Polyethylene terephthalate clamps: Optimization in endodontic and restorative practices
BACKGROUND: There is a growing search for innovations in dental materials and instruments and, therefore, an increase need to optimize the instruments used in the absolute isolation. The gold standard procedure contributes significantly to the quality of restorative and endodontic procedures. Thus,...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medicina Oral S.L.
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9422974/ https://www.ncbi.nlm.nih.gov/pubmed/36046164 http://dx.doi.org/10.4317/jced.59603 |
_version_ | 1784777928113913856 |
---|---|
author | Ferreira e Cunha, Anna-Flávia Madalena, Isabela-Ribeiro Küchler, Erika-Calvano Pereira, Tiago-Lima Honorato, Richard de Menezes, Fernando-Carlos-Hueb Lepri, César-Penazzo Oliveira, Maria-Angélica-Hueb-de Menezes |
author_facet | Ferreira e Cunha, Anna-Flávia Madalena, Isabela-Ribeiro Küchler, Erika-Calvano Pereira, Tiago-Lima Honorato, Richard de Menezes, Fernando-Carlos-Hueb Lepri, César-Penazzo Oliveira, Maria-Angélica-Hueb-de Menezes |
author_sort | Ferreira e Cunha, Anna-Flávia |
collection | PubMed |
description | BACKGROUND: There is a growing search for innovations in dental materials and instruments and, therefore, an increase need to optimize the instruments used in the absolute isolation. The gold standard procedure contributes significantly to the quality of restorative and endodontic procedures. Thus, the aim of the present study was to evaluate the radiopacity of polyethylene terephthalate polymer clamps and compare them to conventional metal clamps. MATERIAL AND METHODS: The polyethylene terephthalate clamp was developed at the University of Uberaba (Patent application #PI0901719-4, Uberaba, MG, Brazil). Five polyethylene terephthalate clamps and five conventional metal clamps were used. The clamps were positioned, next to an aluminum scale, under the same phosphor plate to perform 3 radiographs. The locator cylinder was set perpendicular to the radiographic films at a focal length of 20 cm and set to 60 kVp and 0.06 seconds. After image processing, optical density values were read using DBWin 5.0.4 software. The mean of the 3 readings taken on each clamp was adopted as the radiodensity of the specimen. The differences between the groups were compared using Student’s t-test (p<0.05). RESULTS: Polyethylene terephthalate clamps demonstrated significantly lower radiopacity than conventional metal clamps (p<0.05). CONCLUSIONS: Polyethylene terephthalate clamps have lower radiopacity when compared to conventional metal clamps. Key words:Rubber Dams, Dentistry, Operative, Endodontics. |
format | Online Article Text |
id | pubmed-9422974 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Medicina Oral S.L. |
record_format | MEDLINE/PubMed |
spelling | pubmed-94229742022-08-30 Polyethylene terephthalate clamps: Optimization in endodontic and restorative practices Ferreira e Cunha, Anna-Flávia Madalena, Isabela-Ribeiro Küchler, Erika-Calvano Pereira, Tiago-Lima Honorato, Richard de Menezes, Fernando-Carlos-Hueb Lepri, César-Penazzo Oliveira, Maria-Angélica-Hueb-de Menezes J Clin Exp Dent Research BACKGROUND: There is a growing search for innovations in dental materials and instruments and, therefore, an increase need to optimize the instruments used in the absolute isolation. The gold standard procedure contributes significantly to the quality of restorative and endodontic procedures. Thus, the aim of the present study was to evaluate the radiopacity of polyethylene terephthalate polymer clamps and compare them to conventional metal clamps. MATERIAL AND METHODS: The polyethylene terephthalate clamp was developed at the University of Uberaba (Patent application #PI0901719-4, Uberaba, MG, Brazil). Five polyethylene terephthalate clamps and five conventional metal clamps were used. The clamps were positioned, next to an aluminum scale, under the same phosphor plate to perform 3 radiographs. The locator cylinder was set perpendicular to the radiographic films at a focal length of 20 cm and set to 60 kVp and 0.06 seconds. After image processing, optical density values were read using DBWin 5.0.4 software. The mean of the 3 readings taken on each clamp was adopted as the radiodensity of the specimen. The differences between the groups were compared using Student’s t-test (p<0.05). RESULTS: Polyethylene terephthalate clamps demonstrated significantly lower radiopacity than conventional metal clamps (p<0.05). CONCLUSIONS: Polyethylene terephthalate clamps have lower radiopacity when compared to conventional metal clamps. Key words:Rubber Dams, Dentistry, Operative, Endodontics. Medicina Oral S.L. 2022-08-01 /pmc/articles/PMC9422974/ /pubmed/36046164 http://dx.doi.org/10.4317/jced.59603 Text en Copyright: © 2022 Medicina Oral S.L. https://creativecommons.org/licenses/by/2.5/This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Ferreira e Cunha, Anna-Flávia Madalena, Isabela-Ribeiro Küchler, Erika-Calvano Pereira, Tiago-Lima Honorato, Richard de Menezes, Fernando-Carlos-Hueb Lepri, César-Penazzo Oliveira, Maria-Angélica-Hueb-de Menezes Polyethylene terephthalate clamps: Optimization in endodontic and restorative practices |
title | Polyethylene terephthalate clamps: Optimization in endodontic and restorative practices |
title_full | Polyethylene terephthalate clamps: Optimization in endodontic and restorative practices |
title_fullStr | Polyethylene terephthalate clamps: Optimization in endodontic and restorative practices |
title_full_unstemmed | Polyethylene terephthalate clamps: Optimization in endodontic and restorative practices |
title_short | Polyethylene terephthalate clamps: Optimization in endodontic and restorative practices |
title_sort | polyethylene terephthalate clamps: optimization in endodontic and restorative practices |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9422974/ https://www.ncbi.nlm.nih.gov/pubmed/36046164 http://dx.doi.org/10.4317/jced.59603 |
work_keys_str_mv | AT ferreiraecunhaannaflavia polyethyleneterephthalateclampsoptimizationinendodonticandrestorativepractices AT madalenaisabelaribeiro polyethyleneterephthalateclampsoptimizationinendodonticandrestorativepractices AT kuchlererikacalvano polyethyleneterephthalateclampsoptimizationinendodonticandrestorativepractices AT pereiratiagolima polyethyleneterephthalateclampsoptimizationinendodonticandrestorativepractices AT honoratorichard polyethyleneterephthalateclampsoptimizationinendodonticandrestorativepractices AT demenezesfernandocarloshueb polyethyleneterephthalateclampsoptimizationinendodonticandrestorativepractices AT lepricesarpenazzo polyethyleneterephthalateclampsoptimizationinendodonticandrestorativepractices AT oliveiramariaangelicahuebdemenezes polyethyleneterephthalateclampsoptimizationinendodonticandrestorativepractices |