Cargando…

Spiral Suture of the Lower Uterine Segment with Temporary Aortic Balloon Occlusion in Morbidly Adherent Placenta Previa Cases

PURPOSE: We aimed to investigate the combined effect of spiral suture of the lower uterine segment with intraoperative aortic balloon occlusion in morbidly adherent placenta previa cases. PATIENT AND METHODS: This retrospective, single-center study involved patients from 2017 to 2020. The study cons...

Descripción completa

Detalles Bibliográficos
Autores principales: Yin, Yin, Qu, Lin, Jin, Bai, Yang, Zhengqiang, Xia, Jinguo, Sun, Lizhou, Zhou, Xin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9422986/
https://www.ncbi.nlm.nih.gov/pubmed/36046176
http://dx.doi.org/10.2147/IJWH.S367654
_version_ 1784777930840211456
author Yin, Yin
Qu, Lin
Jin, Bai
Yang, Zhengqiang
Xia, Jinguo
Sun, Lizhou
Zhou, Xin
author_facet Yin, Yin
Qu, Lin
Jin, Bai
Yang, Zhengqiang
Xia, Jinguo
Sun, Lizhou
Zhou, Xin
author_sort Yin, Yin
collection PubMed
description PURPOSE: We aimed to investigate the combined effect of spiral suture of the lower uterine segment with intraoperative aortic balloon occlusion in morbidly adherent placenta previa cases. PATIENT AND METHODS: This retrospective, single-center study involved patients from 2017 to 2020. The study considered 68 cases of morbidly adherent placenta previa cases from medical records retrospectively with age ranging from 23 to 42 years. Bilateral uterine artery embolization was performed, to control excessive bleeding. Perioperative blood loss, hysterectomy rate, amount of blood transfusion, balloon occlusion time, fetal and maternal radiation dose, and postpartum complications were assessed. RESULTS: A total of 68 patients underwent surgery. Hysterectomy was performed in three patients and uterine artery embolization in 21 patients. Of 53 patients who required blood transfusions, the amount of packed red blood cells given was 800 mL and the amount of plasma given was 400 mL. Median abdominal aortic balloon occlusion time was 17 minutes. Fetal and maternal radiation doses were 5 mGy and 12 mGy, respectively. One patient experienced surgery-related complications, a bladder injury. No major catheterization-related and postpartum complications were observed. CONCLUSION: Fertility-sparing surgery for women with morbidly adherent placenta could include abdominal aortic balloon occlusion and spiral suture of lower uterine segment.
format Online
Article
Text
id pubmed-9422986
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Dove
record_format MEDLINE/PubMed
spelling pubmed-94229862022-08-30 Spiral Suture of the Lower Uterine Segment with Temporary Aortic Balloon Occlusion in Morbidly Adherent Placenta Previa Cases Yin, Yin Qu, Lin Jin, Bai Yang, Zhengqiang Xia, Jinguo Sun, Lizhou Zhou, Xin Int J Womens Health Original Research PURPOSE: We aimed to investigate the combined effect of spiral suture of the lower uterine segment with intraoperative aortic balloon occlusion in morbidly adherent placenta previa cases. PATIENT AND METHODS: This retrospective, single-center study involved patients from 2017 to 2020. The study considered 68 cases of morbidly adherent placenta previa cases from medical records retrospectively with age ranging from 23 to 42 years. Bilateral uterine artery embolization was performed, to control excessive bleeding. Perioperative blood loss, hysterectomy rate, amount of blood transfusion, balloon occlusion time, fetal and maternal radiation dose, and postpartum complications were assessed. RESULTS: A total of 68 patients underwent surgery. Hysterectomy was performed in three patients and uterine artery embolization in 21 patients. Of 53 patients who required blood transfusions, the amount of packed red blood cells given was 800 mL and the amount of plasma given was 400 mL. Median abdominal aortic balloon occlusion time was 17 minutes. Fetal and maternal radiation doses were 5 mGy and 12 mGy, respectively. One patient experienced surgery-related complications, a bladder injury. No major catheterization-related and postpartum complications were observed. CONCLUSION: Fertility-sparing surgery for women with morbidly adherent placenta could include abdominal aortic balloon occlusion and spiral suture of lower uterine segment. Dove 2022-08-25 /pmc/articles/PMC9422986/ /pubmed/36046176 http://dx.doi.org/10.2147/IJWH.S367654 Text en © 2022 Yin et al. https://creativecommons.org/licenses/by-nc/3.0/This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/ (https://creativecommons.org/licenses/by-nc/3.0/) ). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php).
spellingShingle Original Research
Yin, Yin
Qu, Lin
Jin, Bai
Yang, Zhengqiang
Xia, Jinguo
Sun, Lizhou
Zhou, Xin
Spiral Suture of the Lower Uterine Segment with Temporary Aortic Balloon Occlusion in Morbidly Adherent Placenta Previa Cases
title Spiral Suture of the Lower Uterine Segment with Temporary Aortic Balloon Occlusion in Morbidly Adherent Placenta Previa Cases
title_full Spiral Suture of the Lower Uterine Segment with Temporary Aortic Balloon Occlusion in Morbidly Adherent Placenta Previa Cases
title_fullStr Spiral Suture of the Lower Uterine Segment with Temporary Aortic Balloon Occlusion in Morbidly Adherent Placenta Previa Cases
title_full_unstemmed Spiral Suture of the Lower Uterine Segment with Temporary Aortic Balloon Occlusion in Morbidly Adherent Placenta Previa Cases
title_short Spiral Suture of the Lower Uterine Segment with Temporary Aortic Balloon Occlusion in Morbidly Adherent Placenta Previa Cases
title_sort spiral suture of the lower uterine segment with temporary aortic balloon occlusion in morbidly adherent placenta previa cases
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9422986/
https://www.ncbi.nlm.nih.gov/pubmed/36046176
http://dx.doi.org/10.2147/IJWH.S367654
work_keys_str_mv AT yinyin spiralsutureoftheloweruterinesegmentwithtemporaryaorticballoonocclusioninmorbidlyadherentplacentapreviacases
AT qulin spiralsutureoftheloweruterinesegmentwithtemporaryaorticballoonocclusioninmorbidlyadherentplacentapreviacases
AT jinbai spiralsutureoftheloweruterinesegmentwithtemporaryaorticballoonocclusioninmorbidlyadherentplacentapreviacases
AT yangzhengqiang spiralsutureoftheloweruterinesegmentwithtemporaryaorticballoonocclusioninmorbidlyadherentplacentapreviacases
AT xiajinguo spiralsutureoftheloweruterinesegmentwithtemporaryaorticballoonocclusioninmorbidlyadherentplacentapreviacases
AT sunlizhou spiralsutureoftheloweruterinesegmentwithtemporaryaorticballoonocclusioninmorbidlyadherentplacentapreviacases
AT zhouxin spiralsutureoftheloweruterinesegmentwithtemporaryaorticballoonocclusioninmorbidlyadherentplacentapreviacases