implantation Ohta, Manami Wakuta, Makiko Sakuma, Ayano Hasegawa, Mina Hamada, Waka Higashijima, Fumiaki Yoshimoto, Takuya Ogata, Tadahiko Kobayashi, Yuka Kimura, Kazuhiro Sci Rep Article We evaluated the early effects of pars plana vitrectomy (PPV) on corneal biomechanics by comparing corneal hysteresis (CH) after cataract surgery (phacoemulsification and aspiration with intraocular lens implantation; PEA + IOL) alone and PPV combined with cataract surgery. This study included 20 eyes (18 patients), who underwent cataract surgery alone (PEA + IOL group), and 28 eyes (27 patients) who underwent PPV combined with cataract surgery (PPV triple group). The CH was 11.1 ± 1.1, 10.4 ± 1.1, and 11.0 ± 1.0 mmHg in the PEA + IOL group and 11.0 ± 1.4, 9.8 ± 1.4, and 10.6 ± 1.6 mmHg in the PPV triple group, preoperatively, at 2 weeks, and 3 months after surgery, respectively. The CH was not significantly different after surgery in the PEA + IOL group, but decreased significantly in the PPV triple group 2 weeks following surgery (p < 0.01). Intraocular pressure (IOP) and central corneal thickness (CCT) did not change significantly after surgery in either group. Preoperatively, there was a positive correlation between CH and CCT in the PPV triple group, but the correlation disappeared postoperatively. In PPV combined with cataract surgery, CH temporarily decreased postoperatively, independent of IOP and CCT. Removal of the vitreous may reduce the elasticity and rigidity of the entire eye. Nature Publishing Group UK 2022-08-26 /pmc/articles/PMC9418308/ /pubmed/36028519 http://dx.doi.org/10.1038/s41598-022-18299-1 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Article
Ohta, Manami
Wakuta, Makiko
Sakuma, Ayano
Hasegawa, Mina
Hamada, Waka
Higashijima, Fumiaki
Yoshimoto, Takuya
Ogata, Tadahiko
Kobayashi, Yuka
Kimura, Kazuhiro
Evaluation of corneal hysteresis after pars plana vitrectomy combined phacoemulsification and intraocular lens implantation
title Evaluation of corneal hysteresis after pars plana vitrectomy combined phacoemulsification and intraocular lens implantation
title_full Evaluation of corneal hysteresis after pars plana vitrectomy combined phacoemulsification and intraocular lens implantation
title_fullStr Evaluation of corneal hysteresis after pars plana vitrectomy combined phacoemulsification and intraocular lens implantation
title_full_unstemmed Evaluation of corneal hysteresis after pars plana vitrectomy combined phacoemulsification and intraocular lens implantation
title_short Evaluation of corneal hysteresis after pars plana vitrectomy combined phacoemulsification and intraocular lens implantation
title_sort evaluation of corneal hysteresis after pars plana vitrectomy combined phacoemulsification and intraocular lens implantation
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9418308/
https://www.ncbi.nlm.nih.gov/pubmed/36028519
http://dx.doi.org/10.1038/s41598-022-18299-1
work_keys_str_mv AT ohtamanami evaluationofcornealhysteresisafterparsplanavitrectomycombinedphacoemulsificationandintraocularlensimplantation
AT wakutamakiko evaluationofcornealhysteresisafterparsplanavitrectomycombinedphacoemulsificationandintraocularlensimplantation
AT sakumaayano evaluationofcornealhysteresisafterparsplanavitrectomycombinedphacoemulsificationandintraocularlensimplantation
AT hasegawamina evaluationofcornealhysteresisafterparsplanavitrectomycombinedphacoemulsificationandintraocularlensimplantation
AT hamadawaka evaluationofcornealhysteresisafterparsplanavitrectomycombinedphacoemulsificationandintraocularlensimplantation
AT higashijimafumiaki evaluationofcornealhysteresisafterparsplanavitrectomycombinedphacoemulsificationandintraocularlensimplantation
AT yoshimototakuya evaluationofcornealhysteresisafterparsplanavitrectomycombinedphacoemulsificationandintraocularlensimplantation
AT ogatatadahiko evaluationofcornealhysteresisafterparsplanavitrectomycombinedphacoemulsificationandintraocularlensimplantation
AT kobayashiyuka evaluationofcornealhysteresisafterparsplanavitrectomycombinedphacoemulsificationandintraocularlensimplantation
AT kimurakazuhiro evaluationofcornealhysteresisafterparsplanavitrectomycombinedphacoemulsificationandintraocularlensimplantation