DOAC Dipstick Testing Can Reliably Exclude the Presence of Clinically Relevant DOAC Concentrations in Circulation
In certain clinical situations, it is necessary to determine whether clinically relevant plasma levels of direct oral anticoagulants (DOACs) are present. We examined whether qualitative testing of DOACs in urine samples can exclude DOAC plasma concentrations of ≥30 ng/mL. This prospective single-cen...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Georg Thieme Verlag KG
2022
|
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9420550/ https://www.ncbi.nlm.nih.gov/pubmed/35088395 http://dx.doi.org/10.1055/a-1753-2748 |
_version_ | 1784777415368638464 |
---|---|
author | Margetić, Sandra Ćelap, Ivana Huzjan, Arijana Lovrenčić Puretić, Marijana Bosnar Goreta, Sandra Šupraha Glojnarić, Anesa Čajević Brkljačić, Diana Delić Mioč, Pavao Harenberg, Job Hetjens, Svetlana Weiss, Christel |
author_facet | Margetić, Sandra Ćelap, Ivana Huzjan, Arijana Lovrenčić Puretić, Marijana Bosnar Goreta, Sandra Šupraha Glojnarić, Anesa Čajević Brkljačić, Diana Delić Mioč, Pavao Harenberg, Job Hetjens, Svetlana Weiss, Christel |
author_sort | Margetić, Sandra |
collection | PubMed |
description | In certain clinical situations, it is necessary to determine whether clinically relevant plasma levels of direct oral anticoagulants (DOACs) are present. We examined whether qualitative testing of DOACs in urine samples can exclude DOAC plasma concentrations of ≥30 ng/mL. This prospective single-center cohort study included consecutive patients treated with an oral direct factor Xa inhibitor (DXI) (apixaban, n = 31, rivaroxaban, n = 53) and direct thrombin inhibitor (DTI) (dabigatran, n = 44). We aimed to define the negative predictive value (NPV) and other statistical parameters of detecting DXIs and DTIs by DOAC Dipstick at plasma concentrations of ≥30 ng/mL. We also determined the best-fit threshold plasma levels using chromogenic substrate assays by logistic regression analysis. Between July 2020 and July 2021, 128 eligible patients (mean age 66 years, 55 females) were included into the study. The NPVs and sensitivities for DXI and DTI of DOAC Dipstick were 100% at ≥30 ng/mL plasma, for specificities 6 and 21% and for positive predictive values 62 and 72%, respectively. All diagnostic statistical tests improved to values between 86 and 100% at best-fitting plasma thresholds of ≥14 ng/mL for DXI and ≥19 ng/mL for DTI. Visual analysis using the DOAC Dipstick was 100% in agreement with that of the optoelectronic DOASENSE Reader for all the three DOACs. DOAC Dipstick testing can reliably exclude the presence of DOACs in urine samples at best-fitting thresholds of >14 and >19 ng/mL in plasma. The performance of the DOAC Dipstick at detecting lower DOAC concentrations in plasma requires confirmation. |
format | Online Article Text |
id | pubmed-9420550 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Georg Thieme Verlag KG |
record_format | MEDLINE/PubMed |
spelling | pubmed-94205502022-08-29 DOAC Dipstick Testing Can Reliably Exclude the Presence of Clinically Relevant DOAC Concentrations in Circulation Margetić, Sandra Ćelap, Ivana Huzjan, Arijana Lovrenčić Puretić, Marijana Bosnar Goreta, Sandra Šupraha Glojnarić, Anesa Čajević Brkljačić, Diana Delić Mioč, Pavao Harenberg, Job Hetjens, Svetlana Weiss, Christel Thromb Haemost In certain clinical situations, it is necessary to determine whether clinically relevant plasma levels of direct oral anticoagulants (DOACs) are present. We examined whether qualitative testing of DOACs in urine samples can exclude DOAC plasma concentrations of ≥30 ng/mL. This prospective single-center cohort study included consecutive patients treated with an oral direct factor Xa inhibitor (DXI) (apixaban, n = 31, rivaroxaban, n = 53) and direct thrombin inhibitor (DTI) (dabigatran, n = 44). We aimed to define the negative predictive value (NPV) and other statistical parameters of detecting DXIs and DTIs by DOAC Dipstick at plasma concentrations of ≥30 ng/mL. We also determined the best-fit threshold plasma levels using chromogenic substrate assays by logistic regression analysis. Between July 2020 and July 2021, 128 eligible patients (mean age 66 years, 55 females) were included into the study. The NPVs and sensitivities for DXI and DTI of DOAC Dipstick were 100% at ≥30 ng/mL plasma, for specificities 6 and 21% and for positive predictive values 62 and 72%, respectively. All diagnostic statistical tests improved to values between 86 and 100% at best-fitting plasma thresholds of ≥14 ng/mL for DXI and ≥19 ng/mL for DTI. Visual analysis using the DOAC Dipstick was 100% in agreement with that of the optoelectronic DOASENSE Reader for all the three DOACs. DOAC Dipstick testing can reliably exclude the presence of DOACs in urine samples at best-fitting thresholds of >14 and >19 ng/mL in plasma. The performance of the DOAC Dipstick at detecting lower DOAC concentrations in plasma requires confirmation. Georg Thieme Verlag KG 2022-03-10 /pmc/articles/PMC9420550/ /pubmed/35088395 http://dx.doi.org/10.1055/a-1753-2748 Text en Thieme. All rights reserved. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives License, which permits unrestricted reproduction and distribution, for non-commercial purposes only; and use and reproduction, but not distribution, of adapted material for non-commercial purposes only, provided the original work is properly cited. |
spellingShingle | Margetić, Sandra Ćelap, Ivana Huzjan, Arijana Lovrenčić Puretić, Marijana Bosnar Goreta, Sandra Šupraha Glojnarić, Anesa Čajević Brkljačić, Diana Delić Mioč, Pavao Harenberg, Job Hetjens, Svetlana Weiss, Christel DOAC Dipstick Testing Can Reliably Exclude the Presence of Clinically Relevant DOAC Concentrations in Circulation |
title | DOAC Dipstick Testing Can Reliably Exclude the Presence of Clinically Relevant DOAC Concentrations in Circulation |
title_full | DOAC Dipstick Testing Can Reliably Exclude the Presence of Clinically Relevant DOAC Concentrations in Circulation |
title_fullStr | DOAC Dipstick Testing Can Reliably Exclude the Presence of Clinically Relevant DOAC Concentrations in Circulation |
title_full_unstemmed | DOAC Dipstick Testing Can Reliably Exclude the Presence of Clinically Relevant DOAC Concentrations in Circulation |
title_short | DOAC Dipstick Testing Can Reliably Exclude the Presence of Clinically Relevant DOAC Concentrations in Circulation |
title_sort | doac dipstick testing can reliably exclude the presence of clinically relevant doac concentrations in circulation |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9420550/ https://www.ncbi.nlm.nih.gov/pubmed/35088395 http://dx.doi.org/10.1055/a-1753-2748 |
work_keys_str_mv | AT margeticsandra doacdipsticktestingcanreliablyexcludethepresenceofclinicallyrelevantdoacconcentrationsincirculation AT celapivana doacdipsticktestingcanreliablyexcludethepresenceofclinicallyrelevantdoacconcentrationsincirculation AT huzjanarijanalovrencic doacdipsticktestingcanreliablyexcludethepresenceofclinicallyrelevantdoacconcentrationsincirculation AT pureticmarijanabosnar doacdipsticktestingcanreliablyexcludethepresenceofclinicallyrelevantdoacconcentrationsincirculation AT goretasandrasupraha doacdipsticktestingcanreliablyexcludethepresenceofclinicallyrelevantdoacconcentrationsincirculation AT glojnaricanesacajevic doacdipsticktestingcanreliablyexcludethepresenceofclinicallyrelevantdoacconcentrationsincirculation AT brkljacicdianadelic doacdipsticktestingcanreliablyexcludethepresenceofclinicallyrelevantdoacconcentrationsincirculation AT miocpavao doacdipsticktestingcanreliablyexcludethepresenceofclinicallyrelevantdoacconcentrationsincirculation AT harenbergjob doacdipsticktestingcanreliablyexcludethepresenceofclinicallyrelevantdoacconcentrationsincirculation AT hetjenssvetlana doacdipsticktestingcanreliablyexcludethepresenceofclinicallyrelevantdoacconcentrationsincirculation AT weisschristel doacdipsticktestingcanreliablyexcludethepresenceofclinicallyrelevantdoacconcentrationsincirculation |