Cargando…

External validation of the Tyrolean hip arthroplasty registry

PURPOSE: Arthroplasty registries gained increasing importance to the re-certification of orthopaedic implants according to the European Union (EU) Medical Device Regulation (MDR) adopted in 2017. Until recently, several European countries only had regional arthroplasty registries. Whether regional r...

Descripción completa

Detalles Bibliográficos
Autores principales: Wagner, Moritz, Neururer, Sabrina, Dammerer, Dietmar, Nardelli, Paul, Kaufmann, Gerhard, Braito, Matthias, Brunner, Alexander
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9428074/
https://www.ncbi.nlm.nih.gov/pubmed/36042064
http://dx.doi.org/10.1186/s40634-022-00526-3
_version_ 1784779036463988736
author Wagner, Moritz
Neururer, Sabrina
Dammerer, Dietmar
Nardelli, Paul
Kaufmann, Gerhard
Braito, Matthias
Brunner, Alexander
author_facet Wagner, Moritz
Neururer, Sabrina
Dammerer, Dietmar
Nardelli, Paul
Kaufmann, Gerhard
Braito, Matthias
Brunner, Alexander
author_sort Wagner, Moritz
collection PubMed
description PURPOSE: Arthroplasty registries gained increasing importance to the re-certification of orthopaedic implants according to the European Union (EU) Medical Device Regulation (MDR) adopted in 2017. Until recently, several European countries only had regional arthroplasty registries. Whether regional registries deliver data quality comparable with national registries remained unclear. Therefore, the purpose of this study was to validate the Austrian Tyrolean Hip Arthroplasty Registry (THAR) and to evaluate if this regional registry showed adequate adherence, completeness and correctness when compared with well-established national registries. METHODS: A consecutive series of 1100 primary total hip arthroplasties were identified from our institution’s medical database. Patients were interviewed by phone and completed questionnaires after a mean follow-up period of 8.05 years and were asked if they had had revision surgeries. The data were compared to the corresponding dataset from the THAR. RESULTS: Adherence was 97.91% for primary total hip arthroplasty. Clinical follow-up identified 10 missing cases, resulting in adherence of 81.48% for revisions. Completeness of patient-reported outcome measurements was 78.55% before surgery and 84.45% 1 year after surgery. Correctness was 99.7% for demographic data, 99.54% for implant specifications, and 99.35% for mode of fixation. CONCLUSION: The data of this study showed that regional arthroplasty registries can deliver data quality comparable with well-established national registries. The main reason for unrecorded revision cases and wrongly recoded implants was human error. Further digitalization with more automatic data submission may have the potential to reduce these failure rates in the future. Overall, the THAR represents a valid data source for re-certification of medical implants according to the EU’s MDR.
format Online
Article
Text
id pubmed-9428074
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-94280742022-09-01 External validation of the Tyrolean hip arthroplasty registry Wagner, Moritz Neururer, Sabrina Dammerer, Dietmar Nardelli, Paul Kaufmann, Gerhard Braito, Matthias Brunner, Alexander J Exp Orthop Original Paper PURPOSE: Arthroplasty registries gained increasing importance to the re-certification of orthopaedic implants according to the European Union (EU) Medical Device Regulation (MDR) adopted in 2017. Until recently, several European countries only had regional arthroplasty registries. Whether regional registries deliver data quality comparable with national registries remained unclear. Therefore, the purpose of this study was to validate the Austrian Tyrolean Hip Arthroplasty Registry (THAR) and to evaluate if this regional registry showed adequate adherence, completeness and correctness when compared with well-established national registries. METHODS: A consecutive series of 1100 primary total hip arthroplasties were identified from our institution’s medical database. Patients were interviewed by phone and completed questionnaires after a mean follow-up period of 8.05 years and were asked if they had had revision surgeries. The data were compared to the corresponding dataset from the THAR. RESULTS: Adherence was 97.91% for primary total hip arthroplasty. Clinical follow-up identified 10 missing cases, resulting in adherence of 81.48% for revisions. Completeness of patient-reported outcome measurements was 78.55% before surgery and 84.45% 1 year after surgery. Correctness was 99.7% for demographic data, 99.54% for implant specifications, and 99.35% for mode of fixation. CONCLUSION: The data of this study showed that regional arthroplasty registries can deliver data quality comparable with well-established national registries. The main reason for unrecorded revision cases and wrongly recoded implants was human error. Further digitalization with more automatic data submission may have the potential to reduce these failure rates in the future. Overall, the THAR represents a valid data source for re-certification of medical implants according to the EU’s MDR. Springer Berlin Heidelberg 2022-08-30 /pmc/articles/PMC9428074/ /pubmed/36042064 http://dx.doi.org/10.1186/s40634-022-00526-3 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Original Paper
Wagner, Moritz
Neururer, Sabrina
Dammerer, Dietmar
Nardelli, Paul
Kaufmann, Gerhard
Braito, Matthias
Brunner, Alexander
External validation of the Tyrolean hip arthroplasty registry
title External validation of the Tyrolean hip arthroplasty registry
title_full External validation of the Tyrolean hip arthroplasty registry
title_fullStr External validation of the Tyrolean hip arthroplasty registry
title_full_unstemmed External validation of the Tyrolean hip arthroplasty registry
title_short External validation of the Tyrolean hip arthroplasty registry
title_sort external validation of the tyrolean hip arthroplasty registry
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9428074/
https://www.ncbi.nlm.nih.gov/pubmed/36042064
http://dx.doi.org/10.1186/s40634-022-00526-3
work_keys_str_mv AT wagnermoritz externalvalidationofthetyroleanhiparthroplastyregistry
AT neururersabrina externalvalidationofthetyroleanhiparthroplastyregistry
AT dammererdietmar externalvalidationofthetyroleanhiparthroplastyregistry
AT nardellipaul externalvalidationofthetyroleanhiparthroplastyregistry
AT kaufmanngerhard externalvalidationofthetyroleanhiparthroplastyregistry
AT braitomatthias externalvalidationofthetyroleanhiparthroplastyregistry
AT brunneralexander externalvalidationofthetyroleanhiparthroplastyregistry