Cargando…
Differential diagnosis and feature visualization for thyroid nodules using computer-aided ultrasonic diagnosis system: initial clinical assessment
BACKGROUND: To assess the diagnostic efficacy of the computer-aided ultrasonic diagnosis system (CAD system) in differentiating benign and malignant thyroid nodules. METHODS: The images of 296 thyroid nodules were included in validation sets. The diagnostic efficacy of the CAD system was compared wi...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9425995/ https://www.ncbi.nlm.nih.gov/pubmed/36042395 http://dx.doi.org/10.1186/s12880-022-00874-7 |
_version_ | 1784778583298801664 |
---|---|
author | Xie, Fang Luo, Yu-Kun Lan, Yu Tian, Xiao-Qi Zhu, Ya-Qiong Jin, Zhuang Zhang, Ying Zhang, Ming-Bo Song, Qing Zhang, Yan |
author_facet | Xie, Fang Luo, Yu-Kun Lan, Yu Tian, Xiao-Qi Zhu, Ya-Qiong Jin, Zhuang Zhang, Ying Zhang, Ming-Bo Song, Qing Zhang, Yan |
author_sort | Xie, Fang |
collection | PubMed |
description | BACKGROUND: To assess the diagnostic efficacy of the computer-aided ultrasonic diagnosis system (CAD system) in differentiating benign and malignant thyroid nodules. METHODS: The images of 296 thyroid nodules were included in validation sets. The diagnostic efficacy of the CAD system was compared with that of junior physicians and senior physicians, as well as that of the combination diagnosis of the CAD system with junior physicians. The diagnostic efficacy of the CAD system for different sizes of thyroid nodules was compared. RESULTS: The diagnostic sensitivity and accuracy of the CAD system were higher than those of junior physicians (83.4% vs. 72.2%, 73.0% vs. 69.6%), but the diagnostic specificity of the CAD system was lower than that of junior physicians (62.1% vs. 66.9%). The diagnostic accuracy of the CAD system was lower than that of senior physicians (73.0% vs. 83.8%). However, the combination diagnosis of the CAD system with junior physicians had higher accuracy (81.8%) and AUC (0.842) than those of either the CAD system or junior physicians alone, and comparable diagnostic performance with those of senior physicians. The Kappa was 0.635 in the combination diagnosis of the CAD system with junior physicians, showing good consistency with the pathological results. The accuracy (76.4%) of the CAD system was the highest for nodules of 1–2 cm. CONCLUSION: The CAD system can effectively assist physicians to identify malignant and benign thyroid nodules, reduce the overdiagnosis and overtreatment of thyroid nodules, avoid unnecessary invasive fine needle aspiration, and improve the diagnostic accuracy of junior physicians. |
format | Online Article Text |
id | pubmed-9425995 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-94259952022-08-31 Differential diagnosis and feature visualization for thyroid nodules using computer-aided ultrasonic diagnosis system: initial clinical assessment Xie, Fang Luo, Yu-Kun Lan, Yu Tian, Xiao-Qi Zhu, Ya-Qiong Jin, Zhuang Zhang, Ying Zhang, Ming-Bo Song, Qing Zhang, Yan BMC Med Imaging Research BACKGROUND: To assess the diagnostic efficacy of the computer-aided ultrasonic diagnosis system (CAD system) in differentiating benign and malignant thyroid nodules. METHODS: The images of 296 thyroid nodules were included in validation sets. The diagnostic efficacy of the CAD system was compared with that of junior physicians and senior physicians, as well as that of the combination diagnosis of the CAD system with junior physicians. The diagnostic efficacy of the CAD system for different sizes of thyroid nodules was compared. RESULTS: The diagnostic sensitivity and accuracy of the CAD system were higher than those of junior physicians (83.4% vs. 72.2%, 73.0% vs. 69.6%), but the diagnostic specificity of the CAD system was lower than that of junior physicians (62.1% vs. 66.9%). The diagnostic accuracy of the CAD system was lower than that of senior physicians (73.0% vs. 83.8%). However, the combination diagnosis of the CAD system with junior physicians had higher accuracy (81.8%) and AUC (0.842) than those of either the CAD system or junior physicians alone, and comparable diagnostic performance with those of senior physicians. The Kappa was 0.635 in the combination diagnosis of the CAD system with junior physicians, showing good consistency with the pathological results. The accuracy (76.4%) of the CAD system was the highest for nodules of 1–2 cm. CONCLUSION: The CAD system can effectively assist physicians to identify malignant and benign thyroid nodules, reduce the overdiagnosis and overtreatment of thyroid nodules, avoid unnecessary invasive fine needle aspiration, and improve the diagnostic accuracy of junior physicians. BioMed Central 2022-08-30 /pmc/articles/PMC9425995/ /pubmed/36042395 http://dx.doi.org/10.1186/s12880-022-00874-7 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Xie, Fang Luo, Yu-Kun Lan, Yu Tian, Xiao-Qi Zhu, Ya-Qiong Jin, Zhuang Zhang, Ying Zhang, Ming-Bo Song, Qing Zhang, Yan Differential diagnosis and feature visualization for thyroid nodules using computer-aided ultrasonic diagnosis system: initial clinical assessment |
title | Differential diagnosis and feature visualization for thyroid nodules using computer-aided ultrasonic diagnosis system: initial clinical assessment |
title_full | Differential diagnosis and feature visualization for thyroid nodules using computer-aided ultrasonic diagnosis system: initial clinical assessment |
title_fullStr | Differential diagnosis and feature visualization for thyroid nodules using computer-aided ultrasonic diagnosis system: initial clinical assessment |
title_full_unstemmed | Differential diagnosis and feature visualization for thyroid nodules using computer-aided ultrasonic diagnosis system: initial clinical assessment |
title_short | Differential diagnosis and feature visualization for thyroid nodules using computer-aided ultrasonic diagnosis system: initial clinical assessment |
title_sort | differential diagnosis and feature visualization for thyroid nodules using computer-aided ultrasonic diagnosis system: initial clinical assessment |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9425995/ https://www.ncbi.nlm.nih.gov/pubmed/36042395 http://dx.doi.org/10.1186/s12880-022-00874-7 |
work_keys_str_mv | AT xiefang differentialdiagnosisandfeaturevisualizationforthyroidnodulesusingcomputeraidedultrasonicdiagnosissysteminitialclinicalassessment AT luoyukun differentialdiagnosisandfeaturevisualizationforthyroidnodulesusingcomputeraidedultrasonicdiagnosissysteminitialclinicalassessment AT lanyu differentialdiagnosisandfeaturevisualizationforthyroidnodulesusingcomputeraidedultrasonicdiagnosissysteminitialclinicalassessment AT tianxiaoqi differentialdiagnosisandfeaturevisualizationforthyroidnodulesusingcomputeraidedultrasonicdiagnosissysteminitialclinicalassessment AT zhuyaqiong differentialdiagnosisandfeaturevisualizationforthyroidnodulesusingcomputeraidedultrasonicdiagnosissysteminitialclinicalassessment AT jinzhuang differentialdiagnosisandfeaturevisualizationforthyroidnodulesusingcomputeraidedultrasonicdiagnosissysteminitialclinicalassessment AT zhangying differentialdiagnosisandfeaturevisualizationforthyroidnodulesusingcomputeraidedultrasonicdiagnosissysteminitialclinicalassessment AT zhangmingbo differentialdiagnosisandfeaturevisualizationforthyroidnodulesusingcomputeraidedultrasonicdiagnosissysteminitialclinicalassessment AT songqing differentialdiagnosisandfeaturevisualizationforthyroidnodulesusingcomputeraidedultrasonicdiagnosissysteminitialclinicalassessment AT zhangyan differentialdiagnosisandfeaturevisualizationforthyroidnodulesusingcomputeraidedultrasonicdiagnosissysteminitialclinicalassessment |