Cargando…

Transesophageal echocardiography-guided implantation of totally implantable venous access devices via the internal jugular vein: retrospective analysis of 297 cases in pediatric patients

BACKGROUND: Accurately positioning totally implantable venous access device (TIVAD) catheters and reducing complications in pediatric patients are important and challenging. A number of studies have shown methods for locating the tip of the TIVAD catheter. We assessed the success and complications o...

Descripción completa

Detalles Bibliográficos
Autores principales: Chen, Yuanzhen, Xing, Dajun, Wu, Lixin, Lin, Huatian, Lin, Ting, Ding, Fang, Xu, Liang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9426001/
https://www.ncbi.nlm.nih.gov/pubmed/36042478
http://dx.doi.org/10.1186/s12957-022-02734-8
_version_ 1784778584277123072
author Chen, Yuanzhen
Xing, Dajun
Wu, Lixin
Lin, Huatian
Lin, Ting
Ding, Fang
Xu, Liang
author_facet Chen, Yuanzhen
Xing, Dajun
Wu, Lixin
Lin, Huatian
Lin, Ting
Ding, Fang
Xu, Liang
author_sort Chen, Yuanzhen
collection PubMed
description BACKGROUND: Accurately positioning totally implantable venous access device (TIVAD) catheters and reducing complications in pediatric patients are important and challenging. A number of studies have shown methods for locating the tip of the TIVAD catheter. We assessed the success and complications of TIVAD implantation guided by transesophageal echocardiography (TEE) via the internal jugular vein (IJV) for 294 patients in this retrospective study. METHODS: From May 2019 to March 2021, 297 cases of TIVADs in our hospital were analyzed in this observational, non-randomized, single-center study. The position of the catheter tip under TEE and chest radiography and rates of periprocedural, early, and late complications were evaluated. RESULTS: The implantation was successful in 242 (82.3%) cases which was in a proper position, and the results were consistent with those of postoperative chest radiography. A total of 72 complications were recorded. Of these, 1 case had a perioperative complication, 66 had early complications, and 5 had late complications after port implantation. The most common complications were local infection and catheter malposition, namely 10 (13.9%) cases of incision infection and 58 (80.6%) cases of catheter malposition. In total, 6 (8.3%) cases of port explantation were required. CONCLUSION: Confirmation of proper TIVAD catheter positioning by TEE through an internal jugular approach in children was accurate and safe.
format Online
Article
Text
id pubmed-9426001
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-94260012022-08-31 Transesophageal echocardiography-guided implantation of totally implantable venous access devices via the internal jugular vein: retrospective analysis of 297 cases in pediatric patients Chen, Yuanzhen Xing, Dajun Wu, Lixin Lin, Huatian Lin, Ting Ding, Fang Xu, Liang World J Surg Oncol Research BACKGROUND: Accurately positioning totally implantable venous access device (TIVAD) catheters and reducing complications in pediatric patients are important and challenging. A number of studies have shown methods for locating the tip of the TIVAD catheter. We assessed the success and complications of TIVAD implantation guided by transesophageal echocardiography (TEE) via the internal jugular vein (IJV) for 294 patients in this retrospective study. METHODS: From May 2019 to March 2021, 297 cases of TIVADs in our hospital were analyzed in this observational, non-randomized, single-center study. The position of the catheter tip under TEE and chest radiography and rates of periprocedural, early, and late complications were evaluated. RESULTS: The implantation was successful in 242 (82.3%) cases which was in a proper position, and the results were consistent with those of postoperative chest radiography. A total of 72 complications were recorded. Of these, 1 case had a perioperative complication, 66 had early complications, and 5 had late complications after port implantation. The most common complications were local infection and catheter malposition, namely 10 (13.9%) cases of incision infection and 58 (80.6%) cases of catheter malposition. In total, 6 (8.3%) cases of port explantation were required. CONCLUSION: Confirmation of proper TIVAD catheter positioning by TEE through an internal jugular approach in children was accurate and safe. BioMed Central 2022-08-30 /pmc/articles/PMC9426001/ /pubmed/36042478 http://dx.doi.org/10.1186/s12957-022-02734-8 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Chen, Yuanzhen
Xing, Dajun
Wu, Lixin
Lin, Huatian
Lin, Ting
Ding, Fang
Xu, Liang
Transesophageal echocardiography-guided implantation of totally implantable venous access devices via the internal jugular vein: retrospective analysis of 297 cases in pediatric patients
title Transesophageal echocardiography-guided implantation of totally implantable venous access devices via the internal jugular vein: retrospective analysis of 297 cases in pediatric patients
title_full Transesophageal echocardiography-guided implantation of totally implantable venous access devices via the internal jugular vein: retrospective analysis of 297 cases in pediatric patients
title_fullStr Transesophageal echocardiography-guided implantation of totally implantable venous access devices via the internal jugular vein: retrospective analysis of 297 cases in pediatric patients
title_full_unstemmed Transesophageal echocardiography-guided implantation of totally implantable venous access devices via the internal jugular vein: retrospective analysis of 297 cases in pediatric patients
title_short Transesophageal echocardiography-guided implantation of totally implantable venous access devices via the internal jugular vein: retrospective analysis of 297 cases in pediatric patients
title_sort transesophageal echocardiography-guided implantation of totally implantable venous access devices via the internal jugular vein: retrospective analysis of 297 cases in pediatric patients
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9426001/
https://www.ncbi.nlm.nih.gov/pubmed/36042478
http://dx.doi.org/10.1186/s12957-022-02734-8
work_keys_str_mv AT chenyuanzhen transesophagealechocardiographyguidedimplantationoftotallyimplantablevenousaccessdevicesviatheinternaljugularveinretrospectiveanalysisof297casesinpediatricpatients
AT xingdajun transesophagealechocardiographyguidedimplantationoftotallyimplantablevenousaccessdevicesviatheinternaljugularveinretrospectiveanalysisof297casesinpediatricpatients
AT wulixin transesophagealechocardiographyguidedimplantationoftotallyimplantablevenousaccessdevicesviatheinternaljugularveinretrospectiveanalysisof297casesinpediatricpatients
AT linhuatian transesophagealechocardiographyguidedimplantationoftotallyimplantablevenousaccessdevicesviatheinternaljugularveinretrospectiveanalysisof297casesinpediatricpatients
AT linting transesophagealechocardiographyguidedimplantationoftotallyimplantablevenousaccessdevicesviatheinternaljugularveinretrospectiveanalysisof297casesinpediatricpatients
AT dingfang transesophagealechocardiographyguidedimplantationoftotallyimplantablevenousaccessdevicesviatheinternaljugularveinretrospectiveanalysisof297casesinpediatricpatients
AT xuliang transesophagealechocardiographyguidedimplantationoftotallyimplantablevenousaccessdevicesviatheinternaljugularveinretrospectiveanalysisof297casesinpediatricpatients