Cargando…

Applicability of the real ear measurement for audiological intervention of tinnitus()()

INTRODUCTION: Tinnitus is present in a large part of chronic health complaints, and it is considered a public health problem injurious to the individual's quality of life. Considering the increase of the world population associated with an increase of life expectancy, tinnitus remains a cause f...

Descripción completa

Detalles Bibliográficos
Autores principales: Rocha, Andressa Vital, Mondelli, Maria Fernanda Capoani Garcia
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9422393/
https://www.ncbi.nlm.nih.gov/pubmed/30337103
http://dx.doi.org/10.1016/j.bjorl.2018.07.010
_version_ 1784777801685008384
author Rocha, Andressa Vital
Mondelli, Maria Fernanda Capoani Garcia
author_facet Rocha, Andressa Vital
Mondelli, Maria Fernanda Capoani Garcia
author_sort Rocha, Andressa Vital
collection PubMed
description INTRODUCTION: Tinnitus is present in a large part of chronic health complaints, and it is considered a public health problem injurious to the individual's quality of life. Considering the increase of the world population associated with an increase of life expectancy, tinnitus remains a cause for medical concern, since during aging the occurrence of auditory impairments due to the deterioration of the peripheral auditory structures and central impairs the quality of life. OBJECTIVE: The aim of the present study was to analyze the applicability of real ear measurements for audiological intervention of tinnitus through specific evaluation, selection, verification and validation of the hearing aids combined with the sound generator. METHODS: Forty individuals of both genders with hearing loss and tinnitus complaints were deemed eligible to compose the sample. They were enrolled according to clinical symptoms and submitted to the following procedures: anamnesis and previous complaint history, high frequency audiometry, immittanciometry and acuphenometry with the research of psychoacoustic thresholds of pitch, loudness and minimum masking threshold, sound generator, in addition to the application of the Tinnitus Handicap Inventory and Visual Analog Scale tools. The entire sample was adapted with Siemens hearing aids and a sound generator, participated in a counseling session with support of digital material and evaluated in two situations: Initial Assessment (before the hearing aids and sound generator adaptation) and Final Assessment (6 months, after adaptation). The statistical analyzes were descriptive and inferential, adopted a significance level of 5% and the T-Paired Test and the Spearman Correlation test were performed. RESULTS: The results showed that there was a benefit with the use of hearing aids combined with a sound generator from the statistically significant values and strong correlations between the sound generator verification data regarding acuphenometry and the nuisance/severity questionnaires. Regarding the verification of the sound generator, it is important to highlight that the entire sample selected the effective acoustic stimulation based on the comfort levels, which was proved in the present study to be a sufficient intensity for positive prognosis, whereas the users’ noises were found below the psychoacoustic thresholds of acuphenometry. CONCLUSION: The present study concluded that the audiological intervention with any level of sound stimulus is enough to obtain a positive prognosis in the medium term. Data that specifies that the verification of sound generator was effective at the real ear measurements are important in the evaluation and intervention of the complaint. In addition, it points out that the greater the tinnitus perception, the greater its severity, and the greater the nuisance, the higher the psychoacoustics thresholds of frequency and the minimum threshold of masking.
format Online
Article
Text
id pubmed-9422393
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-94223932022-08-31 Applicability of the real ear measurement for audiological intervention of tinnitus()() Rocha, Andressa Vital Mondelli, Maria Fernanda Capoani Garcia Braz J Otorhinolaryngol Original Article INTRODUCTION: Tinnitus is present in a large part of chronic health complaints, and it is considered a public health problem injurious to the individual's quality of life. Considering the increase of the world population associated with an increase of life expectancy, tinnitus remains a cause for medical concern, since during aging the occurrence of auditory impairments due to the deterioration of the peripheral auditory structures and central impairs the quality of life. OBJECTIVE: The aim of the present study was to analyze the applicability of real ear measurements for audiological intervention of tinnitus through specific evaluation, selection, verification and validation of the hearing aids combined with the sound generator. METHODS: Forty individuals of both genders with hearing loss and tinnitus complaints were deemed eligible to compose the sample. They were enrolled according to clinical symptoms and submitted to the following procedures: anamnesis and previous complaint history, high frequency audiometry, immittanciometry and acuphenometry with the research of psychoacoustic thresholds of pitch, loudness and minimum masking threshold, sound generator, in addition to the application of the Tinnitus Handicap Inventory and Visual Analog Scale tools. The entire sample was adapted with Siemens hearing aids and a sound generator, participated in a counseling session with support of digital material and evaluated in two situations: Initial Assessment (before the hearing aids and sound generator adaptation) and Final Assessment (6 months, after adaptation). The statistical analyzes were descriptive and inferential, adopted a significance level of 5% and the T-Paired Test and the Spearman Correlation test were performed. RESULTS: The results showed that there was a benefit with the use of hearing aids combined with a sound generator from the statistically significant values and strong correlations between the sound generator verification data regarding acuphenometry and the nuisance/severity questionnaires. Regarding the verification of the sound generator, it is important to highlight that the entire sample selected the effective acoustic stimulation based on the comfort levels, which was proved in the present study to be a sufficient intensity for positive prognosis, whereas the users’ noises were found below the psychoacoustic thresholds of acuphenometry. CONCLUSION: The present study concluded that the audiological intervention with any level of sound stimulus is enough to obtain a positive prognosis in the medium term. Data that specifies that the verification of sound generator was effective at the real ear measurements are important in the evaluation and intervention of the complaint. In addition, it points out that the greater the tinnitus perception, the greater its severity, and the greater the nuisance, the higher the psychoacoustics thresholds of frequency and the minimum threshold of masking. Elsevier 2018-08-23 /pmc/articles/PMC9422393/ /pubmed/30337103 http://dx.doi.org/10.1016/j.bjorl.2018.07.010 Text en © 2018 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Original Article
Rocha, Andressa Vital
Mondelli, Maria Fernanda Capoani Garcia
Applicability of the real ear measurement for audiological intervention of tinnitus()()
title Applicability of the real ear measurement for audiological intervention of tinnitus()()
title_full Applicability of the real ear measurement for audiological intervention of tinnitus()()
title_fullStr Applicability of the real ear measurement for audiological intervention of tinnitus()()
title_full_unstemmed Applicability of the real ear measurement for audiological intervention of tinnitus()()
title_short Applicability of the real ear measurement for audiological intervention of tinnitus()()
title_sort applicability of the real ear measurement for audiological intervention of tinnitus()()
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9422393/
https://www.ncbi.nlm.nih.gov/pubmed/30337103
http://dx.doi.org/10.1016/j.bjorl.2018.07.010
work_keys_str_mv AT rochaandressavital applicabilityoftherealearmeasurementforaudiologicalinterventionoftinnitus
AT mondellimariafernandacapoanigarcia applicabilityoftherealearmeasurementforaudiologicalinterventionoftinnitus