Cargando…

Wearable Piezoelectric Airflow Transducers for Human Respiratory and Metabolic Monitoring

[Image: see text] Despite the importance of respiration and metabolism measurement in daily life, they are not widely available to ordinary people because of sophisticated and expensive equipment. Here, we first report a straightforward and economical approach to monitoring respiratory function and...

Descripción completa

Detalles Bibliográficos
Autores principales: Jin, Lu, Liu, Zekun, Altintas, Mucahit, Zheng, Yan, Liu, Zhangchi, Yao, Sirui, Fan, Yangyang, Li, Yi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Chemical Society 2022
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9425556/
https://www.ncbi.nlm.nih.gov/pubmed/35868024
http://dx.doi.org/10.1021/acssensors.2c00824
_version_ 1784778475352096768
author Jin, Lu
Liu, Zekun
Altintas, Mucahit
Zheng, Yan
Liu, Zhangchi
Yao, Sirui
Fan, Yangyang
Li, Yi
author_facet Jin, Lu
Liu, Zekun
Altintas, Mucahit
Zheng, Yan
Liu, Zhangchi
Yao, Sirui
Fan, Yangyang
Li, Yi
author_sort Jin, Lu
collection PubMed
description [Image: see text] Despite the importance of respiration and metabolism measurement in daily life, they are not widely available to ordinary people because of sophisticated and expensive equipment. Here, we first report a straightforward and economical approach to monitoring respiratory function and metabolic rate using a wearable piezoelectric airflow transducer (WPAT). A self-shielded bend sensor is designed by sticking two uniaxially drawn piezoelectric poly l-lactic acid films with different cutting angles, and then the bend sensor is mounted on one end of a plastic tube to engineer the WPAT. The airflow sensing principle of the WPAT is theoretically determined through finite element simulation, and the WPAT is calibrated with a pulse calibration method. We prove that the WPAT has similar accuracy (correlation coefficient >0.99) to a pneumotachometer in respiratory flow and lung volume assessment. We demonstrate metabolism measurement using the WPAT and the relationship between minute volume and metabolic rates via human wear trials. The mean difference of measured metabolic rates between the WPAT and a Biopac indirect calorimeter is 0.015 kcal/min, which shows comparable performance. Significantly, unlike the Biopac indirect calorimeter with an airflow sensor, an oxygen gas sensor, and a carbon dioxide gas sensor, we merely use the simple-structured WPAT to measure metabolism. Thus, we expect the WPAT technology to provide a precise, convenient, and cost-effective respiratory and metabolic monitoring solution for next-generation medical home care applications and wearable healthcare systems.
format Online
Article
Text
id pubmed-9425556
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher American Chemical Society
record_format MEDLINE/PubMed
spelling pubmed-94255562022-08-31 Wearable Piezoelectric Airflow Transducers for Human Respiratory and Metabolic Monitoring Jin, Lu Liu, Zekun Altintas, Mucahit Zheng, Yan Liu, Zhangchi Yao, Sirui Fan, Yangyang Li, Yi ACS Sens [Image: see text] Despite the importance of respiration and metabolism measurement in daily life, they are not widely available to ordinary people because of sophisticated and expensive equipment. Here, we first report a straightforward and economical approach to monitoring respiratory function and metabolic rate using a wearable piezoelectric airflow transducer (WPAT). A self-shielded bend sensor is designed by sticking two uniaxially drawn piezoelectric poly l-lactic acid films with different cutting angles, and then the bend sensor is mounted on one end of a plastic tube to engineer the WPAT. The airflow sensing principle of the WPAT is theoretically determined through finite element simulation, and the WPAT is calibrated with a pulse calibration method. We prove that the WPAT has similar accuracy (correlation coefficient >0.99) to a pneumotachometer in respiratory flow and lung volume assessment. We demonstrate metabolism measurement using the WPAT and the relationship between minute volume and metabolic rates via human wear trials. The mean difference of measured metabolic rates between the WPAT and a Biopac indirect calorimeter is 0.015 kcal/min, which shows comparable performance. Significantly, unlike the Biopac indirect calorimeter with an airflow sensor, an oxygen gas sensor, and a carbon dioxide gas sensor, we merely use the simple-structured WPAT to measure metabolism. Thus, we expect the WPAT technology to provide a precise, convenient, and cost-effective respiratory and metabolic monitoring solution for next-generation medical home care applications and wearable healthcare systems. American Chemical Society 2022-07-22 2022-08-26 /pmc/articles/PMC9425556/ /pubmed/35868024 http://dx.doi.org/10.1021/acssensors.2c00824 Text en © 2022 The Authors. Published by American Chemical Society https://creativecommons.org/licenses/by/4.0/Permits the broadest form of re-use including for commercial purposes, provided that author attribution and integrity are maintained (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Jin, Lu
Liu, Zekun
Altintas, Mucahit
Zheng, Yan
Liu, Zhangchi
Yao, Sirui
Fan, Yangyang
Li, Yi
Wearable Piezoelectric Airflow Transducers for Human Respiratory and Metabolic Monitoring
title Wearable Piezoelectric Airflow Transducers for Human Respiratory and Metabolic Monitoring
title_full Wearable Piezoelectric Airflow Transducers for Human Respiratory and Metabolic Monitoring
title_fullStr Wearable Piezoelectric Airflow Transducers for Human Respiratory and Metabolic Monitoring
title_full_unstemmed Wearable Piezoelectric Airflow Transducers for Human Respiratory and Metabolic Monitoring
title_short Wearable Piezoelectric Airflow Transducers for Human Respiratory and Metabolic Monitoring
title_sort wearable piezoelectric airflow transducers for human respiratory and metabolic monitoring
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9425556/
https://www.ncbi.nlm.nih.gov/pubmed/35868024
http://dx.doi.org/10.1021/acssensors.2c00824
work_keys_str_mv AT jinlu wearablepiezoelectricairflowtransducersforhumanrespiratoryandmetabolicmonitoring
AT liuzekun wearablepiezoelectricairflowtransducersforhumanrespiratoryandmetabolicmonitoring
AT altintasmucahit wearablepiezoelectricairflowtransducersforhumanrespiratoryandmetabolicmonitoring
AT zhengyan wearablepiezoelectricairflowtransducersforhumanrespiratoryandmetabolicmonitoring
AT liuzhangchi wearablepiezoelectricairflowtransducersforhumanrespiratoryandmetabolicmonitoring
AT yaosirui wearablepiezoelectricairflowtransducersforhumanrespiratoryandmetabolicmonitoring
AT fanyangyang wearablepiezoelectricairflowtransducersforhumanrespiratoryandmetabolicmonitoring
AT liyi wearablepiezoelectricairflowtransducersforhumanrespiratoryandmetabolicmonitoring