Cargando…
High-Throughput COVID-19 Testing of Naso-Oropharyngeal Swabs Using a Sensitive Extraction-Free Sample Preparation Method
High-throughput diagnostic assays are required for large-scale population testing for severe acute respiratory coronavirus 2 (SARS-CoV-2). The gold standard technique for SARS-CoV-2 detection in nasopharyngeal swab specimens is nucleic acid extraction followed by real-time reverse transcription-PCR....
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
American Society for Microbiology
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9430511/ https://www.ncbi.nlm.nih.gov/pubmed/35950846 http://dx.doi.org/10.1128/spectrum.01358-22 |
_version_ | 1784779789500940288 |
---|---|
author | Pryce, Todd M. Haygarth, Erin J. Bordessa, Jessica Jeffery, Courtney T. Kay, Ian D. Flexman, James P. Boan, Peter A. |
author_facet | Pryce, Todd M. Haygarth, Erin J. Bordessa, Jessica Jeffery, Courtney T. Kay, Ian D. Flexman, James P. Boan, Peter A. |
author_sort | Pryce, Todd M. |
collection | PubMed |
description | High-throughput diagnostic assays are required for large-scale population testing for severe acute respiratory coronavirus 2 (SARS-CoV-2). The gold standard technique for SARS-CoV-2 detection in nasopharyngeal swab specimens is nucleic acid extraction followed by real-time reverse transcription-PCR. Two high-throughput commercial extraction and detection systems are used routinely in our laboratory: the Roche cobas SARS-CoV-2 assay (cobas) and the Roche MagNA Pure 96 system combined with the SpeeDx PlexPCR SARS-CoV-2 assay (Plex). As an alternative to more costly instrumentation, or tedious sample pooling to increase throughput, we developed a high-throughput extraction-free sample preparation method for naso-oropharyngeal swabs using the PlexPCR SARS-CoV-2 assay (Direct). A collection of SARS-CoV-2-positive (n = 185) and -negative (n = 354) naso-oropharyngeal swabs in transport medium were tested in parallel to compare Plex to Direct. The overall agreement comparing the qualitative outcomes was 99.3%. The mean cycle of quantification (C(q)) increase and corresponding mean reduction in viral load for Direct ORF1ab and RdRp compared to Plex was 3.11 C(q) (−0.91 log(10) IU/mL) and 4.78 C(q) (−1.35 log(10) IU/mL), respectively. We also compared Direct to a four-sample pool by combining each positive sample (n = 185) with three SARS-CoV-2-negative samples extracted with MagNA Pure 96 and tested with the PlexPCR SARS-CoV-2 assay (Pool). Although less sensitive than Plex or Pool, the Direct method is a sufficiently sensitive and viable approach to increase our throughput by 12,032 results per day. Combining cobas, Plex, and Direct, an overall throughput of 19,364 results can be achieved in a 24-h period. IMPORTANCE Laboratories have experienced extraordinary demand globally for reagents, consumables, and instrumentation, while facing unprecedented testing demand needed for the diagnosis of SARS-CoV-2 infection. A major bottleneck in testing throughput is the purification of viral RNA. Extraction-based methods provide the greatest yield and purity of RNA for downstream PCR. However, these techniques are expensive, time-consuming, and depend on commercial availability of consumables. Extraction-free methods offer an accessible and cost-effective alternative for sample preparation. However, extraction-free methods often lack sensitivity compared to extraction-based methods. We describe a sensitive extraction-free protocol based on a simple purification step using a chelating resin, combined with proteinase K and thermal treatment. We compare the sensitivity qualitatively and quantitatively to a well-known commercial extraction-based system, using a PCR assay calibrated to the 1st WHO international standard for SARS-CoV-2 RNA. This method entails high throughput and is suitable for all laboratories, particularly in jurisdictions where access to instrumentation and reagents is problematic. |
format | Online Article Text |
id | pubmed-9430511 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | American Society for Microbiology |
record_format | MEDLINE/PubMed |
spelling | pubmed-94305112022-09-01 High-Throughput COVID-19 Testing of Naso-Oropharyngeal Swabs Using a Sensitive Extraction-Free Sample Preparation Method Pryce, Todd M. Haygarth, Erin J. Bordessa, Jessica Jeffery, Courtney T. Kay, Ian D. Flexman, James P. Boan, Peter A. Microbiol Spectr Research Article High-throughput diagnostic assays are required for large-scale population testing for severe acute respiratory coronavirus 2 (SARS-CoV-2). The gold standard technique for SARS-CoV-2 detection in nasopharyngeal swab specimens is nucleic acid extraction followed by real-time reverse transcription-PCR. Two high-throughput commercial extraction and detection systems are used routinely in our laboratory: the Roche cobas SARS-CoV-2 assay (cobas) and the Roche MagNA Pure 96 system combined with the SpeeDx PlexPCR SARS-CoV-2 assay (Plex). As an alternative to more costly instrumentation, or tedious sample pooling to increase throughput, we developed a high-throughput extraction-free sample preparation method for naso-oropharyngeal swabs using the PlexPCR SARS-CoV-2 assay (Direct). A collection of SARS-CoV-2-positive (n = 185) and -negative (n = 354) naso-oropharyngeal swabs in transport medium were tested in parallel to compare Plex to Direct. The overall agreement comparing the qualitative outcomes was 99.3%. The mean cycle of quantification (C(q)) increase and corresponding mean reduction in viral load for Direct ORF1ab and RdRp compared to Plex was 3.11 C(q) (−0.91 log(10) IU/mL) and 4.78 C(q) (−1.35 log(10) IU/mL), respectively. We also compared Direct to a four-sample pool by combining each positive sample (n = 185) with three SARS-CoV-2-negative samples extracted with MagNA Pure 96 and tested with the PlexPCR SARS-CoV-2 assay (Pool). Although less sensitive than Plex or Pool, the Direct method is a sufficiently sensitive and viable approach to increase our throughput by 12,032 results per day. Combining cobas, Plex, and Direct, an overall throughput of 19,364 results can be achieved in a 24-h period. IMPORTANCE Laboratories have experienced extraordinary demand globally for reagents, consumables, and instrumentation, while facing unprecedented testing demand needed for the diagnosis of SARS-CoV-2 infection. A major bottleneck in testing throughput is the purification of viral RNA. Extraction-based methods provide the greatest yield and purity of RNA for downstream PCR. However, these techniques are expensive, time-consuming, and depend on commercial availability of consumables. Extraction-free methods offer an accessible and cost-effective alternative for sample preparation. However, extraction-free methods often lack sensitivity compared to extraction-based methods. We describe a sensitive extraction-free protocol based on a simple purification step using a chelating resin, combined with proteinase K and thermal treatment. We compare the sensitivity qualitatively and quantitatively to a well-known commercial extraction-based system, using a PCR assay calibrated to the 1st WHO international standard for SARS-CoV-2 RNA. This method entails high throughput and is suitable for all laboratories, particularly in jurisdictions where access to instrumentation and reagents is problematic. American Society for Microbiology 2022-08-11 /pmc/articles/PMC9430511/ /pubmed/35950846 http://dx.doi.org/10.1128/spectrum.01358-22 Text en © Crown copyright 2022. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution 4.0 International license (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Research Article Pryce, Todd M. Haygarth, Erin J. Bordessa, Jessica Jeffery, Courtney T. Kay, Ian D. Flexman, James P. Boan, Peter A. High-Throughput COVID-19 Testing of Naso-Oropharyngeal Swabs Using a Sensitive Extraction-Free Sample Preparation Method |
title | High-Throughput COVID-19 Testing of Naso-Oropharyngeal Swabs Using a Sensitive Extraction-Free Sample Preparation Method |
title_full | High-Throughput COVID-19 Testing of Naso-Oropharyngeal Swabs Using a Sensitive Extraction-Free Sample Preparation Method |
title_fullStr | High-Throughput COVID-19 Testing of Naso-Oropharyngeal Swabs Using a Sensitive Extraction-Free Sample Preparation Method |
title_full_unstemmed | High-Throughput COVID-19 Testing of Naso-Oropharyngeal Swabs Using a Sensitive Extraction-Free Sample Preparation Method |
title_short | High-Throughput COVID-19 Testing of Naso-Oropharyngeal Swabs Using a Sensitive Extraction-Free Sample Preparation Method |
title_sort | high-throughput covid-19 testing of naso-oropharyngeal swabs using a sensitive extraction-free sample preparation method |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9430511/ https://www.ncbi.nlm.nih.gov/pubmed/35950846 http://dx.doi.org/10.1128/spectrum.01358-22 |
work_keys_str_mv | AT prycetoddm highthroughputcovid19testingofnasooropharyngealswabsusingasensitiveextractionfreesamplepreparationmethod AT haygartherinj highthroughputcovid19testingofnasooropharyngealswabsusingasensitiveextractionfreesamplepreparationmethod AT bordessajessica highthroughputcovid19testingofnasooropharyngealswabsusingasensitiveextractionfreesamplepreparationmethod AT jefferycourtneyt highthroughputcovid19testingofnasooropharyngealswabsusingasensitiveextractionfreesamplepreparationmethod AT kayiand highthroughputcovid19testingofnasooropharyngealswabsusingasensitiveextractionfreesamplepreparationmethod AT flexmanjamesp highthroughputcovid19testingofnasooropharyngealswabsusingasensitiveextractionfreesamplepreparationmethod AT boanpetera highthroughputcovid19testingofnasooropharyngealswabsusingasensitiveextractionfreesamplepreparationmethod |