Cargando…

Validation of the Modena bleeding score in endoscopic sinus surgery

INTRODUCTION: The Modena bleeding score is a categorical rating scale that allows the assessment of the surgical field in relation to bleeding during endoscopic surgery. It has recently been presented and validated in the field of endoscopic ear surgery by the present authors. The Modena bleeding sc...

Descripción completa

Detalles Bibliográficos
Autores principales: Alicandri-Ciufelli, Matteo, Pingani, Luca, Maccarrone, Francesco, Anschuetz, Lukas, Mariano, Davide, Galeazzi, Gian Maria, Presutti, Livio, Molinari, Giulia
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9422547/
https://www.ncbi.nlm.nih.gov/pubmed/33279423
http://dx.doi.org/10.1016/j.bjorl.2020.08.006
_version_ 1784777838043332608
author Alicandri-Ciufelli, Matteo
Pingani, Luca
Maccarrone, Francesco
Anschuetz, Lukas
Mariano, Davide
Galeazzi, Gian Maria
Presutti, Livio
Molinari, Giulia
author_facet Alicandri-Ciufelli, Matteo
Pingani, Luca
Maccarrone, Francesco
Anschuetz, Lukas
Mariano, Davide
Galeazzi, Gian Maria
Presutti, Livio
Molinari, Giulia
author_sort Alicandri-Ciufelli, Matteo
collection PubMed
description INTRODUCTION: The Modena bleeding score is a categorical rating scale that allows the assessment of the surgical field in relation to bleeding during endoscopic surgery. It has recently been presented and validated in the field of endoscopic ear surgery by the present authors. The Modena bleeding score provides five grades for rating the surgical field during endoscopic procedures (from grade 1 − no bleeding to grade 5 − bleeding that prevents every surgical procedure except those dedicated to bleeding control). OBJECTIVE: The aim of this study was to validate the Modena bleeding score in the setting of endoscopic sinus surgery. METHODS: Fifteen three-minute videos of endoscopic sinus surgery procedures (each containing three bleeding situations) were evaluated by 15 specialists, using the Modena bleeding score. Intra and inter-rater reliability were assessed, and the clinical validity of the Modena bleeding score was calculated using a referent standard. RESULTS: The data analysis showed an intra-rater reliability ranging from 0.6336 to 0.861. The inter-rater reliability ranged from 0.676 to 0.844. The clinical validity was α = 0.70; confidence limits: 0.64 − 0.75, corresponding to substantial agreement. CONCLUSION: The Modena bleeding score is an effective method to score bleeding during endoscopic sinus surgery. Its application in future research could facilitate the performance and efficacy assessment of surgical techniques, materials or devices aimed to bleeding control during endoscopic sinus surgery.
format Online
Article
Text
id pubmed-9422547
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-94225472022-08-31 Validation of the Modena bleeding score in endoscopic sinus surgery Alicandri-Ciufelli, Matteo Pingani, Luca Maccarrone, Francesco Anschuetz, Lukas Mariano, Davide Galeazzi, Gian Maria Presutti, Livio Molinari, Giulia Braz J Otorhinolaryngol Original Article INTRODUCTION: The Modena bleeding score is a categorical rating scale that allows the assessment of the surgical field in relation to bleeding during endoscopic surgery. It has recently been presented and validated in the field of endoscopic ear surgery by the present authors. The Modena bleeding score provides five grades for rating the surgical field during endoscopic procedures (from grade 1 − no bleeding to grade 5 − bleeding that prevents every surgical procedure except those dedicated to bleeding control). OBJECTIVE: The aim of this study was to validate the Modena bleeding score in the setting of endoscopic sinus surgery. METHODS: Fifteen three-minute videos of endoscopic sinus surgery procedures (each containing three bleeding situations) were evaluated by 15 specialists, using the Modena bleeding score. Intra and inter-rater reliability were assessed, and the clinical validity of the Modena bleeding score was calculated using a referent standard. RESULTS: The data analysis showed an intra-rater reliability ranging from 0.6336 to 0.861. The inter-rater reliability ranged from 0.676 to 0.844. The clinical validity was α = 0.70; confidence limits: 0.64 − 0.75, corresponding to substantial agreement. CONCLUSION: The Modena bleeding score is an effective method to score bleeding during endoscopic sinus surgery. Its application in future research could facilitate the performance and efficacy assessment of surgical techniques, materials or devices aimed to bleeding control during endoscopic sinus surgery. Elsevier 2020-09-30 /pmc/articles/PMC9422547/ /pubmed/33279423 http://dx.doi.org/10.1016/j.bjorl.2020.08.006 Text en © 2020 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Original Article
Alicandri-Ciufelli, Matteo
Pingani, Luca
Maccarrone, Francesco
Anschuetz, Lukas
Mariano, Davide
Galeazzi, Gian Maria
Presutti, Livio
Molinari, Giulia
Validation of the Modena bleeding score in endoscopic sinus surgery
title Validation of the Modena bleeding score in endoscopic sinus surgery
title_full Validation of the Modena bleeding score in endoscopic sinus surgery
title_fullStr Validation of the Modena bleeding score in endoscopic sinus surgery
title_full_unstemmed Validation of the Modena bleeding score in endoscopic sinus surgery
title_short Validation of the Modena bleeding score in endoscopic sinus surgery
title_sort validation of the modena bleeding score in endoscopic sinus surgery
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9422547/
https://www.ncbi.nlm.nih.gov/pubmed/33279423
http://dx.doi.org/10.1016/j.bjorl.2020.08.006
work_keys_str_mv AT alicandriciufellimatteo validationofthemodenableedingscoreinendoscopicsinussurgery
AT pinganiluca validationofthemodenableedingscoreinendoscopicsinussurgery
AT maccarronefrancesco validationofthemodenableedingscoreinendoscopicsinussurgery
AT anschuetzlukas validationofthemodenableedingscoreinendoscopicsinussurgery
AT marianodavide validationofthemodenableedingscoreinendoscopicsinussurgery
AT galeazzigianmaria validationofthemodenableedingscoreinendoscopicsinussurgery
AT presuttilivio validationofthemodenableedingscoreinendoscopicsinussurgery
AT molinarigiulia validationofthemodenableedingscoreinendoscopicsinussurgery