Cargando…

Multiplex Target-Redundant RT-LAMP for Robust Detection of SARS-CoV-2 Using Fluorescent Universal Displacement Probes

The increasing prevalence of variant lineages during the COVID-19 pandemic has the potential to disrupt molecular diagnostics due to mismatches between primers and variant templates. Point-of-care molecular diagnostics, which often lack the complete functionality of their high-throughput laboratory...

Descripción completa

Detalles Bibliográficos
Autores principales: Kline, Enos C., Panpradist, Nuttada, Hull, Ian T., Wang, Qin, Oreskovic, Amy K., Han, Peter D., Starita, Lea M., Lutz, Barry R.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Society for Microbiology 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9430505/
https://www.ncbi.nlm.nih.gov/pubmed/35708340
http://dx.doi.org/10.1128/spectrum.01583-21
_version_ 1784779787704729600
author Kline, Enos C.
Panpradist, Nuttada
Hull, Ian T.
Wang, Qin
Oreskovic, Amy K.
Han, Peter D.
Starita, Lea M.
Lutz, Barry R.
author_facet Kline, Enos C.
Panpradist, Nuttada
Hull, Ian T.
Wang, Qin
Oreskovic, Amy K.
Han, Peter D.
Starita, Lea M.
Lutz, Barry R.
author_sort Kline, Enos C.
collection PubMed
description The increasing prevalence of variant lineages during the COVID-19 pandemic has the potential to disrupt molecular diagnostics due to mismatches between primers and variant templates. Point-of-care molecular diagnostics, which often lack the complete functionality of their high-throughput laboratory counterparts, are particularly susceptible to this type of disruption, which can result in false-negative results. To address this challenge, we have developed a robust Loop Mediated Isothermal Amplification assay with single tube multiplexed multitarget redundancy and an internal amplification control. A convenient and cost-effective target-specific fluorescence detection system allows amplifications to be grouped by signal using adaptable probes for pooled reporting of SARS-CoV-2 target amplifications or differentiation of the Internal Amplification Control. Over the course of the pandemic, primer coverage of viral lineages by the three redundant sub-assays has varied from assay to assay as they have diverged from the Wuhan-Hu-1 isolate sequence, but aggregate coverage has remained high for all variant sequences analyzed, with a minimum of 97.4% (Variant of Interest: Eta). In three instances (Delta, Gamma, Eta), a high-frequency mismatch with one of the three sub-assays was observed, but overall coverage remained high due to multitarget redundancy. When challenged with extracted human samples the multiplex assay showed 87% or better sensitivity (of 30 positive samples), with 100% sensitivity for samples containing greater than 30 copies of viral RNA per reaction (of 21 positive samples), and 100% specificity (of 60 negative samples). These results are further evidence that conventional laboratory methodologies can be leveraged at the point of care for robust performance and diagnostic stability over time. IMPORTANCE The COVID-19 pandemic has had tremendous impact, and the ability to perform molecular diagnostics in resource limited settings has emerged as a key resource for mitigating spread of the disease. One challenge in COVID-19 diagnosis, as well as other viruses, is ongoing mutation that can allow viruses to evade detection by diagnostic tests. We developed a test that detects multiple parts of the virus genome in a single test to reduce the chance of missing a virus due to mutation, and it is designed to be simpler and faster than typical laboratory tests while maintaining high sensitivity. This capability is enabled by a novel fluorescent probe technology that works with a simple constant temperature reaction condition.
format Online
Article
Text
id pubmed-9430505
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher American Society for Microbiology
record_format MEDLINE/PubMed
spelling pubmed-94305052022-09-01 Multiplex Target-Redundant RT-LAMP for Robust Detection of SARS-CoV-2 Using Fluorescent Universal Displacement Probes Kline, Enos C. Panpradist, Nuttada Hull, Ian T. Wang, Qin Oreskovic, Amy K. Han, Peter D. Starita, Lea M. Lutz, Barry R. Microbiol Spectr Research Article The increasing prevalence of variant lineages during the COVID-19 pandemic has the potential to disrupt molecular diagnostics due to mismatches between primers and variant templates. Point-of-care molecular diagnostics, which often lack the complete functionality of their high-throughput laboratory counterparts, are particularly susceptible to this type of disruption, which can result in false-negative results. To address this challenge, we have developed a robust Loop Mediated Isothermal Amplification assay with single tube multiplexed multitarget redundancy and an internal amplification control. A convenient and cost-effective target-specific fluorescence detection system allows amplifications to be grouped by signal using adaptable probes for pooled reporting of SARS-CoV-2 target amplifications or differentiation of the Internal Amplification Control. Over the course of the pandemic, primer coverage of viral lineages by the three redundant sub-assays has varied from assay to assay as they have diverged from the Wuhan-Hu-1 isolate sequence, but aggregate coverage has remained high for all variant sequences analyzed, with a minimum of 97.4% (Variant of Interest: Eta). In three instances (Delta, Gamma, Eta), a high-frequency mismatch with one of the three sub-assays was observed, but overall coverage remained high due to multitarget redundancy. When challenged with extracted human samples the multiplex assay showed 87% or better sensitivity (of 30 positive samples), with 100% sensitivity for samples containing greater than 30 copies of viral RNA per reaction (of 21 positive samples), and 100% specificity (of 60 negative samples). These results are further evidence that conventional laboratory methodologies can be leveraged at the point of care for robust performance and diagnostic stability over time. IMPORTANCE The COVID-19 pandemic has had tremendous impact, and the ability to perform molecular diagnostics in resource limited settings has emerged as a key resource for mitigating spread of the disease. One challenge in COVID-19 diagnosis, as well as other viruses, is ongoing mutation that can allow viruses to evade detection by diagnostic tests. We developed a test that detects multiple parts of the virus genome in a single test to reduce the chance of missing a virus due to mutation, and it is designed to be simpler and faster than typical laboratory tests while maintaining high sensitivity. This capability is enabled by a novel fluorescent probe technology that works with a simple constant temperature reaction condition. American Society for Microbiology 2022-06-16 /pmc/articles/PMC9430505/ /pubmed/35708340 http://dx.doi.org/10.1128/spectrum.01583-21 Text en Copyright © 2022 Kline et al. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution 4.0 International license (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Research Article
Kline, Enos C.
Panpradist, Nuttada
Hull, Ian T.
Wang, Qin
Oreskovic, Amy K.
Han, Peter D.
Starita, Lea M.
Lutz, Barry R.
Multiplex Target-Redundant RT-LAMP for Robust Detection of SARS-CoV-2 Using Fluorescent Universal Displacement Probes
title Multiplex Target-Redundant RT-LAMP for Robust Detection of SARS-CoV-2 Using Fluorescent Universal Displacement Probes
title_full Multiplex Target-Redundant RT-LAMP for Robust Detection of SARS-CoV-2 Using Fluorescent Universal Displacement Probes
title_fullStr Multiplex Target-Redundant RT-LAMP for Robust Detection of SARS-CoV-2 Using Fluorescent Universal Displacement Probes
title_full_unstemmed Multiplex Target-Redundant RT-LAMP for Robust Detection of SARS-CoV-2 Using Fluorescent Universal Displacement Probes
title_short Multiplex Target-Redundant RT-LAMP for Robust Detection of SARS-CoV-2 Using Fluorescent Universal Displacement Probes
title_sort multiplex target-redundant rt-lamp for robust detection of sars-cov-2 using fluorescent universal displacement probes
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9430505/
https://www.ncbi.nlm.nih.gov/pubmed/35708340
http://dx.doi.org/10.1128/spectrum.01583-21
work_keys_str_mv AT klineenosc multiplextargetredundantrtlampforrobustdetectionofsarscov2usingfluorescentuniversaldisplacementprobes
AT panpradistnuttada multiplextargetredundantrtlampforrobustdetectionofsarscov2usingfluorescentuniversaldisplacementprobes
AT hulliant multiplextargetredundantrtlampforrobustdetectionofsarscov2usingfluorescentuniversaldisplacementprobes
AT wangqin multiplextargetredundantrtlampforrobustdetectionofsarscov2usingfluorescentuniversaldisplacementprobes
AT oreskovicamyk multiplextargetredundantrtlampforrobustdetectionofsarscov2usingfluorescentuniversaldisplacementprobes
AT hanpeterd multiplextargetredundantrtlampforrobustdetectionofsarscov2usingfluorescentuniversaldisplacementprobes
AT staritaleam multiplextargetredundantrtlampforrobustdetectionofsarscov2usingfluorescentuniversaldisplacementprobes
AT lutzbarryr multiplextargetredundantrtlampforrobustdetectionofsarscov2usingfluorescentuniversaldisplacementprobes