A 28-mm intraocular foreign body removal: The vitreoretinal surgeon’s dilemma

BACKGROUND: Intraocular foreign body (IOFB) removal becomes tricky if its large and impacted in the ocular coats. When confronted with such a combination, the vitreoretinal surgeon will need to modify the surgical plan. This surgical video describes one of such situation encountered during removal o...

Descripción completa

Detalles Bibliográficos
Autores principales: Gangwe, Anil, Barwar, Gulshan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9426066/
https://www.ncbi.nlm.nih.gov/pubmed/35791256
http://dx.doi.org/10.4103/ijo.IJO_1432_22
_version_ 1784778599848476672
author Gangwe, Anil
Barwar, Gulshan
author_facet Gangwe, Anil
Barwar, Gulshan
author_sort Gangwe, Anil
collection PubMed
description BACKGROUND: Intraocular foreign body (IOFB) removal becomes tricky if its large and impacted in the ocular coats. When confronted with such a combination, the vitreoretinal surgeon will need to modify the surgical plan. This surgical video describes one of such situation encountered during removal of a long wooden IOFB impacted in the ocular coats. PURPOSE: The video describes a scenario when the surgeon becomes aware that injury to ocular structure is inevitable due to inherent length of the IOFB. However, a careful assessment of the situation helps the surgeon to identify how he could minimize the damage to the eye and not put vision at risk. SYNOPSIS: A young boy presented with painful loss of vision in left eye since 15 days. Examination showed BCVA of 20/32 and limitation movement in up gaze. Fundus showed hazy media and an IOFB in superior quadrant. It was noted that IOFB was moving with eye movement. The impaction in sclera and extraocular extension was suspected. After pars plana vitrectomy, it was observed that IOFB was longer than what was measured by the scan and it was impacted in the coats. Removal using IOFB forceps further pulled the IOFB into vitreous cavity. A rectangular scleral window was created, IOFB was pushed towards opposite pars plana region to avoid injury to macula, optic nerve, lens and peripheral retina. The IOFB was then removed.The retinal tears were lasered. Three months following the surgery, he developed cataract, which needed surgery. His BCVA at the last follow up visit was 20/25 with attached retina. HIGHLIGHTS: 1. Limitation of movement in presence of linear IOFB shall raise a suspicion of IOFB being impacted in coats and possibility of its extraocular extension; 2.An oblique IOFB posterior to limbus, can have length more in transverse diameter of the eyeball. Though rarely used, an ab-externo approach can be a viable option in such a case to minimise injury to vital structure of the eye, particularly if the IOFB is severely impacted in sclera. ONLINE VIDEO LINK: https://youtu.be/2bF3WLd812o
format Online
Article
Text
id pubmed-9426066
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-94260662022-08-31 A 28-mm intraocular foreign body removal: The vitreoretinal surgeon’s dilemma Gangwe, Anil Barwar, Gulshan Indian J Ophthalmol IJO Videos BACKGROUND: Intraocular foreign body (IOFB) removal becomes tricky if its large and impacted in the ocular coats. When confronted with such a combination, the vitreoretinal surgeon will need to modify the surgical plan. This surgical video describes one of such situation encountered during removal of a long wooden IOFB impacted in the ocular coats. PURPOSE: The video describes a scenario when the surgeon becomes aware that injury to ocular structure is inevitable due to inherent length of the IOFB. However, a careful assessment of the situation helps the surgeon to identify how he could minimize the damage to the eye and not put vision at risk. SYNOPSIS: A young boy presented with painful loss of vision in left eye since 15 days. Examination showed BCVA of 20/32 and limitation movement in up gaze. Fundus showed hazy media and an IOFB in superior quadrant. It was noted that IOFB was moving with eye movement. The impaction in sclera and extraocular extension was suspected. After pars plana vitrectomy, it was observed that IOFB was longer than what was measured by the scan and it was impacted in the coats. Removal using IOFB forceps further pulled the IOFB into vitreous cavity. A rectangular scleral window was created, IOFB was pushed towards opposite pars plana region to avoid injury to macula, optic nerve, lens and peripheral retina. The IOFB was then removed.The retinal tears were lasered. Three months following the surgery, he developed cataract, which needed surgery. His BCVA at the last follow up visit was 20/25 with attached retina. HIGHLIGHTS: 1. Limitation of movement in presence of linear IOFB shall raise a suspicion of IOFB being impacted in coats and possibility of its extraocular extension; 2.An oblique IOFB posterior to limbus, can have length more in transverse diameter of the eyeball. Though rarely used, an ab-externo approach can be a viable option in such a case to minimise injury to vital structure of the eye, particularly if the IOFB is severely impacted in sclera. ONLINE VIDEO LINK: https://youtu.be/2bF3WLd812o Wolters Kluwer - Medknow 2022-07 /pmc/articles/PMC9426066/ /pubmed/35791256 http://dx.doi.org/10.4103/ijo.IJO_1432_22 Text en Copyright: © 2022 Indian Journal of Ophthalmology https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle IJO Videos
Gangwe, Anil
Barwar, Gulshan
A 28-mm intraocular foreign body removal: The vitreoretinal surgeon’s dilemma
title A 28-mm intraocular foreign body removal: The vitreoretinal surgeon’s dilemma
title_full A 28-mm intraocular foreign body removal: The vitreoretinal surgeon’s dilemma
title_fullStr A 28-mm intraocular foreign body removal: The vitreoretinal surgeon’s dilemma
title_full_unstemmed A 28-mm intraocular foreign body removal: The vitreoretinal surgeon’s dilemma
title_short A 28-mm intraocular foreign body removal: The vitreoretinal surgeon’s dilemma
title_sort 28-mm intraocular foreign body removal: the vitreoretinal surgeon’s dilemma
topic IJO Videos
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9426066/
https://www.ncbi.nlm.nih.gov/pubmed/35791256
http://dx.doi.org/10.4103/ijo.IJO_1432_22
work_keys_str_mv AT gangweanil a28mmintraocularforeignbodyremovalthevitreoretinalsurgeonsdilemma
AT barwargulshan a28mmintraocularforeignbodyremovalthevitreoretinalsurgeonsdilemma
AT gangweanil 28mmintraocularforeignbodyremovalthevitreoretinalsurgeonsdilemma
AT barwargulshan 28mmintraocularforeignbodyremovalthevitreoretinalsurgeonsdilemma