Cargando…
Finite element evaluation to compare stress pattern in bone surrounding implant with carbon fiber-reinforced poly-ether-ether-ketone and commercially pure titanium implants
BACKGROUND: Titanium allergy is a main reason for failure of dental implant. Hence, newer implant biomaterials have emerged such as zirconia and carbon or glass fiber reinforced poly-ether-ether-ketone (CFR-PEEK)-based materials. The aim of the present study was to compare the stress pattern in bone...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9426714/ https://www.ncbi.nlm.nih.gov/pubmed/36051812 http://dx.doi.org/10.4103/njms.njms_354_21 |
_version_ | 1784778742663479296 |
---|---|
author | Haseeb, Syeda Amtul K. C., Vinaya Vijaykumar, Neha Sree Durga B., Anju Kumar, Anju S. M. K., Sruthi |
author_facet | Haseeb, Syeda Amtul K. C., Vinaya Vijaykumar, Neha Sree Durga B., Anju Kumar, Anju S. M. K., Sruthi |
author_sort | Haseeb, Syeda Amtul |
collection | PubMed |
description | BACKGROUND: Titanium allergy is a main reason for failure of dental implant. Hence, newer implant biomaterials have emerged such as zirconia and carbon or glass fiber reinforced poly-ether-ether-ketone (CFR-PEEK)-based materials. The aim of the present study was to compare the stress pattern in bone surrounding implant with CFR-PEEK and commercially pure titanium implant. MATERIALS AND METHODS: Three-dimensional formal model of mandibular first molar partsubstituting with implant supported crown was generated. Implant with dimensions of 10 mm length and 4.3 mm diameter was used in this study. Finite element models of CFR-PEEK and commercially pure titanium implant assemblies were generated. A 100 Newton (N) force was implemented along the long axis and obliquely at 30° to the long axis of implant. Von Mises pressures generated in the bone surrounding implant were analyzed using ANSYS workbench 16.0 and other finite element software. RESULTS: Similar stress distribution was detected in bone surrounding implant with CFR-PEEK implant and commercially pure titanium implant assembly under 100 N force applied vertically and obliquely. CONCLUSION: PEEK reinforced with carbon or glass fiber implants can be a viable alternative in individuals who are more of esthetic concern and who demonstrate allergy to metallic implants. |
format | Online Article Text |
id | pubmed-9426714 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-94267142022-08-31 Finite element evaluation to compare stress pattern in bone surrounding implant with carbon fiber-reinforced poly-ether-ether-ketone and commercially pure titanium implants Haseeb, Syeda Amtul K. C., Vinaya Vijaykumar, Neha Sree Durga B., Anju Kumar, Anju S. M. K., Sruthi Natl J Maxillofac Surg Original Article BACKGROUND: Titanium allergy is a main reason for failure of dental implant. Hence, newer implant biomaterials have emerged such as zirconia and carbon or glass fiber reinforced poly-ether-ether-ketone (CFR-PEEK)-based materials. The aim of the present study was to compare the stress pattern in bone surrounding implant with CFR-PEEK and commercially pure titanium implant. MATERIALS AND METHODS: Three-dimensional formal model of mandibular first molar partsubstituting with implant supported crown was generated. Implant with dimensions of 10 mm length and 4.3 mm diameter was used in this study. Finite element models of CFR-PEEK and commercially pure titanium implant assemblies were generated. A 100 Newton (N) force was implemented along the long axis and obliquely at 30° to the long axis of implant. Von Mises pressures generated in the bone surrounding implant were analyzed using ANSYS workbench 16.0 and other finite element software. RESULTS: Similar stress distribution was detected in bone surrounding implant with CFR-PEEK implant and commercially pure titanium implant assembly under 100 N force applied vertically and obliquely. CONCLUSION: PEEK reinforced with carbon or glass fiber implants can be a viable alternative in individuals who are more of esthetic concern and who demonstrate allergy to metallic implants. Wolters Kluwer - Medknow 2022 2022-07-15 /pmc/articles/PMC9426714/ /pubmed/36051812 http://dx.doi.org/10.4103/njms.njms_354_21 Text en Copyright: © 2022 National Journal of Maxillofacial Surgery https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Haseeb, Syeda Amtul K. C., Vinaya Vijaykumar, Neha Sree Durga B., Anju Kumar, Anju S. M. K., Sruthi Finite element evaluation to compare stress pattern in bone surrounding implant with carbon fiber-reinforced poly-ether-ether-ketone and commercially pure titanium implants |
title | Finite element evaluation to compare stress pattern in bone surrounding implant with carbon fiber-reinforced poly-ether-ether-ketone and commercially pure titanium implants |
title_full | Finite element evaluation to compare stress pattern in bone surrounding implant with carbon fiber-reinforced poly-ether-ether-ketone and commercially pure titanium implants |
title_fullStr | Finite element evaluation to compare stress pattern in bone surrounding implant with carbon fiber-reinforced poly-ether-ether-ketone and commercially pure titanium implants |
title_full_unstemmed | Finite element evaluation to compare stress pattern in bone surrounding implant with carbon fiber-reinforced poly-ether-ether-ketone and commercially pure titanium implants |
title_short | Finite element evaluation to compare stress pattern in bone surrounding implant with carbon fiber-reinforced poly-ether-ether-ketone and commercially pure titanium implants |
title_sort | finite element evaluation to compare stress pattern in bone surrounding implant with carbon fiber-reinforced poly-ether-ether-ketone and commercially pure titanium implants |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9426714/ https://www.ncbi.nlm.nih.gov/pubmed/36051812 http://dx.doi.org/10.4103/njms.njms_354_21 |
work_keys_str_mv | AT haseebsyedaamtul finiteelementevaluationtocomparestresspatterninbonesurroundingimplantwithcarbonfiberreinforcedpolyetheretherketoneandcommerciallypuretitaniumimplants AT kcvinaya finiteelementevaluationtocomparestresspatterninbonesurroundingimplantwithcarbonfiberreinforcedpolyetheretherketoneandcommerciallypuretitaniumimplants AT vijaykumarneha finiteelementevaluationtocomparestresspatterninbonesurroundingimplantwithcarbonfiberreinforcedpolyetheretherketoneandcommerciallypuretitaniumimplants AT sreedurgabanju finiteelementevaluationtocomparestresspatterninbonesurroundingimplantwithcarbonfiberreinforcedpolyetheretherketoneandcommerciallypuretitaniumimplants AT kumaranjus finiteelementevaluationtocomparestresspatterninbonesurroundingimplantwithcarbonfiberreinforcedpolyetheretherketoneandcommerciallypuretitaniumimplants AT mksruthi finiteelementevaluationtocomparestresspatterninbonesurroundingimplantwithcarbonfiberreinforcedpolyetheretherketoneandcommerciallypuretitaniumimplants |