Cargando…

Finite element evaluation to compare stress pattern in bone surrounding implant with carbon fiber-reinforced poly-ether-ether-ketone and commercially pure titanium implants

BACKGROUND: Titanium allergy is a main reason for failure of dental implant. Hence, newer implant biomaterials have emerged such as zirconia and carbon or glass fiber reinforced poly-ether-ether-ketone (CFR-PEEK)-based materials. The aim of the present study was to compare the stress pattern in bone...

Descripción completa

Detalles Bibliográficos
Autores principales: Haseeb, Syeda Amtul, K. C., Vinaya, Vijaykumar, Neha, Sree Durga B., Anju, Kumar, Anju S., M. K., Sruthi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9426714/
https://www.ncbi.nlm.nih.gov/pubmed/36051812
http://dx.doi.org/10.4103/njms.njms_354_21
_version_ 1784778742663479296
author Haseeb, Syeda Amtul
K. C., Vinaya
Vijaykumar, Neha
Sree Durga B., Anju
Kumar, Anju S.
M. K., Sruthi
author_facet Haseeb, Syeda Amtul
K. C., Vinaya
Vijaykumar, Neha
Sree Durga B., Anju
Kumar, Anju S.
M. K., Sruthi
author_sort Haseeb, Syeda Amtul
collection PubMed
description BACKGROUND: Titanium allergy is a main reason for failure of dental implant. Hence, newer implant biomaterials have emerged such as zirconia and carbon or glass fiber reinforced poly-ether-ether-ketone (CFR-PEEK)-based materials. The aim of the present study was to compare the stress pattern in bone surrounding implant with CFR-PEEK and commercially pure titanium implant. MATERIALS AND METHODS: Three-dimensional formal model of mandibular first molar partsubstituting with implant supported crown was generated. Implant with dimensions of 10 mm length and 4.3 mm diameter was used in this study. Finite element models of CFR-PEEK and commercially pure titanium implant assemblies were generated. A 100 Newton (N) force was implemented along the long axis and obliquely at 30° to the long axis of implant. Von Mises pressures generated in the bone surrounding implant were analyzed using ANSYS workbench 16.0 and other finite element software. RESULTS: Similar stress distribution was detected in bone surrounding implant with CFR-PEEK implant and commercially pure titanium implant assembly under 100 N force applied vertically and obliquely. CONCLUSION: PEEK reinforced with carbon or glass fiber implants can be a viable alternative in individuals who are more of esthetic concern and who demonstrate allergy to metallic implants.
format Online
Article
Text
id pubmed-9426714
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-94267142022-08-31 Finite element evaluation to compare stress pattern in bone surrounding implant with carbon fiber-reinforced poly-ether-ether-ketone and commercially pure titanium implants Haseeb, Syeda Amtul K. C., Vinaya Vijaykumar, Neha Sree Durga B., Anju Kumar, Anju S. M. K., Sruthi Natl J Maxillofac Surg Original Article BACKGROUND: Titanium allergy is a main reason for failure of dental implant. Hence, newer implant biomaterials have emerged such as zirconia and carbon or glass fiber reinforced poly-ether-ether-ketone (CFR-PEEK)-based materials. The aim of the present study was to compare the stress pattern in bone surrounding implant with CFR-PEEK and commercially pure titanium implant. MATERIALS AND METHODS: Three-dimensional formal model of mandibular first molar partsubstituting with implant supported crown was generated. Implant with dimensions of 10 mm length and 4.3 mm diameter was used in this study. Finite element models of CFR-PEEK and commercially pure titanium implant assemblies were generated. A 100 Newton (N) force was implemented along the long axis and obliquely at 30° to the long axis of implant. Von Mises pressures generated in the bone surrounding implant were analyzed using ANSYS workbench 16.0 and other finite element software. RESULTS: Similar stress distribution was detected in bone surrounding implant with CFR-PEEK implant and commercially pure titanium implant assembly under 100 N force applied vertically and obliquely. CONCLUSION: PEEK reinforced with carbon or glass fiber implants can be a viable alternative in individuals who are more of esthetic concern and who demonstrate allergy to metallic implants. Wolters Kluwer - Medknow 2022 2022-07-15 /pmc/articles/PMC9426714/ /pubmed/36051812 http://dx.doi.org/10.4103/njms.njms_354_21 Text en Copyright: © 2022 National Journal of Maxillofacial Surgery https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Haseeb, Syeda Amtul
K. C., Vinaya
Vijaykumar, Neha
Sree Durga B., Anju
Kumar, Anju S.
M. K., Sruthi
Finite element evaluation to compare stress pattern in bone surrounding implant with carbon fiber-reinforced poly-ether-ether-ketone and commercially pure titanium implants
title Finite element evaluation to compare stress pattern in bone surrounding implant with carbon fiber-reinforced poly-ether-ether-ketone and commercially pure titanium implants
title_full Finite element evaluation to compare stress pattern in bone surrounding implant with carbon fiber-reinforced poly-ether-ether-ketone and commercially pure titanium implants
title_fullStr Finite element evaluation to compare stress pattern in bone surrounding implant with carbon fiber-reinforced poly-ether-ether-ketone and commercially pure titanium implants
title_full_unstemmed Finite element evaluation to compare stress pattern in bone surrounding implant with carbon fiber-reinforced poly-ether-ether-ketone and commercially pure titanium implants
title_short Finite element evaluation to compare stress pattern in bone surrounding implant with carbon fiber-reinforced poly-ether-ether-ketone and commercially pure titanium implants
title_sort finite element evaluation to compare stress pattern in bone surrounding implant with carbon fiber-reinforced poly-ether-ether-ketone and commercially pure titanium implants
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9426714/
https://www.ncbi.nlm.nih.gov/pubmed/36051812
http://dx.doi.org/10.4103/njms.njms_354_21
work_keys_str_mv AT haseebsyedaamtul finiteelementevaluationtocomparestresspatterninbonesurroundingimplantwithcarbonfiberreinforcedpolyetheretherketoneandcommerciallypuretitaniumimplants
AT kcvinaya finiteelementevaluationtocomparestresspatterninbonesurroundingimplantwithcarbonfiberreinforcedpolyetheretherketoneandcommerciallypuretitaniumimplants
AT vijaykumarneha finiteelementevaluationtocomparestresspatterninbonesurroundingimplantwithcarbonfiberreinforcedpolyetheretherketoneandcommerciallypuretitaniumimplants
AT sreedurgabanju finiteelementevaluationtocomparestresspatterninbonesurroundingimplantwithcarbonfiberreinforcedpolyetheretherketoneandcommerciallypuretitaniumimplants
AT kumaranjus finiteelementevaluationtocomparestresspatterninbonesurroundingimplantwithcarbonfiberreinforcedpolyetheretherketoneandcommerciallypuretitaniumimplants
AT mksruthi finiteelementevaluationtocomparestresspatterninbonesurroundingimplantwithcarbonfiberreinforcedpolyetheretherketoneandcommerciallypuretitaniumimplants