Cargando…

Kinematic Alignment Bi-unicompartmental Knee Arthroplasty With Oxford Partial Knees: A Technical Note

Bi-unicompartmental knee arthroplasty (BiUKA) is an alternative to total knee arthroplasty for selected patients. Although it is thought to be technically demanding, the technique has not been previously described in detail. Kinematic alignment (KA) implantation and bone cuts parallel to the native...

Descripción completa

Detalles Bibliográficos
Autores principales: Hiranaka, Takafumi, Fujishiro, Takaaki, Koide, Motoki, Okamoto, Koji
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cureus 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9423885/
https://www.ncbi.nlm.nih.gov/pubmed/36059371
http://dx.doi.org/10.7759/cureus.28556
_version_ 1784778114768830464
author Hiranaka, Takafumi
Fujishiro, Takaaki
Koide, Motoki
Okamoto, Koji
author_facet Hiranaka, Takafumi
Fujishiro, Takaaki
Koide, Motoki
Okamoto, Koji
author_sort Hiranaka, Takafumi
collection PubMed
description Bi-unicompartmental knee arthroplasty (BiUKA) is an alternative to total knee arthroplasty for selected patients. Although it is thought to be technically demanding, the technique has not been previously described in detail. Kinematic alignment (KA) implantation and bone cuts parallel to the native joint line would be beneficial to ensure optimal mechanical loading. Here, we detail a technique for KA-BiUKA using the Oxford partial knees. The joint line is identified using the spoon of the microplasty instrumentation system with/without the accessory spoons. The tibia is cut parallel with the joint line using a side-slidable ankle yoke so that the inclination of the cutting block is parallel with the spoon surface. After defining the horizontal bone-cutting lines, the predominantly affected condyle is operated upon, followed by the lesser affected condyle. Although custom-made devices are required, the technique is useful and reproducible in the performance of KA-BiUKA with the Oxford partial knees.
format Online
Article
Text
id pubmed-9423885
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Cureus
record_format MEDLINE/PubMed
spelling pubmed-94238852022-09-02 Kinematic Alignment Bi-unicompartmental Knee Arthroplasty With Oxford Partial Knees: A Technical Note Hiranaka, Takafumi Fujishiro, Takaaki Koide, Motoki Okamoto, Koji Cureus Orthopedics Bi-unicompartmental knee arthroplasty (BiUKA) is an alternative to total knee arthroplasty for selected patients. Although it is thought to be technically demanding, the technique has not been previously described in detail. Kinematic alignment (KA) implantation and bone cuts parallel to the native joint line would be beneficial to ensure optimal mechanical loading. Here, we detail a technique for KA-BiUKA using the Oxford partial knees. The joint line is identified using the spoon of the microplasty instrumentation system with/without the accessory spoons. The tibia is cut parallel with the joint line using a side-slidable ankle yoke so that the inclination of the cutting block is parallel with the spoon surface. After defining the horizontal bone-cutting lines, the predominantly affected condyle is operated upon, followed by the lesser affected condyle. Although custom-made devices are required, the technique is useful and reproducible in the performance of KA-BiUKA with the Oxford partial knees. Cureus 2022-08-29 /pmc/articles/PMC9423885/ /pubmed/36059371 http://dx.doi.org/10.7759/cureus.28556 Text en Copyright © 2022, Hiranaka et al. https://creativecommons.org/licenses/by/3.0/This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Orthopedics
Hiranaka, Takafumi
Fujishiro, Takaaki
Koide, Motoki
Okamoto, Koji
Kinematic Alignment Bi-unicompartmental Knee Arthroplasty With Oxford Partial Knees: A Technical Note
title Kinematic Alignment Bi-unicompartmental Knee Arthroplasty With Oxford Partial Knees: A Technical Note
title_full Kinematic Alignment Bi-unicompartmental Knee Arthroplasty With Oxford Partial Knees: A Technical Note
title_fullStr Kinematic Alignment Bi-unicompartmental Knee Arthroplasty With Oxford Partial Knees: A Technical Note
title_full_unstemmed Kinematic Alignment Bi-unicompartmental Knee Arthroplasty With Oxford Partial Knees: A Technical Note
title_short Kinematic Alignment Bi-unicompartmental Knee Arthroplasty With Oxford Partial Knees: A Technical Note
title_sort kinematic alignment bi-unicompartmental knee arthroplasty with oxford partial knees: a technical note
topic Orthopedics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9423885/
https://www.ncbi.nlm.nih.gov/pubmed/36059371
http://dx.doi.org/10.7759/cureus.28556
work_keys_str_mv AT hiranakatakafumi kinematicalignmentbiunicompartmentalkneearthroplastywithoxfordpartialkneesatechnicalnote
AT fujishirotakaaki kinematicalignmentbiunicompartmentalkneearthroplastywithoxfordpartialkneesatechnicalnote
AT koidemotoki kinematicalignmentbiunicompartmentalkneearthroplastywithoxfordpartialkneesatechnicalnote
AT okamotokoji kinematicalignmentbiunicompartmentalkneearthroplastywithoxfordpartialkneesatechnicalnote