Cargando…

Comparative performances of serologic and molecular assays for detecting human T lymphotropic virus type 1 and type 2 (HTLV-1 and HTLV-2) in patients infected with human immunodeficiency virus type 1 (HIV-1)

The present study evaluated several techniques currently available (commercial kits and in-house assays) for diagnosing human T lymphotropic viruses types 1 and 2 in two groups of patients enrolled at HIV/AIDS specialized care services in São Paulo: Group 1 (G1), n = 1608, 1237 male/371 female, medi...

Descripción completa

Detalles Bibliográficos
Autores principales: Campos, Karoline Rodrigues, Gonçalves, Maria Gisele, Costa, Nadia Aparecida, Caterino-de-Araujo, Adele
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9428028/
https://www.ncbi.nlm.nih.gov/pubmed/28343818
http://dx.doi.org/10.1016/j.bjid.2017.02.005
_version_ 1784779027405340672
author Campos, Karoline Rodrigues
Gonçalves, Maria Gisele
Costa, Nadia Aparecida
Caterino-de-Araujo, Adele
author_facet Campos, Karoline Rodrigues
Gonçalves, Maria Gisele
Costa, Nadia Aparecida
Caterino-de-Araujo, Adele
author_sort Campos, Karoline Rodrigues
collection PubMed
description The present study evaluated several techniques currently available (commercial kits and in-house assays) for diagnosing human T lymphotropic viruses types 1 and 2 in two groups of patients enrolled at HIV/AIDS specialized care services in São Paulo: Group 1 (G1), n = 1608, 1237 male/371 female, median age 44.3 years old, majority using highly active antiretroviral therapy (HAART); G2, n = 1383, 930 male/453 female, median age of 35.6 years old, majority HAART naïve. Enzyme immunoassays [(EIA) Murex and Gold ELISA] were employed for human T lymphotropic viruses types 1 and 2 screening; Western blotting (WB), INNO-LIA (LIA), real-time PCR pol (qPCR), and nested-PCR-RFLP (tax) were used to confirm infection. Samples were considered human T lymphotropic viruses types 1 and 2 positive when there was reactivity using at least one of the four confirmatory assays. By serological screening, 127/2991 samples were positive or borderline, and human T lymphotropic virus infection was confirmed in 108 samples (three EIA-borderline): 56 human T lymphotropic virus type 1 [G1 (27) + G2 (29)]; 45 human T lymphotropic virus type 2 [G1 (21) + G2 (24)]; one human T lymphotropic virus type 1 + human T lymphotropic virus type 2 (G2); six human T lymphotropic virus [G1 (2) + G2 (4)]. Although there were differences in group characteristics, human T lymphotropic viruses types 1 and 2 prevalence was similar [3.1% (G1) and 4.2% (G2), p = 0.113]. The overall sensitivities of LIA, WB, qPCR, and PCR-RFLP were 97.2%, 82.4%, 68.9%, and 68.4%, respectively, with some differences among groups, likely due to the stage of human T lymphotropic virus infection and/or HAART duration. Indeterminate immunoblotting results were detected in G2, possibly due to the seroconversion period. Negative results in molecular assays could be explained by the use of HAART, the occurrence of defective provirus and/or the low circulating proviral load. In conclusion, when determining the human T lymphotropic virus infection, the findings highlight that there is a need to consider the blood samples with borderline results in screening assays. Of all the tested assays, LIA was the assay of choice for detecting human T lymphotropic virus type 1 and human T lymphotropic virus type 2 in human immunodeficiency virus type 1-infected patients.
format Online
Article
Text
id pubmed-9428028
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-94280282022-09-01 Comparative performances of serologic and molecular assays for detecting human T lymphotropic virus type 1 and type 2 (HTLV-1 and HTLV-2) in patients infected with human immunodeficiency virus type 1 (HIV-1) Campos, Karoline Rodrigues Gonçalves, Maria Gisele Costa, Nadia Aparecida Caterino-de-Araujo, Adele Braz J Infect Dis Original Article The present study evaluated several techniques currently available (commercial kits and in-house assays) for diagnosing human T lymphotropic viruses types 1 and 2 in two groups of patients enrolled at HIV/AIDS specialized care services in São Paulo: Group 1 (G1), n = 1608, 1237 male/371 female, median age 44.3 years old, majority using highly active antiretroviral therapy (HAART); G2, n = 1383, 930 male/453 female, median age of 35.6 years old, majority HAART naïve. Enzyme immunoassays [(EIA) Murex and Gold ELISA] were employed for human T lymphotropic viruses types 1 and 2 screening; Western blotting (WB), INNO-LIA (LIA), real-time PCR pol (qPCR), and nested-PCR-RFLP (tax) were used to confirm infection. Samples were considered human T lymphotropic viruses types 1 and 2 positive when there was reactivity using at least one of the four confirmatory assays. By serological screening, 127/2991 samples were positive or borderline, and human T lymphotropic virus infection was confirmed in 108 samples (three EIA-borderline): 56 human T lymphotropic virus type 1 [G1 (27) + G2 (29)]; 45 human T lymphotropic virus type 2 [G1 (21) + G2 (24)]; one human T lymphotropic virus type 1 + human T lymphotropic virus type 2 (G2); six human T lymphotropic virus [G1 (2) + G2 (4)]. Although there were differences in group characteristics, human T lymphotropic viruses types 1 and 2 prevalence was similar [3.1% (G1) and 4.2% (G2), p = 0.113]. The overall sensitivities of LIA, WB, qPCR, and PCR-RFLP were 97.2%, 82.4%, 68.9%, and 68.4%, respectively, with some differences among groups, likely due to the stage of human T lymphotropic virus infection and/or HAART duration. Indeterminate immunoblotting results were detected in G2, possibly due to the seroconversion period. Negative results in molecular assays could be explained by the use of HAART, the occurrence of defective provirus and/or the low circulating proviral load. In conclusion, when determining the human T lymphotropic virus infection, the findings highlight that there is a need to consider the blood samples with borderline results in screening assays. Of all the tested assays, LIA was the assay of choice for detecting human T lymphotropic virus type 1 and human T lymphotropic virus type 2 in human immunodeficiency virus type 1-infected patients. Elsevier 2017-03-24 /pmc/articles/PMC9428028/ /pubmed/28343818 http://dx.doi.org/10.1016/j.bjid.2017.02.005 Text en © 2017 Sociedade Brasileira de Infectologia. Published by Elsevier Editora Ltda. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Article
Campos, Karoline Rodrigues
Gonçalves, Maria Gisele
Costa, Nadia Aparecida
Caterino-de-Araujo, Adele
Comparative performances of serologic and molecular assays for detecting human T lymphotropic virus type 1 and type 2 (HTLV-1 and HTLV-2) in patients infected with human immunodeficiency virus type 1 (HIV-1)
title Comparative performances of serologic and molecular assays for detecting human T lymphotropic virus type 1 and type 2 (HTLV-1 and HTLV-2) in patients infected with human immunodeficiency virus type 1 (HIV-1)
title_full Comparative performances of serologic and molecular assays for detecting human T lymphotropic virus type 1 and type 2 (HTLV-1 and HTLV-2) in patients infected with human immunodeficiency virus type 1 (HIV-1)
title_fullStr Comparative performances of serologic and molecular assays for detecting human T lymphotropic virus type 1 and type 2 (HTLV-1 and HTLV-2) in patients infected with human immunodeficiency virus type 1 (HIV-1)
title_full_unstemmed Comparative performances of serologic and molecular assays for detecting human T lymphotropic virus type 1 and type 2 (HTLV-1 and HTLV-2) in patients infected with human immunodeficiency virus type 1 (HIV-1)
title_short Comparative performances of serologic and molecular assays for detecting human T lymphotropic virus type 1 and type 2 (HTLV-1 and HTLV-2) in patients infected with human immunodeficiency virus type 1 (HIV-1)
title_sort comparative performances of serologic and molecular assays for detecting human t lymphotropic virus type 1 and type 2 (htlv-1 and htlv-2) in patients infected with human immunodeficiency virus type 1 (hiv-1)
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9428028/
https://www.ncbi.nlm.nih.gov/pubmed/28343818
http://dx.doi.org/10.1016/j.bjid.2017.02.005
work_keys_str_mv AT camposkarolinerodrigues comparativeperformancesofserologicandmolecularassaysfordetectinghumantlymphotropicvirustype1andtype2htlv1andhtlv2inpatientsinfectedwithhumanimmunodeficiencyvirustype1hiv1
AT goncalvesmariagisele comparativeperformancesofserologicandmolecularassaysfordetectinghumantlymphotropicvirustype1andtype2htlv1andhtlv2inpatientsinfectedwithhumanimmunodeficiencyvirustype1hiv1
AT costanadiaaparecida comparativeperformancesofserologicandmolecularassaysfordetectinghumantlymphotropicvirustype1andtype2htlv1andhtlv2inpatientsinfectedwithhumanimmunodeficiencyvirustype1hiv1
AT caterinodearaujoadele comparativeperformancesofserologicandmolecularassaysfordetectinghumantlymphotropicvirustype1andtype2htlv1andhtlv2inpatientsinfectedwithhumanimmunodeficiencyvirustype1hiv1