Cargando…

Clinical evaluation of an automated TSI bridge immunoassay in the diagnosis of Graves’ disease and its relationship to the degree of hyperthyroidism

BACKGROUND: The rapid and accurate detection of thyroid-stimulating hormone (TSH) receptor antibodies has always been an urgent need for the clinical diagnosis and management of Graves’ disease (GD). We aimed to evaluate the use of an automated thyroid-stimulating immunoglobulin (TSI) bridge immunoa...

Descripción completa

Detalles Bibliográficos
Autores principales: Liu, Tianqi, Zhang, Xiuying, Long, Li, Zhou, Lingli, Chen, Jing, Li, Meng, Gao, Ying, Zhou, Xianghai, Han, Xueyao, Ji, Linong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9429690/
https://www.ncbi.nlm.nih.gov/pubmed/36045442
http://dx.doi.org/10.1186/s12902-022-01114-3
_version_ 1784779537342529536
author Liu, Tianqi
Zhang, Xiuying
Long, Li
Zhou, Lingli
Chen, Jing
Li, Meng
Gao, Ying
Zhou, Xianghai
Han, Xueyao
Ji, Linong
author_facet Liu, Tianqi
Zhang, Xiuying
Long, Li
Zhou, Lingli
Chen, Jing
Li, Meng
Gao, Ying
Zhou, Xianghai
Han, Xueyao
Ji, Linong
author_sort Liu, Tianqi
collection PubMed
description BACKGROUND: The rapid and accurate detection of thyroid-stimulating hormone (TSH) receptor antibodies has always been an urgent need for the clinical diagnosis and management of Graves’ disease (GD). We aimed to evaluate the use of an automated thyroid-stimulating immunoglobulin (TSI) bridge immunoassay in the diagnosis of GD and to analyze the relationship between TSI and the degree of hyperthyroidism. METHODS: A total of 227 new-onset GD patients, 29 Hashimoto thyroiditis, 43 non-autoimmune thyroid diseases and 37 euthyroid controls were consecutively recruited. All participants accepted the measurement of their serum thyroid function and thyroid-associated antibodies, including TSI being measured by an Immulite 2000 bridge immunoassay and TSH receptor autoantibodies (TRAb) being measured by a third-generation Roche electrochemiluminescence immunoassay. The quantitative consistency between the TSI and TRAb detection methods was analyzed by using Passing-Bablok regression and Bland–Altman plots. The diagnostic performance for GD was assessed by receiver operating characteristic (ROC) curve analysis. RESULTS: Among 227 GD patients (174 females and 53 males, with a mean age of 39 years), the quantitative TSI was positively correlated with TRAb (r = 0.8099). According to the cut-off values proposed by the manufacturers (TSI: 0.55 IU/L, TRAb: 1.75 IU/L), the positive rates of TSI and TRAb in new-onset GD patients were 96.92% and 95.15%, respectively. Both TSI and TRAb levels positively correlated with FT(4) levels (TSI: r = 0.243, TRAb: r = 0.317; all P < 0.001) and FT(3) levels (TSI: r = 0.288, TRAb: r = 0.360; all P < 0.001) in new-onset GD patients. The ROC analysis showed that the optimal TSI cut-off value was 0.577 IU/L for GD diagnosis in this Chinese population, with a sensitivity of 96.92% and a specificity of 97.25%, respectively. The optimal TRAb cut-off value of was 1.38 IU/L, with a sensitivity of 96.92% and a specificity of 99.08%. There were no significant differences between the cut-off values obtained through the ROC analysis and those provided by the manufacturer for both TSI and TRAb when calculating their sensitivity and specificity in diagnosing GD. Among the 8 newly diagnosed GD cases with discordant qualitative antibody results, TSI was more likely than TRAb to match the clinical diagnosis of GD (6 TSI-positive vs. 2 TRAb-positive patients). CONCLUSION: The automated TSI bridge immunoassay was positively correlated with thyroxine levels in new-onset GD patients and was more likely to be consistent with the clinical diagnosis of GD than with that of TRAb. The positive Immulite 2000 TSI cut-off value of 0.577 IU/L for GD diagnosis in the Chinese population were close to the value recommended by the manufacturer. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12902-022-01114-3.
format Online
Article
Text
id pubmed-9429690
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-94296902022-09-01 Clinical evaluation of an automated TSI bridge immunoassay in the diagnosis of Graves’ disease and its relationship to the degree of hyperthyroidism Liu, Tianqi Zhang, Xiuying Long, Li Zhou, Lingli Chen, Jing Li, Meng Gao, Ying Zhou, Xianghai Han, Xueyao Ji, Linong BMC Endocr Disord Research BACKGROUND: The rapid and accurate detection of thyroid-stimulating hormone (TSH) receptor antibodies has always been an urgent need for the clinical diagnosis and management of Graves’ disease (GD). We aimed to evaluate the use of an automated thyroid-stimulating immunoglobulin (TSI) bridge immunoassay in the diagnosis of GD and to analyze the relationship between TSI and the degree of hyperthyroidism. METHODS: A total of 227 new-onset GD patients, 29 Hashimoto thyroiditis, 43 non-autoimmune thyroid diseases and 37 euthyroid controls were consecutively recruited. All participants accepted the measurement of their serum thyroid function and thyroid-associated antibodies, including TSI being measured by an Immulite 2000 bridge immunoassay and TSH receptor autoantibodies (TRAb) being measured by a third-generation Roche electrochemiluminescence immunoassay. The quantitative consistency between the TSI and TRAb detection methods was analyzed by using Passing-Bablok regression and Bland–Altman plots. The diagnostic performance for GD was assessed by receiver operating characteristic (ROC) curve analysis. RESULTS: Among 227 GD patients (174 females and 53 males, with a mean age of 39 years), the quantitative TSI was positively correlated with TRAb (r = 0.8099). According to the cut-off values proposed by the manufacturers (TSI: 0.55 IU/L, TRAb: 1.75 IU/L), the positive rates of TSI and TRAb in new-onset GD patients were 96.92% and 95.15%, respectively. Both TSI and TRAb levels positively correlated with FT(4) levels (TSI: r = 0.243, TRAb: r = 0.317; all P < 0.001) and FT(3) levels (TSI: r = 0.288, TRAb: r = 0.360; all P < 0.001) in new-onset GD patients. The ROC analysis showed that the optimal TSI cut-off value was 0.577 IU/L for GD diagnosis in this Chinese population, with a sensitivity of 96.92% and a specificity of 97.25%, respectively. The optimal TRAb cut-off value of was 1.38 IU/L, with a sensitivity of 96.92% and a specificity of 99.08%. There were no significant differences between the cut-off values obtained through the ROC analysis and those provided by the manufacturer for both TSI and TRAb when calculating their sensitivity and specificity in diagnosing GD. Among the 8 newly diagnosed GD cases with discordant qualitative antibody results, TSI was more likely than TRAb to match the clinical diagnosis of GD (6 TSI-positive vs. 2 TRAb-positive patients). CONCLUSION: The automated TSI bridge immunoassay was positively correlated with thyroxine levels in new-onset GD patients and was more likely to be consistent with the clinical diagnosis of GD than with that of TRAb. The positive Immulite 2000 TSI cut-off value of 0.577 IU/L for GD diagnosis in the Chinese population were close to the value recommended by the manufacturer. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12902-022-01114-3. BioMed Central 2022-08-31 /pmc/articles/PMC9429690/ /pubmed/36045442 http://dx.doi.org/10.1186/s12902-022-01114-3 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Liu, Tianqi
Zhang, Xiuying
Long, Li
Zhou, Lingli
Chen, Jing
Li, Meng
Gao, Ying
Zhou, Xianghai
Han, Xueyao
Ji, Linong
Clinical evaluation of an automated TSI bridge immunoassay in the diagnosis of Graves’ disease and its relationship to the degree of hyperthyroidism
title Clinical evaluation of an automated TSI bridge immunoassay in the diagnosis of Graves’ disease and its relationship to the degree of hyperthyroidism
title_full Clinical evaluation of an automated TSI bridge immunoassay in the diagnosis of Graves’ disease and its relationship to the degree of hyperthyroidism
title_fullStr Clinical evaluation of an automated TSI bridge immunoassay in the diagnosis of Graves’ disease and its relationship to the degree of hyperthyroidism
title_full_unstemmed Clinical evaluation of an automated TSI bridge immunoassay in the diagnosis of Graves’ disease and its relationship to the degree of hyperthyroidism
title_short Clinical evaluation of an automated TSI bridge immunoassay in the diagnosis of Graves’ disease and its relationship to the degree of hyperthyroidism
title_sort clinical evaluation of an automated tsi bridge immunoassay in the diagnosis of graves’ disease and its relationship to the degree of hyperthyroidism
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9429690/
https://www.ncbi.nlm.nih.gov/pubmed/36045442
http://dx.doi.org/10.1186/s12902-022-01114-3
work_keys_str_mv AT liutianqi clinicalevaluationofanautomatedtsibridgeimmunoassayinthediagnosisofgravesdiseaseanditsrelationshiptothedegreeofhyperthyroidism
AT zhangxiuying clinicalevaluationofanautomatedtsibridgeimmunoassayinthediagnosisofgravesdiseaseanditsrelationshiptothedegreeofhyperthyroidism
AT longli clinicalevaluationofanautomatedtsibridgeimmunoassayinthediagnosisofgravesdiseaseanditsrelationshiptothedegreeofhyperthyroidism
AT zhoulingli clinicalevaluationofanautomatedtsibridgeimmunoassayinthediagnosisofgravesdiseaseanditsrelationshiptothedegreeofhyperthyroidism
AT chenjing clinicalevaluationofanautomatedtsibridgeimmunoassayinthediagnosisofgravesdiseaseanditsrelationshiptothedegreeofhyperthyroidism
AT limeng clinicalevaluationofanautomatedtsibridgeimmunoassayinthediagnosisofgravesdiseaseanditsrelationshiptothedegreeofhyperthyroidism
AT gaoying clinicalevaluationofanautomatedtsibridgeimmunoassayinthediagnosisofgravesdiseaseanditsrelationshiptothedegreeofhyperthyroidism
AT zhouxianghai clinicalevaluationofanautomatedtsibridgeimmunoassayinthediagnosisofgravesdiseaseanditsrelationshiptothedegreeofhyperthyroidism
AT hanxueyao clinicalevaluationofanautomatedtsibridgeimmunoassayinthediagnosisofgravesdiseaseanditsrelationshiptothedegreeofhyperthyroidism
AT jilinong clinicalevaluationofanautomatedtsibridgeimmunoassayinthediagnosisofgravesdiseaseanditsrelationshiptothedegreeofhyperthyroidism