Cargando…

Establishment of Reference Intervals for Serum Protein Electrophoresis of Apparently Healthy Adults in Addis Ababa, Ethiopia

BACKGROUND: Even though several factors affect reference intervals (RIs), company-derived values are currently in use in many laboratories worldwide. However, few or no data are available regarding serum proteins RIs, especially in resource-limited countries such as Ethiopia. OBJECTIVE: To establish...

Descripción completa

Detalles Bibliográficos
Autores principales: Bikila, Demiraw, Lejisa, Tadesse, Tolcha, Yosef, Bashea, Chala, Meles, Mehari, Getahun, Tigist, Ashebir, Genet, Habtu, Wossene, Challa, Feyissa, Mohammed, Ousman, Kassaw, Melkitu, Kebede, Adisu, G/Egzeabher, Letebrhan, Befekadu, Endalkachew, Wolde, Mistire, Tsegaye, Aster
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9419900/
https://www.ncbi.nlm.nih.gov/pubmed/36039308
http://dx.doi.org/10.2147/IJGM.S376450
Descripción
Sumario:BACKGROUND: Even though several factors affect reference intervals (RIs), company-derived values are currently in use in many laboratories worldwide. However, few or no data are available regarding serum proteins RIs, especially in resource-limited countries such as Ethiopia. OBJECTIVE: To establish RIs for serum protein electrophoresis of apparently healthy adults in Addis Ababa, Ethiopia. METHODS: A cross-sectional study was conducted on a total of 297 apparently healthy adults from April to October 2019 in four selected sub-cities (Akaki, Kirkos, Arada, and Yeka) of Addis Ababa, Ethiopia. Laboratory analysis of collected samples was performed using the Capillarys 2 Flex Piercing analyzer, while statistical analysis was conducted using SPSS version 23 and Med-Calc software. The Mann–Whitney test was used to check partitions. A non-parametric method of reference range establishment was performed as per CLSI guideline EP28A3C. RESULTS: The established RIs were: albumin 53.83–64.59%, 52.24–63.55%; alpha-1 globulin 3.04–5.40%, 3.44–5.60%; alpha-2 globulin 8.0–12.67%, 8.44–12.87%; and beta-1 globulin 5.01–7.38%, 5.14–7.86%. Moreover, the albumin to globulin ratios were 1.16–1.8 and 1.09–1.74 for males and females, respectively. The combined RIs for beta-2 globulin and gamma globulin were 2.54–4.90% and 12.40–21.66%, respectively. CONCLUSION: The established reference interval for serum protein fractions revealed gender-specific differences, except for beta-2 globulin and gamma globulin.