Cargando…
Wearable Piezoelectric Airflow Transducers for Human Respiratory and Metabolic Monitoring
[Image: see text] Despite the importance of respiration and metabolism measurement in daily life, they are not widely available to ordinary people because of sophisticated and expensive equipment. Here, we first report a straightforward and economical approach to monitoring respiratory function and...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
American Chemical Society
2022
|
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9425556/ https://www.ncbi.nlm.nih.gov/pubmed/35868024 http://dx.doi.org/10.1021/acssensors.2c00824 |
_version_ | 1784778475352096768 |
---|---|
author | Jin, Lu Liu, Zekun Altintas, Mucahit Zheng, Yan Liu, Zhangchi Yao, Sirui Fan, Yangyang Li, Yi |
author_facet | Jin, Lu Liu, Zekun Altintas, Mucahit Zheng, Yan Liu, Zhangchi Yao, Sirui Fan, Yangyang Li, Yi |
author_sort | Jin, Lu |
collection | PubMed |
description | [Image: see text] Despite the importance of respiration and metabolism measurement in daily life, they are not widely available to ordinary people because of sophisticated and expensive equipment. Here, we first report a straightforward and economical approach to monitoring respiratory function and metabolic rate using a wearable piezoelectric airflow transducer (WPAT). A self-shielded bend sensor is designed by sticking two uniaxially drawn piezoelectric poly l-lactic acid films with different cutting angles, and then the bend sensor is mounted on one end of a plastic tube to engineer the WPAT. The airflow sensing principle of the WPAT is theoretically determined through finite element simulation, and the WPAT is calibrated with a pulse calibration method. We prove that the WPAT has similar accuracy (correlation coefficient >0.99) to a pneumotachometer in respiratory flow and lung volume assessment. We demonstrate metabolism measurement using the WPAT and the relationship between minute volume and metabolic rates via human wear trials. The mean difference of measured metabolic rates between the WPAT and a Biopac indirect calorimeter is 0.015 kcal/min, which shows comparable performance. Significantly, unlike the Biopac indirect calorimeter with an airflow sensor, an oxygen gas sensor, and a carbon dioxide gas sensor, we merely use the simple-structured WPAT to measure metabolism. Thus, we expect the WPAT technology to provide a precise, convenient, and cost-effective respiratory and metabolic monitoring solution for next-generation medical home care applications and wearable healthcare systems. |
format | Online Article Text |
id | pubmed-9425556 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | American Chemical Society |
record_format | MEDLINE/PubMed |
spelling | pubmed-94255562022-08-31 Wearable Piezoelectric Airflow Transducers for Human Respiratory and Metabolic Monitoring Jin, Lu Liu, Zekun Altintas, Mucahit Zheng, Yan Liu, Zhangchi Yao, Sirui Fan, Yangyang Li, Yi ACS Sens [Image: see text] Despite the importance of respiration and metabolism measurement in daily life, they are not widely available to ordinary people because of sophisticated and expensive equipment. Here, we first report a straightforward and economical approach to monitoring respiratory function and metabolic rate using a wearable piezoelectric airflow transducer (WPAT). A self-shielded bend sensor is designed by sticking two uniaxially drawn piezoelectric poly l-lactic acid films with different cutting angles, and then the bend sensor is mounted on one end of a plastic tube to engineer the WPAT. The airflow sensing principle of the WPAT is theoretically determined through finite element simulation, and the WPAT is calibrated with a pulse calibration method. We prove that the WPAT has similar accuracy (correlation coefficient >0.99) to a pneumotachometer in respiratory flow and lung volume assessment. We demonstrate metabolism measurement using the WPAT and the relationship between minute volume and metabolic rates via human wear trials. The mean difference of measured metabolic rates between the WPAT and a Biopac indirect calorimeter is 0.015 kcal/min, which shows comparable performance. Significantly, unlike the Biopac indirect calorimeter with an airflow sensor, an oxygen gas sensor, and a carbon dioxide gas sensor, we merely use the simple-structured WPAT to measure metabolism. Thus, we expect the WPAT technology to provide a precise, convenient, and cost-effective respiratory and metabolic monitoring solution for next-generation medical home care applications and wearable healthcare systems. American Chemical Society 2022-07-22 2022-08-26 /pmc/articles/PMC9425556/ /pubmed/35868024 http://dx.doi.org/10.1021/acssensors.2c00824 Text en © 2022 The Authors. Published by American Chemical Society https://creativecommons.org/licenses/by/4.0/Permits the broadest form of re-use including for commercial purposes, provided that author attribution and integrity are maintained (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Jin, Lu Liu, Zekun Altintas, Mucahit Zheng, Yan Liu, Zhangchi Yao, Sirui Fan, Yangyang Li, Yi Wearable Piezoelectric Airflow Transducers for Human Respiratory and Metabolic Monitoring |
title | Wearable Piezoelectric
Airflow Transducers for Human
Respiratory and Metabolic Monitoring |
title_full | Wearable Piezoelectric
Airflow Transducers for Human
Respiratory and Metabolic Monitoring |
title_fullStr | Wearable Piezoelectric
Airflow Transducers for Human
Respiratory and Metabolic Monitoring |
title_full_unstemmed | Wearable Piezoelectric
Airflow Transducers for Human
Respiratory and Metabolic Monitoring |
title_short | Wearable Piezoelectric
Airflow Transducers for Human
Respiratory and Metabolic Monitoring |
title_sort | wearable piezoelectric
airflow transducers for human
respiratory and metabolic monitoring |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9425556/ https://www.ncbi.nlm.nih.gov/pubmed/35868024 http://dx.doi.org/10.1021/acssensors.2c00824 |
work_keys_str_mv | AT jinlu wearablepiezoelectricairflowtransducersforhumanrespiratoryandmetabolicmonitoring AT liuzekun wearablepiezoelectricairflowtransducersforhumanrespiratoryandmetabolicmonitoring AT altintasmucahit wearablepiezoelectricairflowtransducersforhumanrespiratoryandmetabolicmonitoring AT zhengyan wearablepiezoelectricairflowtransducersforhumanrespiratoryandmetabolicmonitoring AT liuzhangchi wearablepiezoelectricairflowtransducersforhumanrespiratoryandmetabolicmonitoring AT yaosirui wearablepiezoelectricairflowtransducersforhumanrespiratoryandmetabolicmonitoring AT fanyangyang wearablepiezoelectricairflowtransducersforhumanrespiratoryandmetabolicmonitoring AT liyi wearablepiezoelectricairflowtransducersforhumanrespiratoryandmetabolicmonitoring |