Cargando…

Multidetector Computed Tomography in Patients with Femoral Neck Fracture for Assessing Osteoporosis: Comparison with Dual Energy X-Ray Absorptiometry

PURPOSE: To evaluate the ability of the Hounsfield unit (HU) measurement of the femoral neck during multidetector computed tomography (MDCT) for assessing osteoporosis compared with dual-energy X-ray absorptiometry (DXA). MATERIALS AND METHODS: Forty-two patients with femoral neck fractures who unde...

Descripción completa

Detalles Bibliográficos
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society of Radiology 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9432397/
https://www.ncbi.nlm.nih.gov/pubmed/36237475
http://dx.doi.org/10.3348/jksr.2019.0193
_version_ 1784780360706424832
collection PubMed
description PURPOSE: To evaluate the ability of the Hounsfield unit (HU) measurement of the femoral neck during multidetector computed tomography (MDCT) for assessing osteoporosis compared with dual-energy X-ray absorptiometry (DXA). MATERIALS AND METHODS: Forty-two patients with femoral neck fractures who underwent MDCT and DXA from July to December 2016 were included in this study. HU measurements were made of the cancellous portions of the normal contralateral femoral neck on MDCT. Bone mineral density (BMD) and T-scores were obtained at the femur DXA. Correlations of HU values with BMD and T-scores were analyzed using Spearman's correlation test. RESULTS: The mean BMD and T-score of the femoral neck were 0.650 g/cm(2) and −2.4, respectively. The mean HU values for the normal, osteopenia, and osteoporosis groups were 131.9, 98.9, and 41.3, respectively. HU values at the femoral neck were positively correlated with BMD (r(2) = 0.670; p < 0.001) and T-scores (r(2) = 0.676; p < 0.001). CONCLUSION: The HU values of the femoral neck on MDCT are significantly correlated with BMD and T-scores of femur DXA. The HU values may serve as a diagnostic tool for the screening of regional bone quality when MDCT is performed for other reasons.
format Online
Article
Text
id pubmed-9432397
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher The Korean Society of Radiology
record_format MEDLINE/PubMed
spelling pubmed-94323972022-10-12 Multidetector Computed Tomography in Patients with Femoral Neck Fracture for Assessing Osteoporosis: Comparison with Dual Energy X-Ray Absorptiometry Taehan Yongsang Uihakhoe Chi Musculoskeletal Imaging PURPOSE: To evaluate the ability of the Hounsfield unit (HU) measurement of the femoral neck during multidetector computed tomography (MDCT) for assessing osteoporosis compared with dual-energy X-ray absorptiometry (DXA). MATERIALS AND METHODS: Forty-two patients with femoral neck fractures who underwent MDCT and DXA from July to December 2016 were included in this study. HU measurements were made of the cancellous portions of the normal contralateral femoral neck on MDCT. Bone mineral density (BMD) and T-scores were obtained at the femur DXA. Correlations of HU values with BMD and T-scores were analyzed using Spearman's correlation test. RESULTS: The mean BMD and T-score of the femoral neck were 0.650 g/cm(2) and −2.4, respectively. The mean HU values for the normal, osteopenia, and osteoporosis groups were 131.9, 98.9, and 41.3, respectively. HU values at the femoral neck were positively correlated with BMD (r(2) = 0.670; p < 0.001) and T-scores (r(2) = 0.676; p < 0.001). CONCLUSION: The HU values of the femoral neck on MDCT are significantly correlated with BMD and T-scores of femur DXA. The HU values may serve as a diagnostic tool for the screening of regional bone quality when MDCT is performed for other reasons. The Korean Society of Radiology 2021-01 2020-11-11 /pmc/articles/PMC9432397/ /pubmed/36237475 http://dx.doi.org/10.3348/jksr.2019.0193 Text en Copyrights © 2021 The Korean Society of Radiology https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (https://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Musculoskeletal Imaging
Multidetector Computed Tomography in Patients with Femoral Neck Fracture for Assessing Osteoporosis: Comparison with Dual Energy X-Ray Absorptiometry
title Multidetector Computed Tomography in Patients with Femoral Neck Fracture for Assessing Osteoporosis: Comparison with Dual Energy X-Ray Absorptiometry
title_full Multidetector Computed Tomography in Patients with Femoral Neck Fracture for Assessing Osteoporosis: Comparison with Dual Energy X-Ray Absorptiometry
title_fullStr Multidetector Computed Tomography in Patients with Femoral Neck Fracture for Assessing Osteoporosis: Comparison with Dual Energy X-Ray Absorptiometry
title_full_unstemmed Multidetector Computed Tomography in Patients with Femoral Neck Fracture for Assessing Osteoporosis: Comparison with Dual Energy X-Ray Absorptiometry
title_short Multidetector Computed Tomography in Patients with Femoral Neck Fracture for Assessing Osteoporosis: Comparison with Dual Energy X-Ray Absorptiometry
title_sort multidetector computed tomography in patients with femoral neck fracture for assessing osteoporosis: comparison with dual energy x-ray absorptiometry
topic Musculoskeletal Imaging
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9432397/
https://www.ncbi.nlm.nih.gov/pubmed/36237475
http://dx.doi.org/10.3348/jksr.2019.0193
work_keys_str_mv AT multidetectorcomputedtomographyinpatientswithfemoralneckfractureforassessingosteoporosiscomparisonwithdualenergyxrayabsorptiometry
AT multidetectorcomputedtomographyinpatientswithfemoralneckfractureforassessingosteoporosiscomparisonwithdualenergyxrayabsorptiometry