Cargando…
Kinematic Alignment Bi-unicompartmental Knee Arthroplasty With Oxford Partial Knees: A Technical Note
Bi-unicompartmental knee arthroplasty (BiUKA) is an alternative to total knee arthroplasty for selected patients. Although it is thought to be technically demanding, the technique has not been previously described in detail. Kinematic alignment (KA) implantation and bone cuts parallel to the native...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Cureus
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9423885/ https://www.ncbi.nlm.nih.gov/pubmed/36059371 http://dx.doi.org/10.7759/cureus.28556 |
_version_ | 1784778114768830464 |
---|---|
author | Hiranaka, Takafumi Fujishiro, Takaaki Koide, Motoki Okamoto, Koji |
author_facet | Hiranaka, Takafumi Fujishiro, Takaaki Koide, Motoki Okamoto, Koji |
author_sort | Hiranaka, Takafumi |
collection | PubMed |
description | Bi-unicompartmental knee arthroplasty (BiUKA) is an alternative to total knee arthroplasty for selected patients. Although it is thought to be technically demanding, the technique has not been previously described in detail. Kinematic alignment (KA) implantation and bone cuts parallel to the native joint line would be beneficial to ensure optimal mechanical loading. Here, we detail a technique for KA-BiUKA using the Oxford partial knees. The joint line is identified using the spoon of the microplasty instrumentation system with/without the accessory spoons. The tibia is cut parallel with the joint line using a side-slidable ankle yoke so that the inclination of the cutting block is parallel with the spoon surface. After defining the horizontal bone-cutting lines, the predominantly affected condyle is operated upon, followed by the lesser affected condyle. Although custom-made devices are required, the technique is useful and reproducible in the performance of KA-BiUKA with the Oxford partial knees. |
format | Online Article Text |
id | pubmed-9423885 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Cureus |
record_format | MEDLINE/PubMed |
spelling | pubmed-94238852022-09-02 Kinematic Alignment Bi-unicompartmental Knee Arthroplasty With Oxford Partial Knees: A Technical Note Hiranaka, Takafumi Fujishiro, Takaaki Koide, Motoki Okamoto, Koji Cureus Orthopedics Bi-unicompartmental knee arthroplasty (BiUKA) is an alternative to total knee arthroplasty for selected patients. Although it is thought to be technically demanding, the technique has not been previously described in detail. Kinematic alignment (KA) implantation and bone cuts parallel to the native joint line would be beneficial to ensure optimal mechanical loading. Here, we detail a technique for KA-BiUKA using the Oxford partial knees. The joint line is identified using the spoon of the microplasty instrumentation system with/without the accessory spoons. The tibia is cut parallel with the joint line using a side-slidable ankle yoke so that the inclination of the cutting block is parallel with the spoon surface. After defining the horizontal bone-cutting lines, the predominantly affected condyle is operated upon, followed by the lesser affected condyle. Although custom-made devices are required, the technique is useful and reproducible in the performance of KA-BiUKA with the Oxford partial knees. Cureus 2022-08-29 /pmc/articles/PMC9423885/ /pubmed/36059371 http://dx.doi.org/10.7759/cureus.28556 Text en Copyright © 2022, Hiranaka et al. https://creativecommons.org/licenses/by/3.0/This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Orthopedics Hiranaka, Takafumi Fujishiro, Takaaki Koide, Motoki Okamoto, Koji Kinematic Alignment Bi-unicompartmental Knee Arthroplasty With Oxford Partial Knees: A Technical Note |
title | Kinematic Alignment Bi-unicompartmental Knee Arthroplasty With Oxford Partial Knees: A Technical Note |
title_full | Kinematic Alignment Bi-unicompartmental Knee Arthroplasty With Oxford Partial Knees: A Technical Note |
title_fullStr | Kinematic Alignment Bi-unicompartmental Knee Arthroplasty With Oxford Partial Knees: A Technical Note |
title_full_unstemmed | Kinematic Alignment Bi-unicompartmental Knee Arthroplasty With Oxford Partial Knees: A Technical Note |
title_short | Kinematic Alignment Bi-unicompartmental Knee Arthroplasty With Oxford Partial Knees: A Technical Note |
title_sort | kinematic alignment bi-unicompartmental knee arthroplasty with oxford partial knees: a technical note |
topic | Orthopedics |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9423885/ https://www.ncbi.nlm.nih.gov/pubmed/36059371 http://dx.doi.org/10.7759/cureus.28556 |
work_keys_str_mv | AT hiranakatakafumi kinematicalignmentbiunicompartmentalkneearthroplastywithoxfordpartialkneesatechnicalnote AT fujishirotakaaki kinematicalignmentbiunicompartmentalkneearthroplastywithoxfordpartialkneesatechnicalnote AT koidemotoki kinematicalignmentbiunicompartmentalkneearthroplastywithoxfordpartialkneesatechnicalnote AT okamotokoji kinematicalignmentbiunicompartmentalkneearthroplastywithoxfordpartialkneesatechnicalnote |